• 제목/요약/키워드: Local Extraction

검색결과 547건 처리시간 0.027초

Local anesthesia for mandibular third molar extraction

  • Kim, Chang;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제18권5호
    • /
    • pp.287-294
    • /
    • 2018
  • Mandibular third molar extraction is commonly performed in dental clinics. However, the optimal method of anesthesia has not been established for this procedure. The conventional inferior alveolar nerve block is the most widely used method. However, its success rate is not high and it may lead to complications, such as aspiration and nerve injury. Therefore, various anesthesia methods are being investigated. Articaine has been proven to be efficacious in a number of studies and is being used with increasing frequency in clinical practice. In this review article, we will briefly review various local anesthesia techniques, anesthetics, and a computer-controlled local anesthetic delivery (CCLAD) system, which reduces pain by controlling the speed of drug injection, for mandibular third molar extraction.

콩 품종에 따른 고형분, 단백질, 색소의 추출 특성의 비교 (Comparison Study of Extraction Properties of Solids, Protein and Color Pigments of Several Soybean Varieties)

  • 김동희;김석동;김우정
    • Applied Biological Chemistry
    • /
    • 제33권1호
    • /
    • pp.8-13
    • /
    • 1990
  • 우리나라에서 생산되는 장려품종 중 팔달, 단엽, 장백, 백운, 장엽콩과 재래종 중 검정콩, 갈색아주까리콩 등 7품종을 대상으로 형태적 특성과 표피의 색, 고형분 및 단백질의 추출 수율, 콩의 색소용출속도 등을 조사하였다. 그 결과 콩 개체의 무게는 갈색아주까리콩이 가장 높고 단엽, 장백이 가장 낮은 값을 보였다. 표피의 색에서는 'L'값은 장백이 가장 높았으며 팔달, 백운, 장엽, 단엽 등도 비교적 높은 'L'값을 나타내었다. 'a', 'b'값에서는 장엽이 높았고 검정콩과 갈색아주까리콩이 비교적 낮은 'b'값을 보였다. 콩을 마쇄하여 물로 추출할 때 고형분과 단백질의 수율은 3회까지 대부분이 추출되었으며 이때 이들의 수율은 각각 73.2 %, 83.2 %이었다. 콩 표피의 색소의 용출은 추출온도와 시간에 따라 큰 영향을 받았다. 평형에 도달한 흡광도(A)와 추출온도(T)와의 관계는 A=aT+b의 관계로 표시할 수 있었으며, 색소용출 속도와 온도와의 관계는 $60^{\circ}C$를 중심으로 두개의 직선관계가 있었다. 이 관계에서 계산된 활성화에너지는 고온보다 저온이 더 높았고, Local 1과 Local 2가 가장 높은 활성화에너지 값을 보여 주었다.

  • PDF

CLASSIFIED ELGEN BLOCK: LOCAL FEATURE EXTRACTION AND IMAGE MATCHING ALGORITHM

  • Hochul Shin;Kim, Seong-Dae
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.2108-2111
    • /
    • 2003
  • This paper introduces a new local feature extraction method and image matching method for the localization and classification of targets. Proposed method is based on the block-by-block projection associated with directional pattern of blocks. Each pattern has its own eigen-vertors called as CEBs(Classified Eigen-Blocks). Also proposed block-based image matching method is robust to translation and occlusion. Performance of proposed feature extraction and matching method is verified by the face localization and FLIR-vehicle-image classification test.

  • PDF

Risk factors of osteonecrosis of the jaw after tooth extraction in osteoporotic patients on oral bisphosphonates

