• 제목/요약/키워드: Load-transfer mechanism

검색결과 218건 처리시간 0.022초

기존 시스템 환경에서의 병렬 미디어 서버의 설계 및 구현 (Design and Implementation of parallel Media server in current system environment)

  • 김경훈;류재상;김서균;남지승
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(3)
    • /
    • pp.97-100
    • /
    • 2000
  • As network resources have become faster and demands for multimedia service through network have increased, the demand for Media server system has increased. These kinds of media server solve their bottle neck problem of internal storage device by using parallel system which takes advantage of fast network resource. Many vendors have suggested each of their media server system to solve these problem radically, but most of them require major modification of infra component and additional drawback has added. For example, storage mechanism for specific media requires new file system which is totally different from traditional one, and algorithm for enhancing performance may not suit for traditional operating system environment. In this paper, we designed a parallel media server based on web interface of traditional system and implemented a program for media server. Implemented server system performs parallel processing through web interface without any modification of traditional system, and controls which is related to merging load by distributed data is charged only to client and control server and consequently load of storage server can be minimized. And also, data transfer protocol for streaming media includes Retransfer algorithm and client Admission control policy relevant to performance of whole system.

  • PDF

다양한 마이크로쓰레드(Micro thread)의 개수를 가지는 임플란트의 상부구조물 형상과 하중조건에 따른 3차원 유한요소해석을 이용한 하악골의 응력분포에 관한 연구 (Three-dimensional Stress Analysis of Implant Systems with Micro Threads in the Maxillary Bone)

  • 신하식;한종현;이수홍;전흥재
    • 한국정밀공학회지
    • /
    • 제22권3호
    • /
    • pp.179-186
    • /
    • 2005
  • A comparative study of stress distributions in the maxillary bone with three different types of abutment was conducted. Finite element analysis was adopted to determine stress generated in the bone with the different implant systems with micro threads (Onebody type implant, Internal type implant, and External type implant). It was found that the types of abutments and the number of micro threads have significant influence on the stress distribution in the maxillary bone. They were due to the difference in the load transfer mechanism and the size of contact area between abutment and fixture. Also the maximum effective stress in the maxillary bone was increased with increasing inclination angle of load. It was concluded that the maximum effective stress in the bone was the lowest by the internal implant among the maximum effective stresses by other two types of implants and by appropriate number of micro threads, and that the specific number of micro thread was existed to decrease the maximum effective stress in the maxillary bone due to different implant systems and loading conditions.

Experimental and analytical evaluation of a low-cost seismic retrofitting method for masonry-infilled non-ductile RC frames

  • Srechai, Jarun;Leelataviwat, Sutat;Wongkaew, Arnon;Lukkunaprasit, Panitan
    • Earthquakes and Structures
    • /
    • 제12권6호
    • /
    • pp.699-712
    • /
    • 2017
  • This study evaluates the effectiveness of a newly developed retrofitting scheme for masonry-infilled non-ductile RC frames experimentally and by numerical simulation. The technique focuses on modifying the load path and yield mechanism of the infilled frame to enhance the ductility. A vertical gap between the column and the infill panel was strategically introduced so that no shear force is directly transferred to the column. Steel brackets and small vertical steel members were then provided to transfer the interactive forces between the RC frame and the masonry panel. Wire meshes and high-strength mortar were provided in areas with high stress concentration and in the panel to further reduce damage. Cyclic load tests on a large-scale specimen of a single-bay, single-story, masonry-infilled RC frame were carried out. Based on those tests, the retrofitting scheme provided significant improvement, especially in terms of ductility enhancement. All retrofitted specimens clearly exhibited much better performances than those stipulated in building standards for masonry-infilled structures. A macro-scale computer model based on a diagonal-strut concept was also developed for predicting the global behavior of the retrofitted masonry-infilled frames. This proposed model was effectively used to evaluate the global responses of the test specimens with acceptable accuracy, especially in terms of strength, stiffness and damage condition.

