• 제목/요약/키워드: Load transfer mechanism

검색결과 218건 처리시간 0.022초

CORIUM BEHAVIOR IN THE LOWER PLENUM OF THE REACTOR VESSEL UNDER IVR-ERVC CONDITION: TECHNICAL ISSUES

  • Park, Rae-Joon;Kang, Kyoung-Ho;Hong, Seong-Wan;Kim, Sang-Baik;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • 제44권3호
    • /
    • pp.237-248
    • /
    • 2012
  • Corium behavior in the lower plenum of the reactor vessel during a severe accident is very important, as this affects a failure mechanism of the lower head vessel and a thermal load to the outer reactor vessel under the IVR-ERVC (In-Vessel corium Retention through External Reactor Vessel Cooling) condition. This paper discusses the state of the art and technical issues on corium behavior in the lower plenum, such as initial corium pool formation characteristics and its transient behavior, natural convection heat transfer in various geometries, natural convection heat transfer with a phase change of melting and solidification, and corium interaction with a lower head vessel including penetrations of the ICI (In-Core Instrumentation) nozzle are discussed. It is recommended that more detailed analysis and experiments are necessary to solve the uncertainties of corium behavior in the lower plenum of the reactor vessel.

Sliding Wear Behavior of Plasma Sprayed Zirconia Coatingagainst Silicon Carbide Ceramic Ball

  • Le Thuong Hien;Chae Young-Hun;Kim Seock Sam;Kim Bupmin;Yoon Sang-bo
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.66-74
    • /
    • 2004
  • The sliding wear behavior of $ZrO_2-22wt\%MgO\;(MZ)\;and\;ZrO_2-8wt\%Y_2O_3\;(YZ)$ deposited on a casting aluminum alloy with bond layer (NiCrCoAlY) by plasma spray against an SiC ball was investigated under dry test conditions at room temperature. At all load conditions, the wear mechanisms of the MZ and the YZ coatings were almost the same. The wear mechanisms involved the forming of a smooth film by material transferred on the sliding surface and pullout. The wear rate of the MZ coating was less than that of the YZ coating. With an increase normal load the wear rate of the studied coatings increased. The SEM was used to examine the sliding surfaces and elucidate likely wear mechanisms. The EDX analysis of the worn surface indicated that material transfer was occurred from the SiC ball to the disk. It was suggested that the material transfer played an important role in the wear performance.

  • PDF

Experimental investigation of novel pre-tightened teeth connection technique for composite tube

  • Li, Fei;Zhao, Qilin;Chen, Haosen;Xu, Longxing
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.161-172
    • /
    • 2017
  • A new composite tube connection method called the pre-tightened teeth connection technique is proposed to improve the composite tube connection efficiency. This paper first introduces the manufacturing process of the proposed technique. It then outlines how the mechanical properties of this technology were tested using four test groups. The factors that influence the load-bearing capacity and damage model of the connection were analyzed, and finally, the transfer load mechanism was investigated. The following conclusions can be obtained from the research results. (1) The new technique improves the compressive connection efficiency by a maximum of 79%, with the efficiency exceeding that of adhesive connections of the same thickness. (2) Changing the depth of teeth results in two types of damage: local compressive damage and shear damage. The bearing capacity can be improved by increasing the depth, length, and number of teeth as well as the pre-tightening force. (3) The capacity of the technique to transfer high loads is a result of both the relatively high interlaminar shear strength of the pultruded composite and the interlaminar shear strength increase provided by the pre-tightening force. The proposed technique shows favorable mechanical properties, and therefore, it can be extensively applied in the engineering field.

$SiC_p/Al-Si$ 복합재료의 고온변형 특성 (High Temperature Deformation Behavior of $SiC_p/Al-Si$ Composites)

  • 전정식;고병철;김명호;유연철
    • 소성∙가공
    • /
    • 제3권4호
    • /
    • pp.427-439
    • /
    • 1994
  • The high temperature deformation behavior of $SiC_p/Al-Si$ composites and Al-Si matrix was studied by hot torsion test in a range of temperature from $270^{\circ}C$ to $520^{\circ}C$ and at strain rate range of $1.2{\times}10_{-3}~2.16{\times}10_{-1}/sec$. The hot restoration mechanisms for both matrix and composites were found to be dynamic recrystallization(DRX) from the investigation of flow curves and microstructural evolutions. The Si precipitates and SiC particles promoted DRX, and the peak strain$({\varepsilon}_p)$ of the composites was smaller than that of the matrix. Flow stresses of $SiC_p/Al-Si$ composites were found to be generally higher than the matrix, but the difference was quite small at higher temperature due to the decrease of capability of load transfer by SiC particles. With increasing temperature, failure strain of matrix and composites are inclined to increase, the increasing value of failure strain for the $SiC_p/Al-Si$ composites was small compared to that of matrix. The stress dependence of both materials on strain rate() and temperature(T) was examined by hyperbolic sine law, $\.{\varepsilon}=A_1[sinh({\alpha}{\cdot}{\sigma})]_n$exp(-Q/RT)

