• Title/Summary/Keyword: Local response

Search Result 1,580, Processing Time 0.029 seconds

Mobilizing Voluntary Organizations in Taiwanese Emergency Response: Citizen Engagement and Local Fire Branch Heads

  • Wu, Wei-Ning;Chang, Ssu-Ming;Collins, Brian K.
    • Journal of Contemporary Eastern Asia
    • /
    • v.14 no.2
    • /
    • pp.45-55
    • /
    • 2015
  • This article assesses factors that affect the ability of local fire branch heads in Taiwan to mobilize volunteer organizations in local emergency responses. Data from a survey of local fire branch heads in Taiwan is analyzed by using an OLS model to test three hypotheses regarding the relationship between the dependent variable, perceived ability to mobilize volunteer organizations in emergency response, and three explanatory variables: organizational capacity, quality of communication, and the quality of citizen engagement ex-ante to emergency response. The model indicates a positive relationship between the ability to mobilize volunteer organizations in emergency response, the quality of communications, and the quality of citizen engagement in preparedness. The research suggests that local fire branch heads and volunteer organizations should begin the process of emergency response mobilization in the preparedness stage. The quality of the citizen engagement in preparedness stages should increase the ability of local fire branch managers to mobilize external resources in emergency response.

Seismic response of foundation-mat structure subjected to local uplift

  • El Abbas, Nadia;Khamlichi, Abdellatif;Bezzazi, Mohammed
    • Coupled systems mechanics
    • /
    • v.5 no.4
    • /
    • pp.285-304
    • /
    • 2016
  • The effects of large rotations and p-delta on the dynamic response of a structure subjected to seismic loading and local uplift of its foundation were analyzed in this work. The structure was modeled by an equivalent flexible mat mounted on a rigid foundation that is supported either by a Winkler soil type or a rigid soil. The equations of motion of the system were derived by taking into account the equilibrium of the coupled foundation-mat system where the structure was idealized as a single-degree-of-freedom. The obtained nonlinear coupled system of ordinary differential equations was integrated by using an adequate numerical scheme. A parametric study was performed then in order to evaluate the maximum response of the system as function of the intensity of the earthquake, the slenderness of the structure, the ratio of the mass of the foundation to the mass of the structure. Three cases were considered: (i) local uplift of foundation under large rotation with the p-delta effect, (ii) local uplift of foundation under large rotation without including the p-delta effect, (iii) local uplift of foundation under small rotation. It was found that, in the considered ranges of parameters and for moderate earthquakes, assuming small rotation of foundation under seismic loading can yield more adverse structural response, while the p-delta effect has almost no effect.

Site-response effects on RC buildings isolated by triple concave friction pendulum bearings

  • Ates, Sevket;Yurdakul, Muhammet
    • Computers and Concrete
    • /
    • v.8 no.6
    • /
    • pp.693-715
    • /
    • 2011
  • The main object of this study is to evaluate the seismic response effects on a reinforced concrete building isolated by triple concave friction pendulum (TCFP) bearings. The site-response effects arise from the difference in the local soil conditions at the support points of the buildings. The local soil conditions are, therefore, considered as soft, medium and firm; separately. The results on the responses of the isolated building are compared with those of the non-isolated. The building model used in the time history analysis, which is a two-dimensional and eight-storey reinforced concrete building with and without the seismic isolation bearings and/or the local soil conditions, is composed of two-dimensional moment resisting frames for superstructure and of plane elements featuring plane-stress for substructure. The TCFP bearings for isolating the building are modelled as of a series arrangement of the three single concave friction pendulum (SCFP) bearings. In order to investigate the efficiency of both the seismic isolation bearings and the site-response effects on the buildings, the time history analyses are elaborately conducted. It is noted that the site-response effects are important for the isolated building constructed on soft, medium or firm type local foundation soil. The results of the analysis demonstrate that the site-response has significant effects on the response values of the structure-seismic isolation-foundation soil system.