  • Jeong, Ho-Gul;Hwang, Jae Joon;Lee, Jeong-Hee;Kim, Young Hyun;Na, Ji Yeon;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • 제47권1호
    • /
    • pp.45-50
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the incidence of bisphosphonate-related osteonecrosis of the jaw (BRONJ) after tooth extraction in patients with osteoporosis on oral bisphosphonates in Korea and to evaluate local factors affecting the development of BRONJ. Materials and Methods: The clinical records of 320 patients who underwent dental extraction while receiving oral bisphosphonates were reviewed. All patients had a healing period of more than 6 months following the extractions. Each patient's clinical record was used to assess the incidence of BRONJ; if BRONJ occurred, a further radiographic investigation was carried out to obtain a more definitive diagnosis. Various local factors including age, gender, extraction site, drug type, duration of administration, and C-terminal telopeptide (CTx) level were retrieved from the patients' clinical records for evaluating their effect on the incidence of BRONJ. Results: Among the 320 osteoporotic patients who underwent tooth extraction, 11 developed BRONJ, reflecting an incidence rate of 3.44%. Out of the local factors that may affect the incidence of BRONJ, gender, drug type, and CTx level showed no statistically significant effects, while statistically significant associations were found for age, extraction site, and duration of administration. The incidence of BRONJ increased with age, was greater in the mandible than the maxilla, and was associated with a duration of administration of more than 3 years. Conclusion: Tooth extraction in patients on oral bisphosphonates requires careful consideration of their age, the extraction site, and the duration of administration, and close postoperative follow-up should be carried out to facilitate effective early management.

자성 비드를 이용한 소형 유전자 추출기의 자동제어 시스템의 설계 및 구현 (Automatic Control System Design and Implementation for a Miniaturized DNA Extraction System using Magnetic Beads)

  • 김상호;김종대;김희찬;김종원
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권4호
    • /
    • pp.311-317
    • /
    • 2009
  • An automatic control system is proposed and implemented for a miniaturized DNA extraction system using magnetic bead. A host-local system is employed for the accommodation of the graphical user interface and the basic control function. The functional partitioning into the local and the host system is discussed. The control functions are classified and formalized for the flexible control scenario, which is the input of the proposed system. As the proposed scenario is consists of the sequence of the user-centric actions, the user goal can be easily programmed and modified. The DNA extraction performance of the implemented system was compared with the existing silica-membrane-based method, resulting in the comparable concentration and purity of the extracted DNA. The proposed system is currently being utilized for the development of the DNA extraction system only changing scenario, without any alteration of the system.

국소 극대-극소점 간의 간격정보를 이용한 시간영역에서의 음성인식을 위한 파라미터 추출 방법 (A Time-Domain Parameter Extraction Method for Speech Recognition using the Local Peak-to-Peak Interval Information)

  • 임재열;김형일;안수길
    • 전자공학회논문지B
    • /
    • 제31B권2호
    • /
    • pp.28-34
    • /
    • 1994
  • In this paper, a new time-domain parameter extraction method for speech recognition is proposed. The suggested emthod is based on the fact that the local peak-to-peak interval, i.e., the interval between maxima and minima of speech waveform is closely related to the frequency component of the speech signal. The parameterization is achieved by a sort of filter bank technique in the time domain. To test the proposed parameter extraction emthod, an isolated word recognizer based on Vector Quantization and Hidden Markov Model was constructed. As a test material, 22 words spoken by ten males were used and the recognition rate of 92.9% was obtained. This result leads to the conclusion that the new parameter extraction method can be used for speech recognition system. Since the proposed method is processed in the time domain, the real-time parameter extraction can be implemented in the class of personal computer equipped onlu with an A/D converter without any DSP board.

  • PDF

Evaluation of Bleeding After Denal Extraction in Patients Taking Single Antiplatelet Treatment

  • Kim, Jae Jin;Kim, Hak Kyun
    • International Journal of Oral Biology
    • /
    • 제40권3호
    • /
    • pp.147-150
    • /
    • 2015
  • The purpose of this study was to evaluate the effect of single antiplatelet treatment on delayed bleeding, in patients undergoing dental extraction. A total of 154 teeth were extracted in 94 patients with ongoing antiplatelet treatment, who were taking single antiplatelet of either aspirin or clopidogrel. All patients underwent simple dental extraction; local hemostasis was performed with gauze-biting, suturing, and/or application of a local hemostatic agent. Delayed bleeding was recorded in 5 teeth out of a total of 154 teeth after extraction, the incidence of postoperative delayed bleeding being 3.2%. The bleeding was controlled by the patients themselves, through application of pressure with additional gauze-biting. No one visited the doctor or emergency room for hemostasis. These results confirmed that patients taking single antiplatelet drugs may have teeth extracted safely without interruption of the antiplatelet treatment.

