• Title/Summary/Keyword: Local Air Ventilation

Search Result 112, Processing Time 0.024 seconds

Numerical Analysis on Hood Shape Improvement of Local Ventilation System (국소환기시스템의 후드형상 개선에 따른 수치해석)

  • Yi, Chung-Seub;Jang, Sung-Cheol;Choi, Joo-Hong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.260-265
    • /
    • 2009
  • The aim of this study is to remove crack on a ventilation device at the suction part of zinc plating factory, and the main point is making optimum configuration by improving an existing hood system. The result shows that existing hood system has problem with duct configuration, angle and reducer. Model-5 shows lowest pressure difference as meaning of suction capability. The hood inlet surface has most uniform suction capability.

CFD analysis of ventilation efficiency around an elevated highway using visitation frequency and purging flow rate

  • Huang, Hong;Kato, Shinsuke;Ooka, Ryozo;Jiang, Taifeng
    • Wind and Structures
    • /
    • v.9 no.4
    • /
    • pp.297-313
    • /
    • 2006
  • The concentration of air pollution along roads is higher than the surrounding area because ventilation efficiency has decreased due to the high-density use of space along roads in recent years. In this study, ventilation efficiency around a heavily traffic road covered by an elevated highway and hemmed in along its side by buildings is evaluated using Visitation Frequency (VF, the frequency for pollutant to return to the objective domain) and Purging Flow Rate (PFR, the air flow rate for defining the local domain-averaged concentration). These are analyzed using Computational Fluid Dynamics (CFD) based on the standard $k-{\varepsilon}$ model. The VF and PFR characteristics of four objective domains are analyzed in terms of the changes in wind direction and arrangements of the fencing dividing up and down direction in the road center under the elevated highway. The resulting VFs are more than 1.0 for all cases, which means that pollutants return to the objective domain restricted by the elevated highway and side buildings. The influence of the arrangement of the buildings around the objective domain and the structure in the domain on the VF is substantial. In cases where there are no obstacles under the elevated highway, the local air exchange rate in the domain tends to be improved. Using these indices, the urban ventilation efficiencies between different urban areas can be compared easily.

Comparison of age of air and air change effectiveness between supply diffuser types (공조취출방식에 따른 공기의 나이 및 환기효율 비교)

  • Cho, D.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

A Study on Application of Distributor for Duct Design at House Ventilation System (주택용 환기시스템의 덕트설계를 위한 분배기 적용성 검토)

  • Yee, Jurng-Jae;Choi, Seok-Yong;Kim, Seok-Keun;Kim, Kwang-Hyun;Lee, Young-Woo;Kim, Hwan-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.770-775
    • /
    • 2007
  • Although these days application of heat recovery ventilation and improved kitchen ventilation system came into wide use in mixed-use residential buildings and exclusive residences, there are not enough ventilation systems except the local ventilation of kitchens and rest rooms. It is very important part to regulate and distribute correct air flow rate for controlling air change rate. The purpose of this study is to investigate the application of distributor at house ventilation system by comparing a duct system with out distributor and with distributor. The results of this study are as follows. (1) When using distributor though the size of duct diameter is reduced rapidly, the pressure loss doesn't rise largely. The pressure loss without distributor is 4.08 mmAq, the pressure loss with distributor 4.10 mmAq. (2) To use distributor can reduce materials of duct and secure enough ceiling space by reducing duct diameter. (3) Diameters and air flow paths of distributor on the design stage are important part for accurate air flow rate.

Organic Solvent Exposure of Thinner-Using Occupation and Its Treatment by Means of $TiO_2$ Photocatalyst (신너사용 작업장의 유기용제 노출 및 $TiO_2$ 광촉매를 이용한 BTX처리에 관한 연구)

  • 양원호;김현용;손부순;박종안
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.26-33
    • /
    • 2002
  • Ultimate objective of industrial hygiene is the prevention of health impairment that may result from exposure to chemicals at workplace. Workers in solvent thinner-using occupation environment may be highly exposed to VOCs (volatile organic compounds) because solvent thinner has been used extensively such as painting, spraying, degreasing, coating and so on in Korea. The purpose of this study was to recognize, evaluate, and propose the control methods of VOCs from solvent thinner-using workplace. Five target volatile organic compounds (benzene, toluene, ethylbenzene, o-xylene, and m-xylene) were monitored in H company of Shiwa Industrial Complex and analyzed in perosnal, occupational indoor and outdoor during working hours simultaneously. Engineering control such as local ventilation should be made in considering the long-term exposure, though measured VOCs concentration did not exceed the workplace exposure standards. In addition, air cleaning device should be installed in local ventilation because Shiwa Industrial Complex has had the serious ambient air pollution. Currently, environmental purification using $TiO_2$ photocatalyst have attracted a great deal of attention with increasing number of recent environmental problems. In this study, $TiO_2$ sol coated on the ceramic bead was prepared by sol-gel method and the photodegradation of target compounds was investigated in gas phase by the exposure to UV-A lamp(365nm) in a batch system.