Error Estimate of Local Vibration for Building Structures Using Substructure Models (부분구조모델을 이용한 건축물의 국부진동해석에서의 오차원인 분석)

  • 안상경;이현수;이동근
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.545-552
    • /
    • 2001
  • Analysis of a structure for vertical vibration requires a lot of computational efforts because large number of degrees of freedom are generally involved in the dynamic response. Especially, when a structure is loaded with local vibration source, it may not be economical to model the whole structure to obtain the responses of specific members located near or far from the sources. In this study, substructure models have been used for analysis of local vibration An analysis of local vibration is performed for the case that the loaded point and the response point are located on the same floor. Other analysis is performed for the case that the loaded point and the response point are located on the different floor. In this case, if only the floors on which loaded and response points are located are modeled, response of substructure model is very different from that of full model. So, there should be a consideration that degrees of freedom of floors in addition to those of loaded and response floors are included to improve results of dynamic analysis. In this study, floors between loaded floor and response floor were modeled so that modeshapes which affect the response are presented well.

  • PDF

Clinical Study on Immediate Response after Acupuncture on Local Acupoints and Distal Acupoints for Neck Pain Patients (경항통 환자에 대한 원위취혈 및 근위취혈의 침치료 직후 효과에 대한 비교 연구)

  • Lee, Hwi-Yong;Song, Beom-Yong;Yook, Tae-Han;Kang, Ji-Sook;Hong, Kwon-Eui
    • Journal of Acupuncture Research
    • /
    • v.25 no.6
    • /
    • pp.183-192
    • /
    • 2008
  • Objectives : The purpose of this study was to compare immediate response after acupuncture on Local Acupoints group and Distal Acupoints group for neck pain patients. Methods : From January 2nd 2008 to August 31th 2008, 10 neck pain patients were divided into 2 groups. One group(test I group) was taken Local Acupoints, and the other group(test II group) was taken Distal Acupoints. To check immediate response and satisfaction of needling, visual analog scale(VAS), range of motion(ROM), clinical evaluation grade and five-point likert scale were used before and after treatment. Results : Both acupuncture therapy showed immediate response and good effect on neck pain. And test I group showed more immediate response than test II group on all categories. Conclusions : Local Acupoints group can be recommended as an immediate and useful therapy to treat neck pain.

  • PDF

A Study on Improvement of Local Government Disaster Management System in Korea - Focused on Strengthening the Disaster Management Capacity of Local Government - (지방자치단체 재난관리체계 개선에 관한 연구 - 지방자치단체의 재난관리 역할 강화를 중심으로 -)

  • Hong, Ji-Wan
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.9
    • /
    • pp.21-30
    • /
    • 2018
  • This study aims for improving the system in Disaster Management of Local Government. In addition, the overall disaster management system was compared to the effectiveness of the disaster prevention system and reliability, and problems and improvement points were derived. The disaster management system in Korea has a structure that promptly investigates and restores damage by a simple procedure. Korea disaster management system manages information on top-down structural disasters through the flow of prevention, preparation, response, and recovery. The process from disaster response to recovery under the leadership of the central disaster safety headquarters is simplified. Disaster management tasks are dispersed among departments, making it difficult to respond promptly. Under the control of the central government, disaster management, such as disaster prevention, investigation, and recovery, are carried out. The disaster management improvement direction of the local government should establish the disaster response system focusing on the local government. Therefore, it is necessary to have budget to operate the organization - centered disaster management budget and the disaster management organization. The disaster response manual should be prepared considering the disaster environment and disaster prevention plan. In order to utilize disaster information, it is necessary to reorganize information system such as integrate and streamline of the private resource database and NDMS.

