• Title/Summary/Keyword: Local Temperature Surface Distribution

Search Result 101, Processing Time 0.03 seconds

분무냉각에 의한 강판 열처리과정에 있어서 열전달분포의 측정 (Measurements of Heat Transfer Distribution in Spray Cooling of Hot Steel Plate .)

  • 김영찬;유갑종;서태원
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.886-893
    • /
    • 2000
  • A good understanding of the heat transfer distribution is very important to suppress the deformation of steel products. In this study, the local heat transfer coefficients are experimentally investigated to understand the heat transfer distribution of thick steel plates with even flat spray nozzle. The steel slabs are cooled down from the initial temperature of about $1000^{\circ}C$ , and the local heat transfer coefficients and surface temperatures are calculated from the measured temperature-time history. The results show that the local heat transfer coefficients of spray cooling are dominated by the local droplet flow rate, and in proportion to becoming more distant from the center of heat transfer surface, the local heat transfer coefficients decrease with the decrease of the local droplet flow rate.

  • PDF

고밀도 도시기후관측 망 자료를 이용한 대구의 여름철 기온 수평 공간 분포의 일변화 (Diurnal Variations in the Horizontal Temperature Distribution using the High Density Urban Climate Observation Network of Daegu in Summer)

  • 김상현;김백조;김해동
    • 한국환경과학회지
    • /
    • 제25권2호
    • /
    • pp.259-265
    • /
    • 2016
  • We analyzed diurnal variations in the surface air temperature using the high density urban climate observation network of Daegu in summer, 2013. We compared the time elements, which are characterized by the diurnal variation of surface air temperature. The warming and cooling rates in rural areas are faster than in urban areas. It is mainly due to the difference of surface heat capacity. In addition, local wind circulation also affects the discrepancy of thermal spatiotemporal distribution in Daegu. Namely, the valley and mountain breezes affect diurnal variation of horizontal distribution of air temperature. During daytimes, the air(valley breeze) flows up from urban located at lowlands to higher altitudes of rural areas. The temperature of valley breeze rises gradually as it flows from lowland to upland. Hence the difference of air temperature decreases between urban and rural areas. At nighttime, the mountains cool more rapidly than do low-lying areas, so the air(mountain breeze) becomes denser and sinks toward the valleys(lowlands). As the result, the air temperature becomes lower in rural areas than in urban areas.

GRID/GIS 및 RS 자료를 이용한 에너지 평형 모형으로부터의 국지적 지표 온도 산출 (Estimation of Local Surface Temperature from EBM with the Use of GRID/GIS and Remote Sensed data)

  • 신선희;하경자;김재환;오현미;조명희
    • 대한원격탐사학회지
    • /
    • 제20권2호
    • /
    • pp.103-116
    • /
    • 2004
  • 지표 온도를 산출하는 중규모 대기 모형은 일반적으로 태양 복사의 직달 일사량에 대하여 경사진 지형의 효과를 고려하지 않는다. 이는 실제 태양 복사량의 국지적 차이를 나타내지 못하며, 그 결과 국지적인 지표 온도에서의 큰 오차를 가져온다. 따라서 지형의 기하학적 특성뿐만 아니라 지표의 식생 특성을 고려함으로써, 정확한 국지적 지표 온도를 나타내고자 하였다. 본 연구의 목적은 GIS의 그리드 모형을 적용한 에너지 균형 모형(EBM)을 사용하여 진단적으로 지역적 지표 온도를 산출하는 것이다. 본 연구에서, 한반도 남부 지역의 지형적 비균질성은 그리드 내의 지형 방위각과 경사각의 함수인 조도각의 항으로써 흡수된 지표 일사량 계산에 고려되었다. 또한 지표 온도 변화에 주요한 변수가 되는 지표의 식생 특성이 NDVI의 항으로 사용하였다. 지표의 경사진 지형의 효과와 식생 특성이 고려된 지표 온도의 상세한 지역적 분포가 연구 결과로써 제시되었다. 이러한 지역적 지표 온도 분포는 저층 대기에서 지형에 의한 지역 순환을 형성할 수 있으며, 실제 자연에서의 지역 순환을 더욱 잘 설명할 수 있을 것이다.

