• 제목/요약/키워드: Local blackout

검색결과 8건 처리시간 0.039초

지역급전원을 위한 고장복구 교육시스템 개발 (Development of Power Restoration Training System for Local Operators)

  • 이남호;송인준;박철우;정길조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.105-106
    • /
    • 2006
  • KEPRI has completed to develop KP-ROTS Ver 1.1 and applied to 12 power transmission district offices and Je-ju branch office in KEPCO, which was updated from the exiting power restoration training simulator related to power restoration project. This program has functions such as black-start line analysis for all network blackout, restoration training on wide blackout and simple study on outage plans. KEPCO expects that local operators will train well for restoration procedures against wide blackout by using KP-ROTS.

  • PDF

Imputation Method Using Local Linear Regression Based on Bidirectional k-nearest-components

  • Yonggeol, Lee
    • Journal of information and communication convergence engineering
    • /
    • 제21권1호
    • /
    • pp.62-67
    • /
    • 2023
  • This paper proposes an imputation method using a bidirectional k-nearest components search based local linear regression method. The bidirectional k-nearest-components search method selects components in the dynamic range from the missing points. Unlike the existing methods, which use a fixed-size window, the proposed method can flexibly select adjacent components in an imputation problem. The weight values assigned to the components around the missing points are calculated using local linear regression. The local linear regression method is free from the rank problem in a matrix of dependent variables. In addition, it can calculate the weight values that reflect the data flow in a specific environment, such as a blackout. The original missing values were estimated from a linear combination of the components and their weights. Finally, the estimated value imputes the missing values. In the experimental results, the proposed method outperformed the existing methods when the error between the original data and imputation data was measured using MAE and RMSE.

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.

Identification of hydrogen flammability in steam generator compartment of OPR1000 using MELCOR and CFX codes

  • Jeon, Joongoo;Kim, Yeon Soo;Choi, Wonjun;Kim, Sung Joong
    • Nuclear Engineering and Technology
    • /
    • 제51권8호
    • /
    • pp.1939-1950
    • /
    • 2019
  • The MELCOR code useful for a plant-specific hydrogen risk analysis has inevitable limitations in prediction of a turbulent flow of a hydrogen mixture. To investigate the accuracy of the hydrogen risk analysis by the MELCOR code, results for the turbulent gas behavior at pipe rupture accident were compared with CFX results which were verified by the American National Standard Institute (ANSI) model. The postulated accident scenario was selected to be surge line failure induced by station blackout of an Optimized Power Reactor 1000 MWe (OPR1000). When the surge line failure occurred, the flow out of the surgeline was strongly turbulent, from which the MELCOR code predicted that a substantial amount of hydrogen could be released. Nevertheless, the results indicated nonflammable mixtures owing to the high steam concentration released before the failure. On the other hand, the CFX code solving the three-dimensional fluid dynamics by incorporating the turbulence closure model predicted that the flammable area continuously existed at the jet interface even in the rising hydrogen mixtures. In conclusion, this study confirmed that the MELCOR code, which has limitations in turbulence analysis, could underestimate the existence of local combustible gas at pipe rupture accident. This clear comparison between two codes can contribute to establishing a guideline for computational hydrogen risk analysis.

실시간 디지털 시뮬레이터(Hypersim)을 이용한 이차적 전압제어 제어기 구현 (The realization of secondary voltage controller using real-time digital simulator(Hypersim))

  • 김봉식;서상수;이병준;송인준;신정훈;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.269-271
    • /
    • 2006
  • In power system, the reactive power is closely associated with voltage. In addition Reactive power has localized characteristic. Recently wide area blackout caused by reactive power imbalance. Therefore it is important to control reactive power considering its characteristic. Until now maintenance of system voltage has been controlled by shunt compensation rather than generators. However because of a large time-constant, shunt compensators are difficult to manage disturbances immediately. In addition shunt compensation has discrete characteristic, which make disturbances in system. In this paper we studied the voltage maintenance method of local buses by controlling the reactive power output of a generator which is closely related a load bus in addition the proposed method was verified by test system.

