• Title/Summary/Keyword: Local behavior

Search Result 1,794, Processing Time 0.029 seconds

Push-out tests on stud shear connectors with constrained structure of steel-concrete composite beams

  • Qi, Jingjing;Xie, Zuwei;Cao, Hua;Huang, Zhi;Lv, Weirong;Shi, Weihua
    • Structural Engineering and Mechanics
    • /
    • v.83 no.6
    • /
    • pp.789-798
    • /
    • 2022
  • The stud shear connector is the main force transfer member in the steel-concrete composite member, and the mechanical behavior is very complicated in the concrete. The concrete around the stud is subjected to the pry-out local pressure concentration of the stud, which can easily produce splitting mirco-cracks. In order to solve the problem of pry-out local splitting of stud shear connector, a kind of stud shear connector with constraint measure is proposed in this paper. Through the push-out test, the interface shear behavior of the new stud shear connector between steel and concrete flange plate was studied, and the difference between the new stud shear connector and the traditional stud connector was compared. The results show that the stud shear connector with constraint measure can effectively avoid the adverse effect of local pressure splitting by relying on its own constraint measure. The shear stiffness of the interface between steel and concrete flange plates is greatly improved, which provides a theoretical basis for the design of strong connection coefficient of steel-concrete composite structures.

Thermomechanical behavior of Macro and Nano FGM sandwich plates

  • Soumia, Benguediab;Tayeb, Kebir;Fatima Zohra, Kettaf;Ahmed Amine, Daikh;Abdelouahed, Tounsi;Mohamed, Benguediab;Mohamed A., Eltaher
    • Advances in aircraft and spacecraft science
    • /
    • v.10 no.1
    • /
    • pp.83-106
    • /
    • 2023
  • In this work, the static behavior of FGM macro and nano-plates under thermomechanical loading. Equilibrium equations are determined by using virtual work principle and local and non-local theory. The novelty of the current model is using a new displacement field with four variables and a warping function considering the effect of shear. Through this analysis, the considered sandwich FGM macro and nanoplates are a homogeneous core and P-FGM faces, homogeneous faces and an E-FGM core and finally P-FGM faces and an E-FGM core. The analytical solution is obtained by using Navier method. The model is verified with previous published works by other models and very close results are obtained within maximum 1% deviation. The numerical results are performed to present the influence of the various parameters such as, geometric ratios, material index as well as the scale parameters are investigated. The present model can be applicable for sandwich FG plates used in nuclear, aero-space, marine, civil and mechanical applications.

An experimental and numerical study on the local buckling of cold-formed steel castellated I-Beam stiffened with oval castellation

  • S. Prabhakaran;R. Malathy;M. Kasiviswanathan
    • Structural Engineering and Mechanics
    • /
    • v.90 no.2
    • /
    • pp.143-157
    • /
    • 2024
  • Cold-formed steel (CFS) I sections are increasingly being used as load-bearing components in building constructions, and such I sections frequently incorporate web holes to facilitate service installation. The economical and structural advantages of these elements have prompted many researchers to investigate the behavior of such structures. Despite numerous studies on the buckling stability of castellated beams, there is a notable absence of experimental investigation into oval castellated beams with stiffeners. This study examines the local buckling of cold-formed steel castellated I-beams stiffened with oval constellations through experimental and numerical analysis. Four specimens are fabricated with and without stiffeners, including parallel, perpendicular, and intersecting types attached to the web portion of the beam, along with cross stiffeners for the oval-shaped openings at the beam ends. Additionally, a numerical model is developed to predict the behavior of castellated beams with oval openings up to failure, considering both material and geometric nonlinearities. Codal analysis is performed using the North American specification for cold-formed steel AISI S-100 and the Australian/New Zealand design code AS/NZS 4600. The anticipated outcomes from numerical analysis, experimental research, and codal analysis are compared and presented. It will be more helpful to the preliminary designers.

사각튜브의 국부좌굴과 전체좌굴에 관한 연구 I

  • Han, Byeong-Gi;Park, Bong-Hyeon;An, Dae-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.4
    • /
    • pp.887-894
    • /
    • 1998
  • This paper presents the results of analytical invesstigation of the buckling behavior of thin-walled box-section column. Throughout this investigation, the single curve for finding the buckling stress at each effective slenderness ratio is derived by modification of the Rankine's formula. The applicable formula in the small slederness region is derived by considering the inelastic behavior of material. Additionally, the bifurcation criterion(slenderness ratio) which can distinguish between the local and overall buckling mode shapes is suggested by equating the local and overall buckling stresses. The overall buckling formula is closely concurrent with the experiments for the rectangular tubes.