반구형 및 반타원형으로 텍스처링된 평면 베어링의 부하지지능력과 등가마찰계수에 대한 해석 (A Study on the Load Carrying Capacity and Equivalence Friction Coefficient of a Textured Plane Bearing with Semi-spherical Dimples and Semi-ellipsoidal Dimples)

  • 이수영;김필기;석종혁;석종원
    • 한국생산제조학회지
    • /
    • 제21권5호
    • /
    • pp.741-746
    • /
    • 2012
  • The increase of energetic efficiency in plane bearing is getting more important in the transfer mechanism of semi-conductor and display panel manufacturing processes. To accomplish this objective, the technique of surface texturing on bearing surface has recently emerged as one of the most effective candidates. In this study, the effects of various pattern parameters on two bearing performance indices(load carrying capacity and effective friction coefficient) are investigated through a semi-analytic method, i.e., the 2-dimensional Reynolds equation incorporated into the finite difference scheme. Here, cavitation effect is also taken into account by employing an appropriate numerical scheme. In this study, the patterns in the textured surface are composed of a series of semi-spheres or semi-ellipsoids in shape. The effects of their size and number density on the performance indices are examined through the performance of various numerical experiments. Also, the effects of the anisotropy of the semi-ellipsoidal pattern on the bearing's lubrication characteristics are investigated and discussed.

An interface model for the analysis of the compressive behaviour of RC columns strengthened by steel jackets

  • Minafo, Giovanni
    • Structural Engineering and Mechanics
    • /
    • 제71권3호
    • /
    • pp.233-244
    • /
    • 2019
  • Steel jacketing technique is a retrofitting method often employed for static and seismic strengthening of existing reinforced concrete columns. When no continuity is given to angle chords as they cross the floor, the jacket is considered "indirectly loaded", which means that the load acting on the column is transferred partially to the external jacket through interface shear stresses. The evaluation of load transfer mechanism between core and jacket is not straightforward to be modeled, due to the absence of knowledge of a proper constitutive law of the concrete-to-steel interface and to the difficulties in taking into account the mechanical nonlinearities of materials. This paper presents an incremental analytical/numerical approach for evaluating the compressive response of RC columns strengthened with indirectly loaded jackets. The approach allows calculating shear stresses at the interface between core and jacket and predicting the axial capacity of retrofitted columns. A proper constitutive law is proposed for modelling the interaction between the steel and the concrete. Based on plasticity rules and the non-linear behaviour of materials, the column is divided into portions. After a detailed parametric analysis, comparisons are finally made by theoretical predictions and experimental results available in the literature, showing a good agreement.

Detection of flaw in steel anchor-concrete composite using high-frequency wave characteristics

  • Rao, Rajanikant;Sasmal, Saptarshi
    • Steel and Composite Structures
    • /
    • 제31권4호
    • /
    • pp.341-359
    • /
    • 2019
  • Non-monolithic concrete structural connections are commonly used both in new constructions and retrofitted structures where anchors are used for connections. Often, flaws are present in anchor system due to poor workmanship and deterioration; and methods available to check the quality of the composite system afterward are very limited. In case of presence of flaw, load transfer mechanism inside the anchor system is severely disturbed, and the load carrying capacity drops drastically. This raises the question of safety of the entire structural system. The present study proposes a wave propagation technique to assess the integrity of the anchor system. A chemical anchor (embedded in concrete) composite system comprising of three materials viz., steel (anchor), polymer (adhesive) and concrete (base) is considered for carrying out the wave propagation studies. Piezoelectric transducers (PZTs) affixed to the anchor head is used for actuation and the PZTs affixed to the surrounding concrete surface of the concrete-anchor system are used for sensing the propagated wave through the anchor interface to concrete. Experimentally validated finite element model is used to investigate three types of composite chemical anchor systems. Studies on the influence of geometry, material properties of the medium and their distribution, and the flaw types on the wave signals are carried out. Temporal energy of through time domain differentiation is found as a promising technique for identifying the flaws in the multi-layered composite system. The present study shows a unique procedure for monitoring of inaccessible but crucial locations of structures by using wave signals without baseline information.

Tensile capacity of mortar-filled rectangular tube with various connection details

  • Kim, Chul-Goo;Kang, Su-Min;Eom, Tae-Sung;Baek, Jang-Woon
    • Steel and Composite Structures
    • /
    • 제44권3호
    • /
    • pp.339-351
    • /
    • 2022
  • A mortar-filled rectangular hollow structural section (RHS) can increase a structural section property as well as a compressive buckling capacity of a RHS member. In this study, the tensile performance of newly developed mortar-filled RHS members was experimentally evaluated with various connection details. The major test parameters were the type of end connections, the thickness of cap plates and shear plates, the use of stud bolts, and penetrating bars. The test results showed that the welded T-end connection experienced a brittle weld fracture at the welded connection, whereas the tensile performance of the T-end connection was improved by additional stud bolts inserted into the mortar within the RHS tube. For the end connection using shear plates and penetrating stud bolts, ductile behavior of the RHS tube was achieved after yielding. The penetrating bars increased load carrying capacity of the RHS. Based on the analysis of the load transfer mechanism, the current design code and test results were compared to evaluate the tensile capacity of the RHS tube according to the connection details. Design considerations for the connections of the mortar-filled RHS tubes were also recommended.

