• 제목/요약/키워드: Load speed

검색결과 3,514건 처리시간 0.026초

지표층의 탄성계수 측정을 위한 새로운 탄성파 방법 (CHARACTERIZATION OF GEOTECHNICAL SITES BY MULTI-CHANNEL ANALSIS OF SURFACE WAVES(MCASW))

  • 박춘병
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1995년도 가을 학술발표회 논문집
    • /
    • pp.15.2-22
    • /
    • 1995
  • Evaluating stiffness of near-surface materials has been one of the critically important tasks in many civil engineering works. It is the main goal of geotechnical characterization. The so-called deflection-response method evaluates the stiffness by measuring stress-strain behavior of the materials caused by static or dynamic load. This method, however, evaluates the overall stiffness and the stiffness variation with depth cannot be obtained. Furthermore, evaluation of a large-area geotechnical site by this method can be time-consuming, expensive, and damaging to many surface points of the site. Wave-propagation method, on the other hand, measures seismic velocities at different depths and stiffness profile (stiffness change with depth) can be obtained from the measured velocity data. The stiffness profile is often expressed by shear-wave (S-wave) velocity change with depth because S-wave velocity is proportional to the shear modulus. that is a direct indicator of stiffiiess. The crosshole and downhole method measures the seismic velocity by placing sources and receivers (geophones) at different depths in a borehole. Requirement of borehole installation makes this method also time-consuming, expensive, and damaging to the sites. Spectral-Analysis-of-Surface-Waves (SASW) method places both source and receivers at the surface, and records horizontally-propagating surface waves. Based upon the theory of surfacewave dispersion, the seismic velocities at different depths are calculated by analyzing the recorded surface-wave data. This method can be nondestructive to the sites. However, because only two receivers are used, the method requires multiple measurements with different field setups and, therefore, the method often becomes time-consuming and labor-intensive. Furthermore. the inclusion of noise wavefields cannot be handled properly, and this may cause the results by this method inaccurate. When multi-channel recording method is employed during the measurement of surface-waves, there are several benefits. First, usually single measurement is enough because multiple number (twelve or more) of receivers are used. Second, noise inclusion can be detected by coherency checking on the multi-channel data and handled properly so that it does not decrease the accuracy of the result. Third, various kinds of multi-channel processing techniques can be applied to f1lter unwanted noise wavefields and also to analyze the surface-wavefields more accurately and efficiently. In this way, the accuracy of the result by the method can be significantly improved. Fourth, the entire system of source, receivers, and recording-processing device can be tied into one unit, and the unit can be pulled by a small vehicle, making the survey speed very fast. In all these senses, multi-channel recording of surface waves is best suited for a routine method for geotechnical characterization in most of civil engineering works.

  • PDF

법랑질에 의한 수종의 간접복합레진의 마모에 관한 연구 (AN IN-VITRO WEAR STUDY OF INDIRECT COMPOSITE RESINS AGAINST HUMAN ENAMEL)

  • 이현정;전영찬;정창모;정희찬
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.611-620
    • /
    • 2007
  • Statement of problem: Second-generation indirect composite resins have been improved flexural strength, compressive strength, hydrolytic degradation resistance, wear resistance compared to first-generation indirect composite resins, but there are still some problems as hydrolysis and low wear resistance. Some manufacturers claim that wear resistance of their materials has been improved, but little independent study has been published on wear properties of these materials and the properties specified in the advertising materials are largely derived from in-house or contracted testing. Purpose: This study was to evaluate the wear of indirect composite resins (SR Adore, Sinfony, Tescera ATL) and gold alloy against the human enamel. Material and method: Extracted human incisors and premolars were sectioned to $2{\times}2{\times}2mm$ cube and embedded in the clear resin and formed conical shaped antagonist to fit the jig of pin-on-disk tribometer. Total 20 antagonists were stored in distilled water. Five disk samples, 24mm in diameter and 1.5mm thick, were made for each of three groups of indirect composite resins and gold alloy group, and polished to #2,000 SiC paper on auto-polishing machine. Disk specimens were tested for wear against enamel antagonists. Wear test were conducted in distilled water using a pin-on-disk tribometer under condition (sliding speed 200rpm contact load 24N, sliding distance 160m). The wear of the enamel was determined by weighing the enamel antagonist before and after test, and the weight was converted to volumes by average density. The wear tracks were analyzed by scanning electron microscopy and surface profilometer to elucidate the wear mechanisms. Statistical analysis of the enamel wear volume, wear track depth and wear tract width of disk specimens were accomplished with one-way ANOVA and the means were compared for significant differences with Scheffe's test. Results: 1. The enamel wear was most in gold alloy, but there were no statistically significant differences among all the groups (P>.05). 2. In indirect composite resin groups, the group to make the most shallow depth of wear tract was Sinfony, followed by Tescera ATL, SR Adoro (P<.05). Gold alloy was shallower than Sinfony, but there was no statistically significant difference between Sinfony and gold alloy (P>.05). 3. The width of wear tract of SR Adore was larger than the other groups (P<.05), and there were no statistically significant differences among the other groups (P>.05). 4. SEM analysis revealed that Sinfony and gold alloy showed less wear scars after test, Tescera ATL showed more wear scars and SR Adore showed the most. Conclusion: Within the limits of this study, Sinfony and gold alloy showed the least wear rates and showed similar wear patterns.