Visual Attention Detection By Adaptive Non-Local Filter

  • Anh, Dao Nam
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권1호
    • /
    • pp.49-54
    • /
    • 2016
  • Regarding global and local factors of a set of features, a given single image or multiple images is a common approach in image processing. This paper introduces an application of an adaptive version of non-local filter whose original version searches non-local similarity for removing noise. Since most images involve texture partner in both foreground and background, extraction of signified regions with texture is a challenging task. Aiming to the detection of visual attention regions for images with texture, we present the contrast analysis of image patches located in a whole image but not nearby with assistance of the adaptive filter for estimation of non-local divergence. The method allows extraction of signified regions with texture of images of wild life. Experimental results for a benchmark demonstrate the ability of the proposed method to deal with the mentioned challenge.

제 3대구치 발치 후 발생한 돌발성 난청: 증례보고 및 문헌 고찰 (Sudden sensorineural hearing loss after third molar extraction: Case report and literature review)

  • 김형기;김일형;구정귀;노민호
    • 대한치과의사협회지
    • /
    • 제58권7호
    • /
    • pp.404-411
    • /
    • 2020
  • This study reports the unusual complications of 22-year-old male who presented with sudden hearing loss after the right mandibular third molar extraction under local anesthesia with 3.6 ml of 2 % lidocaine. Total 8.75 mg of oral dexamethasone for 1 week immediately after extraction was prescribed in department of oral and maxillofacial surgery but hearing did not improve after 1 week. As referral to otolaryngology, total 600 mg of oral methylon and hyperbaric oxygen therapies were operated for 2 weeks. The hearing of patient was improved at 6 weeks after extraction but tinnitus was persisted even after 12 months. The reason and treatment were discussed with literature review, searching with the keywords ['hearing loss' AND ('dental' OR 'tooth extraction'OR'teeth extraction')] in PubMed and Google scholar at October 2019. Total five cases were reported after tooth extraction with local anesthesia. The sudden hearing loss could be associated with local anesthesia containing vasoconstrictors. Early steroid (extensive medication and intra-tympanic injection) and hyperbaric oxygen therapies were recommended within 2 weeks. As a proper treatment, hearing could be improved but other additional symptoms, such as tinnitus, dizziness, might be remained.

  • PDF

Anesthetic efficacy and safety of 2% lidocaine hydrochloride with 1:100,000 adrenaline and 4% articaine hydrochloride with 1:100,000 adrenaline as a single buccal injection in the extraction of maxillary premolars for orthodontic purposes

  • Deshpande, Nupoor;Jadhav, Anendd;Bhola, Nitin;Gupta, Manan
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권4호
    • /
    • pp.233-240
    • /
    • 2020
  • Background: Palatal injection of local anesthetics is the most painful injection. To obviate the need for palatal injections, local anesthetic agents with diffusibility are being investigated. Hence the present study was designed to analyze the anesthetic efficacy of 2% lidocaine hydrochloride (HCl) with 1:100,000 adrenaline and 4% articaine hydrochloride (HCl) with 1:100,000 adrenaline using single buccal infiltration for the extraction of maxillary premolars. Methods: A prospective, double-blind, crossover, randomized clinical study was performed on 60 consecutive systemically healthy patients with an age range of 15-30 years, requiring extraction of asymptomatic bilateral maxillary premolars for orthodontic purposes. They received 1ml buccal infiltration of 4% articaine HCl with 1:100,000 adrenaline on one side and 2% lidocaine HCl with 1:100,000 adrenaline on the other side. The extraction procedure on either side was scheduled 14 days apart. Parameters assessed were the time of onset of anesthesia, intraoperative discomfort, hemodynamic parameters, and the duration of analgesia. Analysis of the data was done using the Mann-Whitney test, the Wilcoxon test, the Kruskal-Wallis ANOVA test, and the chi-square test. Statistical significance was established at P < 0.05. Results: Articaine showed a faster time of onset and longer duration of analgesia than lidocaine. However, the difference in the intraoperative discomfort and hemodynamic parameters was statistically insignificant. Conclusion: Within the limitations of the study, it can be concluded that the extraction of maxillary premolars can be performed with a single buccal infiltration of 2% lidocaine HCl with 1:100,000 adrenaline, which is one of the most commonly used local anesthetic agent.