  • PDF

광역정전 예방을 위한 분산형 부하 제어 방안에 대한 연구 (A Study on Decentralized under Voltage Load Shedding Scheme for Preventing Wide-area Black Out)

  • 이윤환
    • 전기학회논문지P
    • /
    • 제63권1호
    • /
    • pp.1-6
    • /
    • 2014
  • An electric power system sometimes fails because of disturbances that occur unexpectedly, such as the uncontrolled loss of load that developed from cascading blackout. Which make stability through a little of under voltage load shedding should work. The development of phasor measurement unit(PMU) makes network supervision possible. The information obtained from PMU is synchronized by global positioning system(GPS). There are many real-time algorithms which are monitoring the voltage stability. This paper presents the study on the VILS(Voltage Instability Load Shedding) using PMU data. This algorithm computes Voltage Stability Margin Index(VSMI) continuously to track the voltage stability margin at local bus level. The VSMI is expressed as active and reactive power. The VSMI is used as an criterion for load shedding. In order to examine the algorithm is effective, applied to KEPCO system.

25MW급 산업용 가스터빈의 저널과 베어링 손상 보수사례에 관한 연구 (A Study on Repair Case of Journal and Bearing Damage for 25MW Industrial Gas Turbine)

  • 김병옥;선경호;이안성
    • 한국유체기계학회 논문집
    • /
    • 제15권6호
    • /
    • pp.64-69
    • /
    • 2012
  • This paper deals with the study on repair case of journal shaft and bearing damage in 25MW industrial gas turbine caused by sudden blackout, operation mistake, and logic abnormal, etc. When a serious accident such as journal and bearing damage in a gas turbine occurs, the domestic local companies having the gas turbine are dependent on manufacturer for all maintenance and repair schedule until now. This case study shows that the damaged gas turbine is normally re-operated itself in domestic by establishing repair schedule in a short period of time, repairing damage journal shaft and tilting pad bearings, and performing rotating test for a reliability check. This paper can be regarded as the important case study of emergency test run experience of the refurbished 25MW gas turbine rotor.

태양 흑점활동이 측위오차에 미치는 영향: 태양폭풍 사례연구 (How sun spot activity affects on positioning accuracy?: Case study of solar storm)

  • 유윤자;조득재;박상현
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2011년도 춘계학술대회
    • /
    • pp.27-28
    • /
    • 2011
  • 태양 흑점수의 증감주기 (약 11년)에 따른 태양폭발 (태양에서의 플레어 현상)은 태양 코로나 물질을 대방출하는 태양폭풍을 야기한다. 미국해양대기청 (NOAA: National Oceanic and Atmospheric Administration)은 태양 흑점활동이 2013년과 2014년 사이에 극대화 될 것이라고 예상했다. 강력한 태양폭풍의 영향이 지구에 미쳤을 경우 인공위성을 이용한 전세계 측위시스템의 교란, 각종 통신수단 및 TV, 라디오 방송 등이 영향을 받을 것으로 예상된다. 실제로 1989년 태양폭풍은 캐나다에서 정전사태를 일으켜 9시간동안 약 600만명이 정전으로 인한 피해를 입은 사례가 있다. 이와 같은 초강력 태양폭풍은 인공위성의 수명을 약 5~10년정도 단축시켰으며 이로 인한 경제적 손실 및 파급효과를 고려하면 액수는 수십조 원에 달할 것으로 예상된다. 최근 2011년 2월 15일 10시 45분경 (지역시)에 발생했던 X급 태양폭발에 의해 발생한 태양폭풍의 영향이 2011년 2월 18일 오전 10시 30분경 우리나라 (보현산 관측소)에서 관측되었다. 본 논문에서는 현재 흑점수가 증가하고 있는 시점에서 2월 18일의 태양폭발 일주일 전후 자기장 데이터를 비교하고, 또한 대전에서 관측한 RINEX 데이터를 이용하여 측위결과를 비교 분석하였다. 태양폭풍이 지구에 도달한 2011년 2월 18일의 자기장 관측 값은 일주일 전후 데이터와 비교하여 Proton이 요동하는 결과를 보였고, 대전지역에서의 측위결과도 태양폭풍 일주일 전후와 비교하여 최대 1m이상의 측위오차를 보였다.

  • PDF