복합가속열화시험을 통한 레일체결장치 폴리우레탄 탄성패드의 열화 경향 분석 (Evaluation of the Degradation Trend of the Polyurethane Resilient Pad in the Rail Fastening System by Multi-stress Accelerated Degradation Test)

  • 성덕룡;박광화
    • 한국철도학회논문집
    • /
    • 제16권6호
    • /
    • pp.466-472
    • /
    • 2013
  • 국내외적으로 도시철도 및 고속철도에서 콘크리트궤도 부설이 증가하고 있는 추세에 있다. 콘크리트궤도에서 필수적으로 사용되고 있는 레일체결장치의 탄성패드는 열차하중에 대한 충격을 완화시켜주는 중요한 역할을 담당하고 있다. 일반적으로 탄성패드의 강성변화를 평가하기 위해서는 단순피로시험[1]이 시행되고 있으나 이는 실제 철도환경조건과는 상이할 수 있다. 본 연구에서는 실제 철도현장에서 통과톤수를 받은 탄성패드에 대한 정적스프링계수를 측정하였다. 또한, 신품 탄성패드에 대해서 단순피로시험과 복합가속열화시험을 수행하였다. 사용한 탄성패드의 강성값은 사용시간과 반복횟수에 따른 시험결과값과 비교되었다. 시험결과의 비교를 통해 사용한 탄성패드의 정적스프링계수 변화경향이 반복하중과 열이 함께 고려된 복합가속열화시험결과와 동일한 경향을 보이는 것을 확인하였다. 또한, 복합가속열화와 관련된 T-NT식을 이용하여 탄성패드의 복합가속열화 모델을 도출하였으며, 약 2.62의 가속계수를 가지는 것을 확인하였다. 최종적으로 본 연구를 통해 폴리우레탄 탄성패드에 대한 복합가속열화 모델식을 제안하였다.

차륜-레일 상호작용력과 레일연마의 상관관계 분석 (Correlation Analysis between Dynamic Wheel-Rail Force and Rail Grinding)

  • 박준우;성덕룡;박용걸
    • 한국철도학회논문집
    • /
    • 제20권2호
    • /
    • pp.234-240
    • /
    • 2017
  • 레일표면 품질지수(QI: Quality Index)가 동적 궤도작용력에 미치는 영향을 알아보기 위하여 현장측정을 통해 레일연마횟수(Pass)에 따른 레일표면 품질지수의 변화를 분석하였다. 이론식에 근거하여 레일표면 품질지수에 영향을 미치는 매개변수인 열차속도에 따른 상관관계를 분석하였다. 레일연마횟수에 따른 레일표면 품질지수가 동적 궤도작용력에 미치는 영향을 분석한 결과, 레일표면 품질지수는 레일연마가 진행됨에 따라 감소하고 동적 궤도작용력 역시 일정 비율로 감소하는 것으로 분석되었으며, 고속주행 시 레일표면 품질지수에 따라 동적 궤도작용력은 크게 증가하는 것으로 분석되었다. 즉, 레일연마는 레일표면 품질지수를 일정비율로 감소시킬 수 있고, 궤도시스템 전반에 영향을 미치는 동적 궤도상호작용력을 저감 시킬 수 있는 것으로 분석되어 효율적인 레일표면관리를 위해서는 운행 노선의 열차속도를 감안한 레일표면 품질지수의 관리가 필요한 것으로 분석되었다.

