• 제목/요약/키워드: Loading rates

검색결과 577건 처리시간 0.023초

Dynamic bending behaviours of RC beams under monotonic loading with variable rates

  • Xiao, Shiyun;Li, Jianbo;Mo, Yi-Lung
    • Computers and Concrete
    • /
    • 제20권3호
    • /
    • pp.339-350
    • /
    • 2017
  • Dynamic behaviours of reinforced concrete (RC) bending beams subjected to monotonic loading with different loading rates were studied. A dynamic experiment was carried out with the electro-hydraulic servo system manufactured by MTS (Mechanical Testing and Simulation) Systems Corporation to study the effect of loading rates on the mechanical behaviours of RC beams. The monotonic displacement control loading, with loading rates of 0.1 mm/s, 0.5 mm/s, 1 mm/s, 5 mm/s and 10 mm/s, was imposed. According to the test results, the effects of loading rates on the failure model and load-displacement curve of RC beams were investigated. The influences of loading rates on the cracking, ultimate, yield and failure strengths and displacements, ductility and dissipated energy capability of RC beams were studied. Then, the three-dimensional finite element models of RC beams, with the rate-dependent DP (Drucker-Prager) model of concrete and three rate-dependent model of steel reinforcement, were described and verified using the experimental results. Finally, the dynamic mechanical behaviours and deformation behaviours of the numerical results were compared with those of the experimental results.

열가소성 복합재료의 응력완화 모델링 (Modeling the Relaxation Behavior of a Polymeric Composite)

  • 김위대
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2000년도 춘계학술발표대회 논문집
    • /
    • pp.76-79
    • /
    • 2000
  • Polymeric composites exhibit highly nonlinear and rate dependent behavior during loading and unloading in off-axis directions. The equilibrium state of stress during loading is lower than the state of stress produced at finite strain rates. The amount of stress relaxation during loading decreases. Interestingly, however, the stress goes up to reach to the equilibrium state of stress for a fixed displacement during unloading. The unloading behavior is quite similar to the loading behavior. The stress relaxation patterns during loading and unloading is also similar, and those depend on the fiber orientation angles and the loading and unloading rates. The AS4/PEEK thermoplastic composite is used to characterize the relaxation behavior for different off-axis angles and loading rates. There exists a transient loading region at the beginning of unloading. The effective stress and effective plastic strain concept is used to establish a master curve of stress recovery pattern for different off-axis angles and unloading rates.

  • PDF

낙동강 지류·지천 모니터링 결과를 이용한 수질환경 평가 (Water Quality Analysis in Nakdong River Tributaries)

  • 임태효;손영규
    • 한국환경과학회지
    • /
    • 제25권12호
    • /
    • pp.1661-1671
    • /
    • 2016
  • Water quality in Nakdong river was analyzed using 699 monitoring data sets including flow rates and water quality concentrations collected at 195 tributary monitoring stations (the priority management areas: 35 stations, the non-priority management areas: 160 stations) in 2015. The highest average concentrations of all data for BOD, COD, T-N, T-P, SS, and TOC were 30~600 times higher than the lowest concentrations while the highest average loading rates were 800,000~2,700,000 times higher than the lowest loading rates. Because of the very large differences in the concentrations and loading rates, the variation of the concentrations and loading rates in a priority management monitoring station for BOD, T-P, and TOC was analyzed using the coefficient of variation, the ratio of the standard deviation value to the mean value. For BOD, T-P, and TOC, the coefficients of variation for concentration were mostly less than 100%, whereas the coefficients of variation for loading rate ranged from 31.1% to 232.2%. The very big difference in the loading rates was due to the large variation in flow rates. As a result of this, the estimation of water quality at each monitoring station using the average values of the concentrations and loading rates might be not rational in terms of their representativeness. In this study, new water quality analysis methods using all collected monitoring data were suggested and applied according to the water quality standard in medium-sized management areas.

해수 조건에서 총암모니아성 질소 부하량과 수리학적 공기 부하량에 따른 유동상 여과조의 질산화 성능 평가 (Nitrification Performance of a Moving Bed Bioreactor (MBBR) at Different Ammonia and Hydraulic Air-Loading Rates under Seawater Conditions)