Solar Insolation Effect on the Local Distribution of Lunar Hydroxyl

  • Kim, Suyeon;Yi, Yu;Hong, Ik-Seon;Sohn, Jongdae
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권1호
    • /
    • pp.47-54
    • /
    • 2018
  • Moon mineralogy mapper ($M^3$)'s work proved that the moon is not completely dry but has some hydroxyl/water. $M^{3{\prime}}s$ data confirmed that the amount of hydroxyl on the lunar surface is inversely related to the measured signal brightness, suggesting the lunar surface is sensitive to temperature by solar insolation. We tested the effect of solar insolation on the local distribution of hydroxyl by using $M^3$ data, and we found that most craters had more hydroxyl in shade areas than in sunlit areas. This means that the local distribution of hydroxyl is absolutely influenced by the amount of sunshine. We investigated the factors affecting differences in hydroxyl; we found that the higher the latitude, the larger the difference during daytime. We also measured the pyroxene content and found that pyroxene affects the amount of hydroxyl, but it does not affect the difference in hydroxyl between sunlit and shaded areas. Therefore, we confirmed that solar insolation plays a significant role in the local distribution of hydroxyl, regardless of surface composition.

Leidenfrost 온도 이상의 가열 벽면과 충돌 시 열전달에 대한 액적 온도의 영향 (Effects of Droplet Temperature on Heat Transfer During Collision on a Heated Wall Above the Leidenfrost Temperature)

  • 박준석;김형대
    • 한국분무공학회지
    • /
    • 제21권2호
    • /
    • pp.78-87
    • /
    • 2016
  • This study experimentally investigated the effects of droplet temperature on the heat transfer characteristics during collision of a single droplet on a heated wall above the Leidenfrost temperature. Experiments were performed by varying temperature from 40 to $100^{\circ}C$ while the collision velocity and wall temperature were maintained constant at 0.7 m/s at $500^{\circ}C$, respectively. Evolution of temperature distribution at the droplet-wall interface as well as collision dynamics of the droplet were simultaneously recorded using synchronized high-speed video and infrared cameras. The local heat flux distribution at the collision surface was deduced using the measured temperature distribution data. Various physical parameters, including residence time, local heat flux distribution, heat transfer rate, heat transfer effectiveness and vapor film thickness, were measured from the visualization data. The results showed that increase in droplet temperature reduces the residence time and increases the vapor film thickness. This ultimately results in reduction in the total heat transfer by conduction through the vapor film during droplet-wall collision.

Forced Convection Boiling Heat Transfer from a Horizontal Cylinder to Subcooled Water

  • Lee, Sung-Hong;Lee, Euk-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.79-90
    • /
    • 1999
  • This investigation presents the experimental results of forced convection boiling heat transfer around a circular, electrically heated horizontal cylinder to subcooled water in cross flow. In these experiments, the following primary variables were included: heat flux, flow velocity, pressure and degree of subcooling at inlet. Local surface temperatures were measured at nine peripheral positions. Local surface temperature distributions are classified into four categories depending on the supplied heat flux. The effects of the boiling curve depending on the fluid velocity, degree of subcooling at inlet and pressure are presented.

  • PDF

원관 주위의 대류 열전달에 대한 복합 열전달 (Conjugated heat transfer on convection heat transfer from a circular tube in cross flow)

  • 이승홍;이억수;정은행
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.523-534
    • /
    • 1998
  • The convection heat transfer on horizontal circular tube is studied as a conjugated heat transfer problem. With uniform heat generation in a cylindrical heater placed in a cross flow boundary condition, heat flow that is conducted along the wall of the heater creates a non-isothermal surface temperature and non-uniform heat flux distribution. In the present investigation, the effects of circumferential wall heat conduction on convection heat transfer are investigated for the case of forced convection around horizontal circular tube in cross flow of air and water. Non-dimensional conjugation parameter $ K^*$ which can be deduced from the governing energy differential equation should be used to express the effect of circumferential wall heat conduction. Two-dimensional temperature distribution$ T({\gamma,\theta})$ is presented. The influence of circumferential wall heat conduction is demonstrated on graph of local Nusselt number.

  • PDF

열교환기 휜에서의 서리층 두께와 서리층 표면온도의 실험 상관식 (Empirical Correlations of Frost Thickness and Frost Surface Temperature on Heat Exchanger Fin)

  • 김경민;김정수;김장현;이관수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.798-803
    • /
    • 2009
  • In this study, dimensionless correlations of frost properties (i.e. the thickness and surface temperature of frost) on heat exchanger fin with nonuniform temperature distribution are proposed from frosting experiments. We analyzed the local fin temperature distribution, frost thickness and frost surface temperature on a 2D fin; in the airflow direction and the direction perpendicular to airflow. As a result, the frost growth on the fin had a close relation with fin heat conduction. The dimensionless correlations for the average frost properties were expressed as a function of dimensionless temperature, humidity ratio, Reynolds number, and Fourier number. These correlations agreed well with experimental data with the error less than 14%.