Research on disaster management personnel improvement measure of local government

  • Young Ran Kim;JungHyun Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.11 no.2
    • /
    • pp.1-9
    • /
    • 2023
  • The purpose of this study is to examine the disaster management system of local governments by diagnosing the current status of disaster management experts in Korea, deriving problems and improvement measures, and looking at local governments' total labor cost system. The status and status of disaster management personnel were compared and analyzed to find ways to improve the local government's disaster management response system under the Framework Act on Disaster and Safety Management in Korea. Considering Korea's reality, because national security and disaster management exist together, we devised a plan to improve on-site response capabilities and seek solutions by deriving the problems of the currently operating security and safety-related organizations.

Influence of exterior joint effect on the inter-story pounding interaction of structures

  • Favvata, Maria J.;Karayannis, Chris G.;Liolios, Asterios A.
    • Structural Engineering and Mechanics
    • /
    • v.33 no.2
    • /
    • pp.113-136
    • /
    • 2009
  • The seismic induced interaction between multistory structures with unequal story heights (inter-story pounding) is studied taking into account the local response of the exterior beam-column joints. Although several parameters that influence the structural pounding have been studied sofar, the role of the joints local inelastic behaviour has not been yet investigated in the literature as key parameter for the pounding problem. Moreover, the influence of the infill panels as an additional parameter for the local damage effect of the joints on the inter-story pounding phenomenon is examined. Thirty six interaction cases between a multistory frame structure and an adjacent shorter and stiffer structure are studied for two different seismic excitations. The results are focused: (a) on the local response of the critical external column of the multistory structure that suffers the hit from the slab of the adjacent shorter structure, and (b) on the local response of the exterior beam-column joints of the multistory structure. Results of this investigation demonstrate that the possible local inelastic response of the exterior joints may be in some cases beneficial for the seismic behaviour of the critical column that suffers the impact. However, in all the examined cases the developing demands for deformation of the exterior joints are substantially increased and severe damages can be observed due to the pounding effect. The presence of the masonry infill panels has also been proved as an important parameter for the response of the exterior beam-column joints and thus for the safety of the building. Nevertheless, in all the examined inter-story pounding cases the presence of the infills was not enough for the total amelioration of the excessive demands for shear and ductility of the column that suffers the impact.

Monotone Local Linear Quasi-Likelihood Response Curve Estimates

  • Park, Dong-Ryeon
    • Communications for Statistical Applications and Methods
    • /
    • v.13 no.2
    • /
    • pp.273-283
    • /
    • 2006
  • In bioassay, the response curve is usually assumed monotone increasing, but its exact form is unknown, so it is very difficult to select the proper functional form for the parametric model. Therefore, we should probably use the nonparametric regression model rather than the parametric model unless we have at least the partial information about the true response curve. However, it is well known that the nonparametric regression estimate is not necessarily monotone. Therefore the monotonizing transformation technique is of course required. In this paper, we compare the finite sample properties of the monotone transformation methods which can be applied to the local linear quasi-likelihood response curve estimate.

The effect of local topography on the seismic response of a coupled train-bridge system

  • Qiao, Hong;Du, Xianting;Xia, He;De Roeck, Guido;Lombaert, Geert;Long, Peiheng
    • Structural Engineering and Mechanics
    • /
    • v.69 no.2
    • /
    • pp.177-191
    • /
    • 2019
  • The local topography has a significant effect on the characteristics of seismic ground motion. This paper investigates the influence of topographic effects on the seismic response of a train-bridge system. A 3-D finite element model with local absorbing boundary conditions is established for the local site. The time histories of seismic ground motion are converted into equivalent loads on the artificial boundary, to obtain the seismic input at the bridge supports. The analysis of the train-bridge system subjected to multi-support seismic excitations is performed, by applying the displacement time histories of the seismic ground motion to the bridge supports. In a case study considering a bridge with a span of 466 m crossing a valley, the seismic response of the train-bridge system is analyzed. The results show that the local topography and the incident angle of seismic waves have a significant effect on the seismic response of the train-bridge system. Leaving these effects out of consideration may lead to unsafe analysis results.