  • 이재건;이영훈;박정환
    • 한국수산과학회지
    • /
    • 제56권6호
    • /
    • pp.870-877
    • /
    • 2023
  • The purpose of this study was to assess the efficiency of nitrification based on ammonia loading rates and hydraulic air-loading rates in a moving bed bioreactor (MBBR) under seawater conditions. The goal was to provide foundational data for the design of these bio reactors. At an ammonia loading rate of 0.2 g TAN·m-2 surface area·day-1, the influent TAN concentration was determined to be 1.76±0.33 mg·L-1, which is below the safe concentration for fish survival (2 mg·L-1). Considering operational aspects, the optimal ammonia-loading rate was derived. Subsequently, experimental results for nitrification efficiency at the optimal ammonia-loading rate revealed that the optimum hydraulic air-loading rate was 1.8 L·air·m-2 surface area·min-1. This condition resulted in the lowest concentrations of TAN and NO2-N in the influent water, thus establishing the optimal hydraulic air-loading rate. A regression equation was derived for the ammonia-removal rate (Y) based on the ammonia-loading rate (x) and expressed as a 0.5-order equation (Y=ax0.5+b). Specifically, for TAN concentrations of 0-6 mg·L-1, the regression equation Y=0.1683x0.5-0.13628, was established.

Organic Matter and Hydraulic Loading Effects on Nitrification Performance in Fixed Film Biofilters with Different Filter Media

  • Peng, Lei;Oh, Sung-Yong;Jo, Jae-Yoon
    • Ocean and Polar Research
    • /
    • 제25권3호
    • /
    • pp.277-286
    • /
    • 2003
  • Nitrification performance of fixed film biofilters using coarse sand, loess bead, or styrofoam beads in biofilter columns 1 meter high and 30cm in diameter were studied at different hydraulic and organic matter loading rates. Synthetic wastewater was supplied to the culture tank in order to maintain desired TAN concentrations in inlet water to biofilters. All the biofilters were conditioned 5 months before start of sampling. TAN and $NO_2-N$ conversion rates increased with an increase in the hydraulic loading rate (HLR). However, the improvement in biofilter performance was not linearly correlated to HLR in styrofoam bead filters. This is mainly due to the characteristics of the styrofoam beads used. TAN conversion rates of sand filters increased with the increase of HLR up to $200m^3/m^2$. per day. No increase in the TAN conversion rate was observed at the highest HLR since flooding on the media surface took place. HLR had a significant impact on the TAN conversion rates in loess bead filter up to the highest HLR tested (P<0.05). TAN conversion rates were much less at organic matter loading rates of 9 and 18kg $O_2/m^3$ per day than those without the addition of organic matter in styrofoam bead filters. The addition of glucose resulted in a reduction of the TAN conversion rate from 540 to 284g $TAN/m^3$ per day. No significant difference of TAN conversion rates between the two organic matter loading rates was found (p<0.05). This indicates that the impact of organic matter on nitrification becomes less and less sensitive with an increase in the COD/TAN ratio. At an organic matter loading rate of 9kg $O_2/m^3$. per day, a great reduction of TAN conversion rates was observed in sand filters and loess bead filters. Clearly, organic matter can be one of the most Important Impacting factors on nitrification. $NO_2-N$ conversion rates showed a similar trend for TAN. Based on the TAN and nitrite conversion rates, styrofoam beads showed the best performance among the three filter media tested. Also, the low gravity and price of styrofoam beads make the handling easier and more cost-effective for commercial application. The results obtained at the highest organic matter loading rates can be used in the biofilter design in recirculating aquaculture system.

Simulation of material failure behavior under different loading rates using molecular dynamics

  • Kim, Kunhwi;Lim, Jihoon;Kim, Juwhan;Lim, Yun Mook
    • Structural Engineering and Mechanics
    • /
    • 제30권2호
    • /
    • pp.177-190
    • /
    • 2008
  • Material failure behavior is generally dependent on loading rate. Especially in brittle and quasi-brittle materials, rate dependent material behavior can be significant. Empirical formulations are often used to predict the rate dependency, but such methods depend on extensive experimental works and are limited by practical constraints of physical testing. Numerical simulation can be an effective means for extracting knowledge about rate dependent behavior and for complementing the results obtained by testing. In this paper, the failure behavior of a brittle material under different loading rates is simulated by molecular dynamics analysis. A notched specimen is modeled by sub-million particles with a normalization scheme. Lennard-Jones potential is used to describe the interparticle force. Numerical simulations are performed with six different loading rates in a direct tensile test, where the loading velocity is normalized to the ratio of the pseudo-sonic speed. As a consequence, dynamic features are achieved from the numerical experiments. Remarkable failure characteristics, such as crack surface interaction/crack arrest, branching, and void nucleation, vary in case of the six loading cases. These characteristics are interpreted by the energy concept approach. This study provides insight into the change in dynamic failure mechanism under different loading rates.