Study on the Prediction of Fatigue Life of Multi-Spot Welded Joints (다점용접이음의 피로수명 예측에 관한 연구)

  • Ju, Seok-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.3
    • /
    • pp.471-478
    • /
    • 2002
  • In real structures, multi-spot welded joints are more frequently used than a single-spot welded joint. Most researches, however, have been focused to a single-spot welded joint until now. In this paper, the fatigue behavior of multi-spot welded joints are investigated using the finite element solutions of the multi-spot welded specimens. The local strain approach is used rather than the stress intensity factor approach to estimate the fatigue life since the former is quite simple and straightforward. It is found that the fatigue behavior of multi-spot welded joints is different from that of single-spot welded joints. The local strain approach is still applicable to multi-spot welded joints.

Finite Element Analysis for Wall Thinned Steam Generator Tubes (감육된 증기발생기 전열관의 유한요소 해석)

  • Seong, K.Y.;Ahn, S.H.;Nam, K.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.3
    • /
    • pp.38-44
    • /
    • 2006
  • Failure assessment of steam generator tube are very important for the integrity of energy plants. In pipes of energy plants, sometimes, the local wall thinning may result from severe erosion-corrosion damage. Recently, the effects of local wall thinning on fracture strength and fracture behavior of piping system have been well studied. In this paper, the elasto-plastic analysis is performed by FE code ANSIS on steam generator tube with wall thinning. We evaluated the failure mode, fracture strength and fracture behavior from FE analysis. It was possible to predict the crack initiation point by estimating true fracture ductility under multi-axial stress conditions at the center of the thinned area.

  • PDF

Local response of W-shaped steel columns under blast loading

  • Lee, Kyungkoo;Kim, Taejin;Kim, Jinkoo
    • Structural Engineering and Mechanics
    • /
    • v.31 no.1
    • /
    • pp.25-38
    • /
    • 2009
  • Local failure of a primary structural component induced by direct air-blast loading may be itself a critical damage and lead to the partial or full collapse of the building. As an extensive research to mitigate blast-induced hazards in steel frame structure, a state-of-art analytical approach or high-fidelity computational nonlinear continuum modeling using computational fluid dynamics was described in this paper. The capability of the approach to produce reasonable blast pressures on a steel wide-flange section column was first evaluated. Parametric studies were conducted to observe the effects of section sizes and boundary conditions on behavior and failure of columns in steel frame structures. This study shows that the analytical approach is reasonable and effective to understand the nature of blast wave and complex interaction between blast loading and steel column behavior.

A Study on the Constitutive Behavior of Undisturbed Weathered Soils at Small-to-Large Strain Conditions (미소변형률 및 대변형률 조건에서 불교란 풍화토의 구성거동에 관한 연구)

  • 오세붕;이영휘;안영대
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.139-146
    • /
    • 2001
  • Undrained triaxial tests were peformed for a weathered soil, which includes local measurement using LVDT The behavior from small In large strain conditions could be evaluated consistently through a triaxial test, The stress-strain relationship of undisturbed samples were compared with the disturbed and the shear moduli in the small strain level had the almost same values. Especially the shear moduli were mostly affected by the initial condition of water contents. An anisotropic hardening model based on the total stress concept could predict the stress-strain relationship accurately, which makes it possible to analyze the geotechnical problem reasonably for the weathered soil.

  • PDF

Fatigue Test and Analysis of Multi-point Spot Welded Joints (다점용접이음의 피로 시험과 해석)

  • Chu, Seok-Jae;Lee, Kwang-Hoo
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.175-180
    • /
    • 2001
  • In real structure, multi-point spot welded joints are more frequently used than a single-point spot welded joint. Most researches, however, have been focused to a single-point spot welded joint until now. In this paper, the fatigue behavior of multi-point spot welded joints are investigated both experimentally and analytically using the finite elements. The local strain approach is used rather than the stress intensity factor approach to estimate the fatigue life since the former is quite simple and straightforward. It is found that the fatigue behavior of multi-point spot welded joints is different from that of single-point spot welded joints. The local strain approach is still applicable to multi-point spot welded joints.

  • PDF

Fabrication and characterization of SILO isolation structure (SILO 구조의 제작 방법과 소자 분리 특성)

  • Choi, Soo-Han;Jang, Tae-Kyong;Kim, Byeong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.328-331
    • /
    • 1988
  • Sealed Interface Local Oxidation (SILO) technology has been investigated using a nitride/oxide/nitride three-layered sandwich structure. P-type silicon substrate was either nitrided by rapid thermal processing, or silicon nitride was deposited by LPCVD method. A three-layered sandwich structure was patterned either by reactive ion etch (RIE) mode or by plasma mode. Sacrificial oxidation conditions were also varied. Physical characterization such as cross-section analysis of field oxide, and electrical characterization such as gate oxide integrity, junction leakage and transistor behavior were carried out. It was found that bird's beak was nearly zero or below 0.1um, and the junction leakages in plasma mode were low compared to devices of the same geometry patterned in RIE mode, and gate oxide integrity and transistor behavior were comparable. Conclusively, SILO process is compatible with conventional local oxidation process.

  • PDF