  • PDF

Behavior of a combined piled raft foundation in a multi-layered soil subjected to vertical loading

  • Bandyopadhyay, Srijit;Sengupta, Aniruddha;Parulekar, Y.M.
    • Geomechanics and Engineering
    • /
    • 제21권4호
    • /
    • pp.379-390
    • /
    • 2020
  • The behavior of a piled raft system in multi-layered soil subjected to vertical loading has been studied numerically using 3D finite element analysis. Initially, the 3D finite element model has been validated by analytically simulating the field experiments conducted on vertically loaded instrumented piled raft. Subsequently, a comprehensive parametric study has been conducted to assess the performance of a combined piled raft system in terms of optimum pile spacing and settlement of raft and piles, in multi-layered soil stratum subjected to vertical loading. It has been found that a combined pile raft system can significantly reduce the total settlement as well as the differential settlement of the raft in comparison to the raft alone. Two different arrangements below the piled raft with the same pile numbers show a significant amount of increase of load transfer of piled raft system, which is in line with the load transfer mechanism of a piled raft. A methodology for the factor of safety assessment of a combined pile raft foundation has been presented to improve the performance of piled raft based on its serviceability requirements. The findings of this study could be used as guidelines for achieving economical design for combined piled raft systems.

Experimental study on the hybrid shear connection using headed studs and steel plates

  • Baek, Jang-Woon;Yang, Hyeon-Keun;Park, Hong-Gun;Eom, Tae-Sung;Hwang, Hyeon-Jong
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.649-662
    • /
    • 2020
  • Although several types of rigid shear connectors have been developed particularly to increase load-carrying capacity, application is limited due to the complicated details of such connection. In this study, push-out tests were performed for specimens with hybrid shear connectors using headed studs and shear plates to identify the effects of each parameter on the structural performance of such shear connection. The test parameters included steel ratios of headed stud to shear plate, connection length, and embedded depth of shear plates. The peak strength and residual strength were estimated using various shear transfer mechanisms such as stud shear, concrete bearing, and shear friction. The hybrid shear connectors using shear plates and headed studs showed large load-carrying capacity and deformation capacity. The peak strength was predicted by the concrete bearing strength of the shear plates. The residual strength was sufficiently predicted by the stud shear strength of headed studs or by shear friction strength of dowel reinforcing bars. Further, the finite element analysis was performed to verify the shear transfer mechanism of the connection with hybrid shear connector.

강재 보강에 따른 기존 학교건축물의 내진성능에 관한 실험적 연구 (Experimental Study on Aseismic Performance Existing School Buildings due to the Steel Reinforcement)

  • 이호;박성무;권영욱;변상민
    • 한국공간구조학회논문집
    • /
    • 제13권3호
    • /
    • pp.45-55
    • /
    • 2013
  • The core aim of this paper is to empirically scrutinize a strength characteristic and ductility of the beam-column frame of reinforced with steel subjected to the cyclic lateral load. First and foremost, I the author embarks upon making four prototypes vis-$\grave{a}$-vis this research. Through this endeavour, the author has analysed cyclic behavior, fracture shape, ductility and energy dissipation of the normal beam-column frame and a beam-column frame of reinforced with steel. In addition, the survey has revealed the exact stress transfer path and the destructive mechanism in order to how much a beam-column frame of reinforced with steel has resistance to earthquake regarding all types of building, as well as school construction. To get the correct data, the author has compared the normal beam-column frame and three types of the beam-column frame of reinforced with steel following these works, the characteristic of cyclic behavior, destructive mechanism, ductility, and Energy dissipation of normal beam-column frame and a beam-column frame of reinforced with steel have been examined clearly.