Characteristics of Pressure Confined Concrete under Monotonic Compression

  • Rhim, Hong-Chul;Buyukozturk, Oral;Soon, K. A;Kim, Gwang-Ho
    • KCI Concrete Journal
    • /
    • 제13권1호
    • /
    • pp.53-60
    • /
    • 2001
  • Tests of cylindrical concrete specimens under lateral confining pressure of up to 5,000 psi were conducted for two different axial loading cases: monotonic compression and monotonic tension. The purpose of this experimental investigation is to provide stress-strain characteristics of plain concrete in triaxial stress conditions. Lateral confining pressure levels, loading rates, and strength of concrete specimens are varied as parameters. The loading rates are $34.75$\times$10^{-5}$ in/in/sec for fast, $\times$$6.95x10^{-5}$ in/in/sec for normal. and $0.579$\times$10^{-5}$ in/in/sec for slow loading cases. The concrete specimens used in the experiment have compressive strength of 3,500 psi and 6,500 psi, respectively. Findings of this experiment include dependency of the stress-strain behavior of concrete on the above parameters under two different types of loading conditions. The parametric study includes a series of 106 triaxial tests.

  • PDF

회전매체를 가진 완전혼합 활성슬러지/Solid Contact 공법을 이용한 하수처리에 관한 연구 (Sewage Treatment using Moving Media Complete Mixing Activated Sludge/Solid Contact Process)

  • 김홍태
    • 한국농공학회지
    • /
    • 제35권4호
    • /
    • pp.67-75
    • /
    • 1993
  • This study was carried out to investigate the applicability of Solid Contact Process for the improvement of Moving Media Complete Mixing Activated Sludge(MMCMAS) effluents. Laboratory MMCMAS Reactor and MMCMAS/Solid Contact were operated at the hydraulic loading of 122~340 L/m$^2$/d. The conclusions from this study were as follows ; The addition of Solid Contact tank to the MMCMAS reactor has increased the SCOD and SBOD removal efficiencies of 4 to 67% and 2 to 41%, respectively. In addition, the increments of nitrification rates were about 13 to 46%. It was also observed that the addition of Solid Contact tank has greatly increased the organic removal efficiencies at the higher hydraulic loading rates and also decrement of sludge production rates was 0.1 gVSS/gBODrem. It was therefore concluded that the addition of Solid Contact tank could have polished the effluent of MMCMAS at the higher hydraulic loading rates.

  • PDF

다양한 전계인가율과 온도에서 강유전 세라믹의 이력선도 계측과 기준 잔류 분극 및 변형률 거동 예측 (Measured Polarization Hysteresis and Predicted Reference Remnant Polarization and Strains of Ferroelectric Ceramics at Various Electric Field Loading Rates and Temperatures)

  • 지대원;김상주
    • 한국세라믹학회지
    • /
    • 제51권6호
    • /
    • pp.591-597
    • /
    • 2014
  • A poled lead zirconate titanate (PZT) rectangular parallelepiped specimen was subjected to through-thickness electric fields at five loading rates and four temperatures. The rates of the electric field were 0.01, 0.10, 0.25, 0.50, and $1.00MVm^{-1}s^{-1}$; the temperatures were 20, 50, 80, and $110^{\circ}C$. From the measured polarization hysteresis responses, the so-called reference remnant polarization and strains were calculated. Using the calculated reference remnant polarization hysteresis loops, the effects of loading rates and temperature were discussed; using the calculated reference remnant strains, strain butterfly loops were calculated and compared with observations.

재하속도를 이용한 중간토의 지지력 평가 (Relationships of Loading Rates and Bearing Capacities on Intermediate Soils)

  • 박중배
    • 한국지반공학회지:지반
    • /
    • 제12권4호
    • /
    • pp.101-114
    • /
    • 1996
  • 본 연구는 중간토의 지지력 및 변형특성을 조사하기 위해 원심재하장치(centrifuge)를 이용한 지지력 실험을 시행한 결과이다. 점성토에 비해 투수계수가 비교적 큰 중간토지 반을 대상으로 재하 과정에서 발생하는 배수현상이 지반의 지지력에 미치는 영향을 조사하였다. 그 결과, 재하 속도와 지반의 투수계수와의 관계, 즉 본 연구에서 정의한 상대재하속도와 하중강도의 관계로부터 기존 설계상의 문제점을 지적하였고, 또한 재하속도의 차이에 의해 동일 침하량비에서의 하중강도의 대소관계가 역전하는 현상은 비 배수상태의 재하속도 의존성 뿐만 아니라 재하초기부터 발생하는 부분배수현상에 의한 것임을 재하중에 관측한 과잉간극수압의 거동과 변형거동을 중심으로 증명하였다. 나아가 중간토지반에 있어서 기초폭과 초기 지반응력 상태가 지지력에 미치는 영향을 조사하기 위하여 기초폭과 과압밀비를 변화시켜 중간토지반의 지지력 특성을 조사 하였다.

  • PDF