• 제목/요약/키워드: Local Nu distribution

검색결과 13건 처리시간 0.021초

마이크로채널에서의 국소 열전달 측정 (Local heat transfer measurement inside microchannel)

  • 조대관;이준식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1902-1907
    • /
    • 2008
  • The current work presents a design and fabrication technique for a microchannel system to measure the local temperature distribution inside microchannel. This micro channel system fabricated by MEMS technique is integrated with a heater and an array of temperature sensors so that detailed heat transfer phenomena inside micro-scale channel can be studied. Materials widely used in semiconductor process were selected to fabricate a heater and temperature sensors on a silicon wafer. On these heater and sensors a channel wall was fabricated with SU-8. The friction constant and the local Nusselt number distribution measured for the deionized water flow in the microchannel is presented.

  • PDF

Vibrational Relaxation and Fragmentation in Icosahedral (Ar2+)Ar12 Clusters

  • Ree, Jongbaik;Kim, Yoo Hang;Shin, Hyung Kyu
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권9호
    • /
    • pp.2774-2780
    • /
    • 2014
  • A dynamics study of relaxation and fragmentation of icosahedral argon cluster with a vibrationally excited $Ar_2^+$ (${\nu}$) is presented. Local translation is shown to be responsible for inducing energy flow from the embedded ion to host atoms and fragmentation of the cluster consisting of various low frequency modes. The total potential energy of $(Ar_2^+)Ar_{12}$ is formulated using a building-up procedure of host-guest and host-host interactions. The time dependence of ion-to-host energy transfer is found to be tri-exponential, with the short-time process of ~100 ps contributing most to the overall relaxation process. Relaxation timescales are weakly dependent on both temperature (50-300 K) and initial vibrational excitation (${\nu}$ = 1-4). Nearly 27% of host atoms in the cluster with $Ar_2^+$ (${\nu}$ = 1) fragment immediately after energy flow, the extent increasing to ~43% for ${\nu}$ = 4. The distribution of fragmentation products of $(Ar_2^+)Ar_{12}{\rightarrow}(Ar_2^+)Ar_n+(12-n)Ar$ are peaked around $(Ar_2^+)Ar_8$. The distribution of dissociation times reveals fragmentation from one hemisphere dominates that from the other. This effect is attributed to the initial fragmentation causing a sequential perturbation of adjacent atoms on the same icosahedral five-atom layer.

수평 직사각 덕트 내 임계점 부근 물의 대류열전달 특성 (Convective Heat Transfer to Water near the Critical Region in Horizontal Rectangular Ducts)

  • 이상호
    • 대한기계학회논문집B
    • /
    • 제36권5호
    • /
    • pp.477-485
    • /
    • 2012
  • 수평 덕트 내 임계점부근의 유체 유동 및 열전달특성은 중력과 함께 임계영역에서의 열역학 및 전달 물성치의 많은 변화와 직접적으로 연관되어 있다. 본 연구에서는 수평 직사각 덕트 내 임계점부근의 물에 대한 대류열전달특성을 전산해석을 통하여 분석하였다. 이를 통해 국부적인 열전달계수와 유속, 온도, 그리고 물성치분포를 포함한 대류열전달특성에 대해 임계점 근접효과와 함께 비교하였다. 벽으로부터의 열전달에 따른 유체 밀도감소로 덕트 내 유동방향으로의 유속증가와 함께 유체가 액체에서 기체 같은 상태로 천이하는 형태의 유동장특성을 보여준다. 덕트의 윗면, 옆면, 그리고 아래면 각각의 국부적인 열전달계수분포에 큰 차이가 있으며 준임계점 온도부근에서 난류전달특성의 향상으로 열전달계수의 최대치에 이르게 된다. Nu 수는 덕트 내 압력과 종횡비에 영향을 받으며 임계압에 가까워질수록 최대 Nu 수는 급격히 증가하게 된다. 이와 함께 기존의 열전달상관식을 통한 결과와 예측된 Nu 수 분포를 비교하였다.

