• Title/Summary/Keyword: Load transfer method

Search Result 601, Processing Time 0.025 seconds

A Conduction Band Control AC-DC Buck Converter for a High Efficiency and High Power Density Adapter (고효율, 고전력밀도 아답터를 위한 도통밴드 제어 AC-DC 벅 컨버터)

  • Moon, SangCheol;Chung, Bonggeun;Koo, Gwanbon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.38-39
    • /
    • 2017
  • This paper proposes a new control method for an AC-DC Buck converter which is utilized as a front-end converter of a 2-stage high power density adapter. In the conventional adapter applications, 2-stage configuration shows higher power transfer efficiency and higher power density than those of the single stage flyback converter. In the 2-stage AC-DC converter, the boost converter is widely used as a front-end converter. However, an efficiency variation between high AC line and low AC line is large. On the other hand, the proposed conduction band control method for a buck front-end converter has an advantage of small efficiency variation. In the proposed control method, switching operation is determined by a band control voltage which represents output load condition, and an AC line voltage. If the output load increasesin low AC line, the switching operation range is expanded in half of line cycle. On the contrary, in light load and high line condition, the switching operation is narrowed. Thus, the proposed control method reduces switching loss under high AC line and light load condition. A 60W prototype which is configured the buck and LLC converter with the proposed control method is experimented on to verify the validity of the proposed system. The prototype shows 92.16% of AC-DC overall efficiency and 20.19 W/in 3 of power density.

  • PDF

Simulation of Motion Accuracy Considering Loads in Linear Motion Units (부하를 고려한 직선운동유니트의 정밀도 시뮬레이션 기술)

  • Khim, Gyungho;Park, Chun Hong;Oh, Jeong Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.5
    • /
    • pp.405-413
    • /
    • 2015
  • This paper presents the motion accuracy simulation considering loads such as workpiece weight, cutting force, cogging force of a linear motor, and force caused by misalignment and runout error of a ballscrew in linear motion units. The transfer function method is basically utilized to estimate 5-DOF motion errors, together with the equilibrium equations of force and moment on the table. The transfer function method is modified in order to consider clearance changed according to the loads in the double sided hydrostatic/aerostatic bearings. Then, the analytic model for predicting the 5-DOF motion errors is proposed with the modified transfer function method. Motion errors were simulated under different loading conditions in the linear motion units using hydrostatic, aerostatic, and linear motion bearings, respectively. And the proposed analytic model was verified by comparing the estimated and measured motion errors.

Experimental and theoretical studies on SHS column connection with external stiffening ring under static tension load

  • Rong, Bin;You, Guangchao;Zhang, Ruoyu;Ma, Xu;Quan, Xinxin
    • Steel and Composite Structures
    • /
    • v.28 no.2
    • /
    • pp.167-177
    • /
    • 2018
  • In order to investigate mechanical properties in the core area of Square Hollow Section(SHS) column connection with external stiffening ring, four specimens were tested under the static tension load. The failure modes, load-displacement curves and strain distribution were analyzed to study the mechanical properties and the load transfer mechanism of the core area of connections. The connections behave good ductility and load-bearing capacity under the static tension load. Parametric analysis was also conducted, in which the thickness of steel tube, extended width and thickness of the stiffening ring were considered as the parameters to investigate the effects on mechanical properties of the connections. Based on the experimental results, an analytical method for the bearing capacity of connection with external stiffening ring under the static tension load was proposed. The theoretical results and the experimental results are in good agreement, which indicates that the theoretical calculation method of the bearing capacity is advisable.

Analysis of Soil Resistance on Laterally Loaded Piles Considering Soil Continuity (지반의 연속성을 고려한 말뚝의 수평지반저항력 산정)

  • Kim, Young-Ho;Jeong, Sang-Seom
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.4C
    • /
    • pp.175-183
    • /
    • 2010
  • The load distribution and deflection of large diameter piles are investigated by lateral load transfer method (p-y curve). The emphasis is on the effect of the soil continuity in a laterally loaded pile using 3D finite element analysis. A framework for determining a p-y curve is calculated based on the surrounding soil stress. The parametric studies that take into account the soil continuity are also presented in this paper. Through comparisons with results of field load tests, it is found that the prediction by the present approach is in good agreement with the general trend observed by in situ measurements and thus, represents a significant improvement in the prediction of a laterally loaded pile behavior. Therefore, a present study considering the soil continuity would be more economical pile design.