Lithium Disilicate (IPS e.max CAD) 코어와 전장 도재 사이의 전단결합강도에 관한 연구 (A Study on the Shear Bond Strength of Veneering Ceramics to the Lithium Disilicate (IPS e.max CAD) Core)

  • 김기백;김재홍
    • 치위생과학회지
    • /
    • 제13권3호
    • /
    • pp.290-295
    • /
    • 2013
  • 본 연구는 심미 치과보철물에 사용되는 지르코니아, lithium disilicate 코어와 전장도재 사이의 전단결합강도를 측정하고, 금속도재관을 대조군으로 설정하여 비교하였다. 직사각기둥 모양의 시편을 각각 10개씩 제작하여 코어와 전장도재 사이의 전단결합강도를 측정한 후 파절면의 양상을 실체현미경을 통해 관찰하였다. 제한된 조건하에 시행된 실험을 통하여 심미보철 분야에 널리 적용되고 있는 치과용세라믹 코어의 전단결합강도를 확인하였으며, 측정 후 비교분석된 결과는 다음과 같다. 2종의 치과용 세라믹 코어와 전장도재 간에 전단결합강도는 금속도재관의 전단결합강도와 유의한 차이가 있었다 (p<0.05). 본 실험 결과를 토대로 ZB군은 임상적으로 받아들여지는 전단결합강도 범위 내 분포를 보이지만, LB군은 임상허용 범위에 못 미치는 결과값을 보였다. 금속도재관과 달리 지르코니아, lithium disilicate 전부도재관은 모두 혼합형 파절양상을 보였다. 결론적으로 전단결합강도 실험에 사용된 시편이 임상적인 치과보철물의 형태와는 달리 실험을 위한 시편의 형태로 제작되어 임상적 결과를 반영하지 못했으며 구강 내의 상황과도 다르다는 한계점을 가지고 있다. 추후에는 이를 보완하여 치과보철물과 유사한 형태의 시편을 이용한 전단결합 강도의 측정과 구강 내 조건을 고려한 추가 실험이 필요하다고 생각된다.

상아질 표면상태에 따른 광중합형 글래스아이오노머 시멘트의 전단결합강도에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH OF LIGHT CURED GLASS IONOMER CEMENTS TO CONTAMINATED DENTIN)

  • 김경화;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.609-621
    • /
    • 1997
  • The purpose of this study was to evaluate the shear bond strength of three light-cured glass ionomer cements to blood contaminated bovine dentin. The materials used in this study were Fuji II LC, Dyract and Variglass VLC. The dentin conditioners were 10% polyacrylic acid, 10% maleic acid and 10% phosphoric acid. 180 lower anterior bovine teeth were selected in this study. The teeth were embedded in acrylic resin and were grounded with 320 to 600 grit silicon carbide paper to create a flat dentin surface. The teeth were divided into SIX groups. The experimental procedures in six groups were as follows; Group l(GF) : Samples bonded to dentin surface with Fuji II LC after 10% polyacrylic acid treatment. Group 2(BGF) : Samples bonded to dentin surface with Fuji II LC after 10% polyacrylic acid treatment and blood contamination. Group 3(MD) : Samples bonded to dentin surface with Dyract after 10% maleic acid treatment. Group 4(BMD) : Samples bonded to dentin surface with Dyract after 10% maleic acid treatment and blood contamination. Group 5(PV) : Samples bonded to dentin surface with Variglass VLC after 10% phosphoric acid treatment. Group 6(BPV) : Samples bonded-to dentin surface with Variglass VLC after 10% phosphoric acid treatment and blood contamination. Group 1,3 and 5 were classified into the control groups, while group 2,4 and 6 were classified into the experimental groups. Each group contained 30 samples. After 24 hours water storage at $37^{\circ}C$, all smples were subjected to a shear load to fracture at a cross head speed of 1.0 mm/min with Instron universal testing machine(No. 4467). Debonded surfaces were observed under Scanning Electron Microscope(Hitachi S-2300) at 20kvp. The data were evaluated statistically at the 95% confidence level with Student's t-test. The following results obtained; 1. Shear bond strengths were higher in the control groups(1,3,5 group) than in the experimental groups(2,4,6 group). 2. The shear bond strength of group 5(PV) was the highest in the control groups, and the group 5 was significantly higher than the group l(GF) on the shear bond strength. 3. The group 4(BMD) was the highest on the shear bond strength, and the group 2(BGF) was the lowest in the experimental groups. The group 4(BMD) and 6(BPV) showed a significant difference with the group 2 on the shear bond strength. 4. All the groups showed an adhesive-cohesive failure. except the group 2(BGF) showing adhesive failure.