Structural performance of an electricity tower under extreme loading using the applied element method- A case study

  • Chin, Jason Ah;Garcia, Mauricio;Cote, Jeffrey;Mulcahy, Ellen;Clarke, Jonathan;Elshaer, Ahmed
    • Wind and Structures
    • /
    • 제34권3호
    • /
    • pp.313-319
    • /
    • 2022
  • The resiliency of electricity transmission and distribution lines towards natural and man-made hazards is critical to the operation of cities and businesses. The extension of these lines throughout the country increases their risk of extreme loading conditions. This paper investigates a unique extreme loading condition of a 100-year old distribution line segment that passes across a river and got entangled with a boom of a ship. The study adopts the Applied Elements Method (AEM) for simulating 54 cases of the highly deformable structural behaviour of the tower. The most significant effects on the tower's structural integrity were found to occur when applying the load with components in all three of the cartesian directions (i.e., X, Y and Z) with the full capacities of the four cables. The studied extreme loading condition was determined to be within the tower's structural capacity, attributed to the shear failure of the anchor bolts, which acted as a sacrificing element that fails to protect the transfer of tensioning load to the supporting tower.

Seismic behavior of thin-walled CFST pier-to-base connections with tube confined RC encasement

  • Xuanding Wang;Yue Liao;Jiepeng Liu;Ligui Yang;Xuhong Zhou
    • Steel and Composite Structures
    • /
    • 제50권2호
    • /
    • pp.217-235
    • /
    • 2024
  • Concrete-filled steel tubes (CFSTs) nowadays are widely used as the main parts of momentous structures, and its connection has gained increasing attention as the complexity in configuration and load transfer mechanism. This paper proposes a novel CFST pier-to-footing incorporating tube-confined RC encasement. Such an innovative approach offers several benefits, including expedited on-site assembly, effective confinement, and collision resistance and corrosion resistance. The seismic behavior of such CFST pier-to-footing connection was studied by testing eight specimens under quasi-static cyclic lateral load. In the experimental research, the influences on the seismic behavior and the order of plastic hinge formation were discussed in detail by changing the footing height, axial compression ratio, number and length of anchored bars, and type of confining tube. All the specimens showed sufficient ductility and energy dissipation, without significant strength degradation. There is no obvious failure in the confined footing, while local buckling can be found in the critical section of the pier. It suggests that the footing provides satisfactory strength protection for the connection.

SCP 개량지만의 압밀거동에 대한 스미어 효과 (Smear Effect on Consolidation Behaviors of SCP-improved Ground)

  • Kim, Yun-Tae
    • 한국지반공학회논문집
    • /
    • 제20권2호
    • /
    • pp.59-66
    • /
    • 2004
  • SCP 개량지반은 연약지반에 타설된 모래말뚝과 주변 연약지반으로 구성된 복합지반을 형성한다. 복합지반에 상재하중이 작용할 경우, SCP쪽으로 반경방향의 흐름에 의하여 시간의존적인 압밀거동이 유발될 뿐만 아니라, SCP와 주변 연약지반 사이에서 강성도 차이로 인하여 응력전이가 유발된다. 본 논문은 SCP 개량지반의 압밀거동에 대한 교란효과의 영향을 고려하기 위하여 원통형 실린더 지반에 대한 수치해석을 수행하였다. 수치해석결과 연약지반의 교란영역은 유효응력-간극수압의 거동, 응력전이기구, 응력분담비에 영향을 줌을 알 수 있었다. 또한 SCP와 점토 사이의 응력전이량은 상부 z/H=0.25에서 가장 크며, 깊이가 증가함에 따라 감소한다. 응력분담비는 상수값이 아니라 압밀과정에 의존하며, 교란영역을 가진 연약지반의 응력분담비는 교란영역이 없는 연약지반의 응력분담비보다 큼을 알 수 있다.