부유식 해양플랜트 계류 체인의 면외굽힘 거동에 대한 연구 (A Study on Out-of-Plane Bending Mechanism of Mooring Chains for Floating Offshore Plants)

  • 임유창;김경수;정준모;강찬회
    • 대한조선학회논문집
    • /
    • 제47권4호
    • /
    • pp.580-588
    • /
    • 2010
  • OPB(out-of-plane bending)-induced failure of mooring chain was firstly addressed by CALM (catenary anchor leg mooring)-type offloading buoy, located approximately one mile away from the bow of the Girassol FPSO which was installed offshore area of Angola in September 2001. This study deals with verifying the load transfer mechanism between the first free chain link and connected two chain links inside the chain hawse. OPB moment to angle variation relationships are proposed by extensive parametric study where the used design variables are static friction coefficients, proof test loads, nominal tension forces, chain link diameters, chain link grades and chain link types. The stress ranges due to OPB moments are obtained using nonlinear FEAs (finite element analyses). Final stress ranges are derived considering ones from IPT (in-plane tension) forces. Also a formula for OPB fatigue assessment is briefly introduced.

Strain and crack development in continuous reinforced concrete slabs subjected to catenary action

  • Gouverneur, Dirk;Caspeele, Robby;Taerwe, Luc
    • Structural Engineering and Mechanics
    • /
    • 제53권1호
    • /
    • pp.173-188
    • /
    • 2015
  • Several structural calamities in the second half of the 20th century have shown that adequate collapse-resistance cannot be achieved by designing the individual elements of a structure without taking their interconnectivity into consideration. It has long been acknowledged that membrane behaviour of reinforced concrete structures can significantly increase the robustness of a structure and delay a complete collapse. An experimental large-scale test was conducted on a horizontally restrained, continuous reinforced concrete slab exposed to an artificial failure of the central support and subsequent loading until collapse of the specimen. Within this investigation the development of catenary action associated with the formation of large displacements was observed to increase the ultimate load capacity of the specimen significantly. The development of displacements, strains and horizontal forces within this investigation confirmed a load transfer process from an elastic bending mechanism to a tension controlled catenary mechanism. In this contribution a special focus is directed towards strain and crack development at critical sections. The results of this contribution are of particular importance when validating numerical models related to the development of catenary action in concrete slabs.

FBG센서가 내장된 스마트 텐던을 이용한 7연 강연선의 인발 하중전이 특성 (Load Transfer Characteristics of the 7-wire strand using FBG Sensor Embedded Smart Tendon)

  • 김영상;서동남;김재민;성현종
    • 한국방재학회 논문집
    • /
    • 제9권5호
    • /
    • pp.79-86
    • /
    • 2009
  • 최근 도심 구조물의 규모가 급격히 대형화됨에 따라 인접구조물이 존재하는 상태에서 대규모의 기초구조물의 설치를 위한 넓고 깊은 범위의 굴착이 빈번히 시행되고 있어 안전관리의 중요성이 크게 부각되고 있다. 시공 및 사용 중에 토류구조물의 안전성을 확보하기 위해서는 쏘일앵커, 쏘일네일 및 락앵커 등의 지반보강재에 작용하는 프리스트레스 하중(prestress force) 및 변형을 지속적이고 효과적으로 관측할 수 있는 방법이 필요하다. 그러나 현재 현장에서 주로 사용되는 전기저항식 로드셀과 스트레인게이지, 바이브레이팅 타입의 변형율계를 이용한 변형 및 장력의 측정은 센서 자체의 자기열화 특성 때문에 장기적인 모니터링에는 효과적이지 않을뿐더러 시험체 내부에서 다수의 측정점을 측정하기 위해서는 많은 스트레인게이지를 설치하기 위해 리드선의 공간이 크게 필요한 단점이 있다. FBG(Fiber Bragg Grating)센서는 스트레인게이지와 비교해서 매우 작은 직경을 가지며 전자기파에 의한 노이즈가 없고 내구성이 커서 장기적인 모니터링이 필요한 구조물에 매우 유용하게 사용될 수 있다. 본 연구에서는 7연 강연선의 센터 킹케이블에 FBG 센서를 내장한 스마트 텐던을 이용하여 토류구조물의 보강에 활용되고 있는 앵커와 주변 그라우트면의 하중전이 특성에 대한 일련의 실내실험 결과를 기술하였다. 연구결과 스마트 텐던은 기존의 스트레인 게이지 변형율계로는 마땅히 측정할 수 없던 7연 강연선과 그라우트면의 변형률을 매우 효과적으로 측정할 수 있을 뿐 아니라 하나의 선으로 여러 위치의 변형을 효과적으로 측정할 수 있어 지반보강재의 장력모니터링 뿐만 아니라 그라우트로 부착된 부분의 하중전이 특성을 효과적으로 파악할 수 있는 것으로 나타났다.