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

A Study on Analysis of Core-Wall Structure Subjected to Torque (비틀림 하중(荷重)을 받는 심벽구조물(心壁構造物)의 해석(解析)에 관한 연구(研究))

  • Kim, Sung Chil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.137-144
    • /
    • 1983
  • Core walls for tall building is one of the structures to support lateral load. Since most structural elements used for resisting which ate relatively weak against torsion, it is important to investigate tosional effects in the analysis and design of tall buildings. Rutenberg proposed a more refined theory on the torsional analysis of core walls which can be used when the stiffness of lintel beams are small or large. In this paper a more refined method to analysis the torsion of core wall structures with variable cross sections and being subjected to arbitrarilly distributed load was suggested. To reduce complex and a great number of calculations and to enhance the generality and flexibility of application of this method, the discrete method using transfer matrix formulation was used. Then this method can be easily applied to irregular and variational sections, has no necessity to get particular solution for each of loading conditions, and the maximum size of matrix calculated is $4{\times}4$, which makes this approach more appropriate for design office calculations using comuters of any sizes or even desk calculators.

  • PDF

Implementation of Wireless Power Transfer Circuit by Using Magnetic Resonant Coupling Method

  • Lho, Young-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.306-309
    • /
    • 2019
  • Wireless charging is a technology of transmitting power through an air gap to an electrical load for the purpose of energy dissemination. Compared to traditional charging with code, wireless power charging has many benefits of avoiding the hassle from connecting cables, rendering the design and fabrication of much smaller devices without the attachment of batteries, providing flexibility for devices, and enhancing energy efficiency, etc. A transmitting coil and a receiving coil for inductive coupling or magnetic resonant coupling methods are available for the near field techniques, but are not for the far field one. In this paper, the wireless power transfer (WPT) circuit by using magnetic resonant coupling method with a resonant frequency of 13.45 Mhz for the low power system is implemented to measure the power transmission efficiency in terms of mutual distance and omnidirectional angles of receiver.

Load Transfer Behaviors of the Splice-Jointed Fiber Metal Laminates (연결이음 접합된 섬유금속적층판의 하중전달 거동 연구)

  • Roh Hee Seok;Choi Won Jong;Ha Min Su;Choi Heung Soap
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.2 s.233
    • /
    • pp.220-227
    • /
    • 2005
  • In this study, stress-displacement analytic solutions are obtained by a shear lag modeling method constructed for the spliced joint area with a splicing gap in the fiber metal laminate (FML). This gap can be empty or be filled with an adhesive material of elastic modulus $E_a$. Two splicing types are considered for spliced shear models, one for spliced in the center metal layer, the other for spliced in the outer metal layer. It is shown that from the viewpoint of the load transfer efficiency and the avoidability of disbond generation due to the shear and axial stresses at the interface between metal layer and composite layer of the gap-front in the spliced area, the center spliced type (k=2) is much preferable to the outer spliced type (k=1).

Analysis of Group Pile-Cap Interaction by Load Transfer Approach (하중전이법에 의한 말뚝-캡 상호작용 해석)

  • 정상섬;정상훈;원진오
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.3
    • /
    • pp.95-102
    • /
    • 2001
  • 본 연구에서는 말뚝-지반, 말뚝-캡 상호작용을 고려한 군말뚝 거동을 해석하는 효율적인 알고리즘을 제안하였다. 단독말뚝의 말뚝-지반 상호작용은 하중전이법을 사용하여 비선형적인 특성을 갖는 지반스프링(p-y, t-z, q-z 곡선등)을 이용하여 모델링하였으며 Beam-column 방법을 이용하여 말뚝-지반 시스템을 수치적으로 모델링하였다. 좀 더 실제적인 군말뚝의 해석을 위해서 지반-말뚝-지반 상호작용에 의한 그룹효과와 더불어 군말뚝 내에서 말뚝의 위치 및 말뚝과 말뚝캡의 결합조건에 따른 말뚝-캡 상호작용에 의한 효과를 고려하였다. 본 연구에서는 말뚝-캡의 상호작용에 중점을 두었으며 Beam-column 방법을 이용하여 이를 해석할 수 있는 타당한 수치해석적 방법을 개발하고자 하였다. 개발된 알고리즘을 수치해석 예제를 통해 비교, 검증하였다.

  • PDF

A Study on the Heat Load Transferred to a Passenger Vehicle (자동차 열부하의 계산)

  • 오상한;이창원;원성필
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.50-59
    • /
    • 1996
  • The computer simulation program that calculates the transient heat load transferred to a passenger vehicle has been developed. Method for modeling mathematically various kinds of the heat load was presented and the derived equations were solved numerically. To find out the accuracy of the simulation program, the correlation of experimental and analytical results was demonstrated. By using this program, the typical characteristics about temperature distribution and instantaneous or of vehicle body color, material of glass, air-conditioning capacity, driving direction, and speed. Under a steady-state condition, the ratios of the heat load, resulting form vehicle body, glass, and interior part, were 35%, 29%, and 36%, respectively.

  • PDF