Numerical Simulation on the Wind Ventilation Lane and Air Pollutants Transport due to Local Circulation Winds in Daegu Districts (대구지역의 국지순환풍의 환기경로 및 대기오염수송에 관한 수치모의)

  • Koo, Hyun-Suk;Kim, Hae-Dong
    • Journal of the Korean earth science society
    • /
    • v.25 no.6
    • /
    • pp.418-427
    • /
    • 2004
  • Recently, urban planning with consideration of urban climate, represented by the concept of urban ventilation lane is widely practiced in many countries. The concept of urban ventilation lane is mainly aimed to improve the thermal comfort within urban area in summer season. It has also the aim to reduce the urban air pollution by natural cold air drainage flows which are to be intensified by a suitable alignment of buildings as well as use zonings based on scientific reasons. In this study, the prevailing wind ventilation lane of a local wind circulation and around Daegu for a typical summer days was investigated by using a numerical simulation. The transport of air pollutants by the local circulation winds was also investigated by using the numerical simulation model, the RAMS (Reasonal Atmospheric Model System).The domain of interest is the vicinity of Daegu metropolitan city (about 900 km2). The horizontal scale of the area is about 30 km. The simulations were conducted under a late spring synoptic condition with weak gradient wind and almost clear sky. From the numerical experiment, the following three conclusions were obtained: (1) The major wind passages of the local circulation wind generated by radiative cooling over the representative mountains of Daegu (Mt. Palgong and Mt. Ap) were found. The winds blow down along the valley axis over the eastern part of Daegu as a gravity flow during nighttime. (2) At the flatland, the winds blow toward the western part of Daegu through the city center. (3) As the results, the air pollutants were transported toward the western part of Daegu by the winds during nighttime.

A Practical usage of industrial local ventilation facility and energy saving in the industrial ventilation (산업용 국소환기장치 활용 및 공장환기의 에너지절약)

  • 심광진;이동호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.28 no.6
    • /
    • pp.433-442
    • /
    • 1999
  • 기원전 27세기경, 고대 이집트의 피라미드건설을 위해 앗시리아 지방에서 나일강변으로 이주한 기술자들의 집합주택에는 거의 환기구가 설치되어 있었다는 기록이 있다. 이 환기방법은 실내와 실외의 기온차에 의한 공기의 부력을 이용한 중력환기로 생각된다. 중력환기는 지금도 주물공장 등의 고온, 발열을 수반하는 작업장에서 적용되고 있으며, 이와 같이 자연력을 이용한 환기를 자연환기라 부른다.

  • PDF

Development of CFD model for Predicting Ventilation Rate based on Age of Air Theory using Thermal Distribution Data in Pig House (돈사 내부 열환경 분포의 공기연령 이론법 적용을 통한 전산유체역학 환기 예측 모델 개발)

  • Kim, Rack-woo;Lee, In-bok;Ha, Tae-hwan;Yeo, Uk-hyeon;Lee, Sang-yeon;Lee, Min-hyung;Park, Gwan-yong;Kim, Jun-gyu
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.6
    • /
    • pp.61-71
    • /
    • 2017
  • The tracer gas method has an advantage that can estimate total and local ventilation rate by tracing air flow. However, the field measurement using tracer gas has disadvantages such as danger, inefficiency, and high cost. Therefore, the aim of this study was to evaluate ventilation rate in pig house by using the thermal distribution data rather than tracer gas. Especially, LMA (Local Mean Age), which is an index based on the age of air theory, was used to evaluate the ventilation rate in pig house. Firstly, the field experiment was conducted to measure micro-climate inside pig house, such as the air temperature, $CO_2$ concentration and wind velocity. And then, LMA was calculated based on the decay of $CO_2$ concentration and air temperature, respectively. This study compared between LMA determined by $CO_2$ concentration and air temperature; the average error and root mean square error were 3.76 s and 5.34 s. From these results, it was determined that thermal distribution data could be used for estimation of LMA. Finally, CFD (Computational fluid dynamic) model was validated using LMA and wind velocity. The mesh size was designed to be 0.1 m based on the grid independence test, and the Standard $k-{\omega}$ model was eventually chosen as the proper turbulence model. The developed CFD model was highly appropriate for evaluating the ventilation rate in pig house.

A Study on the ventilation Technology for Indoor Air Quality Improvement (실내 공기질 개선을 위한 환기기술에 관한 연구)

  • Chang Tae-Hyun;Cho Hyun-Wook
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.540-551
    • /
    • 2005
  • In this research, We'll focus on warm environment and ventilation characteristics when utilizing intake ports, exhaust port and 4-way cassettes for removing heat and polluted air. Four way cassettes have been typical air conditioning units for offices since the multi air-conditioner was introduced. The following installation cases will also be discussed: 1) 4-way cassette's operation without intake ports and exhaust port. 2) Effect of the position of intake port and exhaust ports. 3) cooling air flow, temperature. distribution and local supply index according to the air flow rate from 4-way cassettes.