  • PDF

도시 대기 중 유기염소계 살충제의 농도수준 및 배출 특성 (Atmospheric Concentrations and Temperature- Dependent Air-Surface Exchange of Organochlorine Pesticides in Seoul)

  • 최민규;여현구;천만영;선우영
    • 한국대기환경학회지
    • /
    • 제18권4호
    • /
    • pp.275-284
    • /
    • 2002
  • Atmospheric concentrations of organochlorine pesticides (OCPs) in Seoul, South Korea between July 1999 and May 2000 were determined to investigate concentration distribution in air, relationship between concentrations and meteorological conditions, and apportionment of sources e.g. local sources (air- surface exchange) and long range transport. Endosulfan and $\alpha$-HCH were the highest concentrations in atmosphere with values typcally ranging from 10s to l00s of pg/㎥. These high concentrations may be attributed to their usage, period and chemical property (Koa). All OCPs also showed elevated levels during the summer and were positively correlated with temperature. This would suggest that a seasonal enhancement was due to (re)volatilization from secondary sources and application during the warmer months. The temperature dependence of atmospheric concentrations of OCPs were investigated using plots of the natural logarithm of partial pressure (In P) vs reciprocal mean temperatures (1/T), and environmental phase-transition energies were calculated for each of the pesticides. For OCPs, temperature dependence was statistically significant (at the 99.99% confidence level) and temperature accounted for 35~95% of the variability in concentrations. The relatively higher slopes and phase-transition energies for $\alpha$-, ${\gamma}$-chlordane, endosulfan and endosulfan sulfate suggested that volatilization from local sources influenced their concentrations. The relatively lower those for $\alpha$-, ${\gamma}$-HCH, p, p'-DDE and heptachlor epoxide also suggested that volatilization from local sources and long range transport influenced their concentrations.

지표 특성 변화에 대한 평형온도의 반응 연구 : EBM 연구 (On response of Surface Equilibrium Temperature for Change of Surface Characteristics : An EBM Study)

  • 서예원;추정은;하경자
    • 한국제4기학회지
    • /
    • 제24권2호
    • /
    • pp.1-11
    • /
    • 2010
  • 지표 특성 차이에 따라 외부강제력에 대한 차별적인 반응을 보이는 지표 평형온도 분포를 실험하기 위해 에너지 균형 모형(Energy Balance Model, EBM)이 사용되었다. EBM은 입사되는 복사에너지가 각 위도별로 수송되는 에너지와 방출되는 복사에너지의 합과 균형을 이루었을 때의 온도를 산출한다. 지구의 에너지 원천인 태양복사에너지를 전지구 에너지 균형에 있어 중요하게 취급하기 위하여 위도별 알베도 변화뿐만 아니라 해륙의 분포 차이에 따른 에너지 균형을 고려한 지구 평형온도 분포에 관한 실험이 수행되었으며, 입사되는 태양복사에너지량을 강제력으로 하여 위도별 알베도의 선형적인 증감, 극지역 알베도의 5%, 10%, 15% 증감에 대한 반응, 극과 중위도 지역에서의 상반된 증감에 대한 반응을 실험하였다. 그리고 얼음-알베도 피드백의 유무에 대한 실험도 수행되었다. 극지역의 알베도를 증가시키면 입사되는 태양에너지를 차단시켜 위도별 열수송을 감소시키는데 이는 극지역을 저에너지 상태로 유지시킴으로써 저위도에서부터의 에너지 수송을 강화시킨다. 이러한 수송량의 차이로 인해 중위도 지역의 온도 변화는 극지역에 비해 크게 나타난다. 육지는 해양에 비해 열용량이 작기 때문에 평형온도에 도달하는 시간이 짧으며 알베도에 따른 온도변화에 민감하여 해양과의 온도차이를 유발시킨다. 따라서 평형온도는 지표가 가지는 특성인 알베도와 열용량의 차이에 따라 다르게 나타나며 알베도가 증가함에 따라 감소하고 열용량이 작을수록 변화율이 큰 특징이 있다. 얼음-알베도 피드백은 알베도의 선형적인 증가에 따른 지구 평형온도의 감소를 가속화시키지만 국지적으로는 비선형적인 감소를 보인다.

  • PDF