An Investigation of Heat Transfer Characteristics of Swirling Flow in a 180$^{\circ}$ Circular Section Bend with Uniform Heat Flux

  • Chang, Tae-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제17권10호
    • /
    • pp.1520-1532
    • /
    • 2003
  • An experiment was performed to obtain the local heat transfer coefficient and Nusselt number in a circular duct with a 180$^{\circ}$ bend for Re=6 x 10$^4$, 8 x 10$^4$ and 1 x 10$\^$5/ under swirling flow and non-swirling flow conditions. The test tube with a circular section was made from stainless steel having a curvature ration of 9.4. Current heat flux of 5.11 kW/㎡ was applied to the test tube by electrical power and the swirling motion of air was produced by a tangential inlet to the pipe axis at 180$^{\circ}$. Measurements of local wall temperatures and the bulk mean temperatures of air were made at four circumferential positions at 16 stations. The wall temperatures showed a reduced distribution curve at the bend for the non-swirling flow, but this effect did not appear for the swirling flow. The Nusselt number distributions for the swirling flow, which was calculated from the measured wall and the bulk temperatures, were higher than that of the non-swirling flow. The average Nusselt number of the swirling flow increased by about 90-100%, compared to that of the non-swirling flow. The Nu/Nu$\_$DB/ values at the 90$^{\circ}$ station for non-swirling flow and swirling flow were approximately 2.5 and 4.8 at Re=6x10$^4$ respectively. The values agree well with Said's results for non-swirling flow.

충돌수분류(衝突水噴流)에 의한 Semi-cylinder면(面)에서의 열전달(熱傳達)에 관(關)한 실험적(實驗的) 연구(硏究) (An Experimental Study on Heat Transfer of Semi-cylindrical Surface by Impinging Water Jet)

  • 염기찬;최국광;서정윤
    • 대한설비공학회지:설비저널
    • /
    • 제17권6호
    • /
    • pp.708-716
    • /
    • 1988
  • Local heat transfer coefficients were measured on semi-cylinders on which a circular water jet impinged in crossflow. The ratio of the semi-cylinder's diameter and the nozzle outlet diameter were varied parametrically, as were the Reynolds number and the supplementary water heights. The measurements showed that the circumferential distribution of the heat transfer coefficient peaked at the stagnation point. For a fixed supplementary water height, the peak heat transfer coefficient was not depend on the curvature of test specimen(d/D). Optimum height of supplementary water which brought about the augmentation of heat transfer at the stagnation point was S/D=1. The Nusselt number decreased as the circumferential distance or angle increased. The circumferential distribution of dimensionless heat transfer (Nu/Nus) was independent of d/D ($d/D{\geq}8.33$), but for the d/D<8.33, it was depended on d/D. At a fixed angle of specimen, dimensionless heat transfer (Nu/Nus) decreased as the ratio d/D increased. The extent of the decrease between d/D=6.67 and 8.33 was markedly greater than that between d/D=8.33 and 10, or d/D=10 and 11.67.

  • PDF

역유동계산법을 이용한 국소배기효율의 수치해석 (Numerical analysis of local exhaust effectiveness using reverse-flow calculation method)

  • 한화택
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.658-665
    • /
    • 1998
  • This paper investigates local exhaust effectiveness in a room with a supply and an exhaust slots on the ceiling. The mean age of air is an indicator of supply effectiveness, while the mean residual life time can be used as an indicator of exhaust effectiveness. The distribution of local mean residual life time in a space is calculated by four different numerical procedures. The reverse-flow calculation method has been proved to show quite accurate results while it can save considerable amount of computation time and efforts, compared to the method by its original definition. It is concluded that the diffusion term in the equation of mean residual life time can be neglected. The spatial and temporal diffusion characteristics of the contaminant are also discussed.

  • PDF

발포 알루미늄이 삽입된 환형관에서의 압력손실 및 강제대류 열전달 (Pressure Loss and Forced Convective Heat Transfer in an Annulus Filled with Aluminum Foam)

  • 노주석;이계복;이충구
    • 설비공학논문집
    • /
    • 제17권9호
    • /
    • pp.855-862
    • /
    • 2005
  • An experimental investigation has been carried out for aluminum foam heat sink inserted into the annulus to examine the feasibility as a heat sink for high performance forced water cooling in the annulus. The local wall temperature distribution, inlet and outlet pressures and temperatures, and heat transfer coefficients were measured for heat flux of 13.6, 18.9, 25.1, 31.4 $kw/m^2$ and Reynolds number ranged from 120 to 2000. Experimental results show that the friction factor is higher than clear annulus without aluminum foam, while the significant augmentation in Nu is obtained. This technique can be used for the compactness of the heat exchanger.

바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향 (Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space)

  • 정광섭;한화택;홍승재
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

Steiner Tree 이론을 이용한 우편물 교환센터인 최적 워치선정 (Optimal Location of Mail Distribution Center using Steiner Tree)

  • 양성덕;유웅규;이상중
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.82-87
    • /
    • 2008
  • 국내 택배시장은 과거 몇 개의 업체에서 독점해왔으나 현재는 대기업들과 수많은 중소기업들이 참여하고 있어 경쟁이 심화되고 있다. 우편물의 신속한 배송과 운송비용의 최소화는 매우 중요하며 이를 위하여 운송거리의 최단 거리화가 우선 필요하다. 본 논문은 전국의 주요 도시에 배치된 우편집중국을 기하적으로 가장 짧게 연결하는 교환 센터의 최적 위치를 찾는 방법을 제시한다. 송전계통의 routing, 배전선로망의 최적화 등에 이용되고 있는 Steiner Tree이론을 최단거리 우편물 운송망 구축에 적용하였다. Steiner Tree이론으로부터 선정된 위치에 교환센터를 설치할 경우, 운송비를 절감하여 경영수지를 개선할 뿐 아니라 신속한 배달을 최우선으로 하는 택배 시장에서 우위를 점할 수 있을 것으로 기대된다. Steiner Tree 이론은 차기 초고압 선로를 최단거리로 연결하는 전력소의 위치선정 등에도 활용될 수 있을 것으로 사료된다.

균일 열플럭스가 있는 $180^{\circ}C$ 원형단면 곡관의 선회유동 열전달특성 연구 (A study on the heat transfer characteristics of swirling flow in a circular sectioned $180^{\circ}C$bend with uniform heat flux)

  • 이상배;권기린;장태현
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.615-627
    • /
    • 1997
  • An experiment was performed to local heat transfer coefficient and Nusselt number in the circular duct of 180.deg. bend for Re=6*10$^{4}$, 8*10$^{4}$ and 1*10$^{5}$ at swirling flow and non-swirling flow conditions. The test tube with circular section was made by stainless which has curvature ratio 9.4. The wall of test tube was heated directly by electrical power to 3.51 kw and swirling motion of air was produced by a tangential inlet to the pipe axis at the 180 degree. Measurements of local wall temperatures and bulk mean temperature of air are made at four circumferential positions in the 16 stations. The wall temperatures show particularly reduced distribution curve at bend for non-swirling flow but this effect does not appear for swirling flow. Nusselt number distributions for swirling flow which was calculated from the measured wall and bulk temperatures were higher than that of non-swirling flow. Average Nusselt number of swirling flow increased about 90 ~ 100% than that of non-swirling flow whole through the test tube. The Nu/N $u_{DB}$ values at the station of 90.deg. for non-swirling flow and swirling flow are respectively about 2.5 and 4.8 at Re=6*10$^{4}$. Also that is good agreement with Said's result for non-swirling flow. flow.