  • PDF

바이오매스 및 생분해 촉매제를 이용한 산화생분해 투명 바이오 필름 개발 (Development of Oxo-biodegradable Transparent Bio Films Using Biomass and Biodegradable Catalyst)

  • 유영선;김영태;박대성;최성욱
    • 청정기술
    • /
    • 제23권2호
    • /
    • pp.133-139
    • /
    • 2017
  • 식물로부터 유래하는 바이오매스를 25% 이상 함유하는 바이오 베이스 플라스틱은 탄소배출을 억제하는 효과가 있고, 한정된 자원인 석유의 소비량을 줄일 수 있으며, 산화생분해 첨가제를 추가 적용하면 폐기 후에는 미생물에 의해 생분해되기 때문에 친환경적인 소재로 최근 연구가 활발하다. 본 연구에서는 염화비닐수지에 식물체 유래 가소제, 생분해 촉매제를 첨가하여 생분해성 및 물성변화등을 관찰하였다. 또한 초기 신장율과 인장강도 등의 물성이 우수한 자연에서 분해되는 산화 생분해 투명 바이오 필름을 제조하여 식품포장재로서의 제품 안전성을 시험하였다. 염화비닐 수지와 1차 가소제, 2차 가소제, 방담제, 안정제를 비율에 맞게 투입한 다음, 고속혼합기에서 혼합한 후, 압출성형기를 이용하여 압출한 뒤 냉각 와인더 롤을 통해 두께 $12{\mu}m$의 대조구와 산화생분해 투명 바이오 필름을 제조하였다. 기계적 물성으로 인장강도, 연신율 및 최대하중연신율을 측정하였으며, 생분해 실험을 실시하였다. 식물체 유래 가소제, 생분해 촉매제로 제조된 투명 바이오 필름은 대조구 대비 인장강도 및 연신율이 큰 차이가 없는 것으로 나타났다. 또한 ASTM D 6954-04 방법에 따라 45일간 생분해 테스트를 한 결과 표준물질인 셀룰로오스 분말 대비 61.4%의 생분해를 나타내었다.

확장된 상부플랜지 PSC I형 거더교의 동특성 및 동적안정성 분석 (Dynamic Response of PSC I shape girder being used wide upper flange in Railway Bridge)

  • 박종권;장판기;차태권;김찬우;장일영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.125-135
    • /
    • 2015
  • 철도교량의 경제성 확보를 전제로 PSC I형 거더의 장경간화 추세는 근간에 가장 활발히 진행되고 있는 연구이며, 이에 따른 교량의 강성확보를 위한 거더의 효율적인 기하형상 선정은 우선시 되어야할 과제이다. 본 연구에서는 회전반경과 휨효율을 기반으로 확장된 상부플랜지의 거더 단면을 선정하였으며, 본 거더가 적용된 경간장 25m, 30m, 35m, 40m PSC I형 거더교를 대상으로 수치해석을 수행하여 국내 및 국외의 동적성능 기준과의 부합여부를 검증하였다. 또한 경간장 40m PSC I형 거더의 동적성능을 상대적으로 비교하기 위해서 현재 호남고속철도에서 적용된 40m PSC Box 거더교를 대상으로 동적 해석을 수행하였고 KTX열차와 화물열차 주행 시의 동적안정성을 수치해석적으로 검토하여 국내 및 국외의 동적 안정성 기준과 부합여부를 검토하였다. 추가로 표준열차하중과 충격계수를 고려하여 정적해석을 수행하고 한계치와의 부합여부를 분석하였다. 그 결과, 검토대상 PSC I형 거더 철도교는 모든 항목에서 국내 철도교량 관련 정적, 동적안정성 기준치를 만족하는 것으로 분석되었다.

체결장치 비선형 거동을 고려한 교량 단부에서의 체결장치 압상력 평가 (Evaluation of Uplift Forces Acting on Fastening Systems at the Bridge Deck End Considering Nonlinear Behaviors of the Fastening Systems)

  • 양신추;김학형;공정식
    • 한국철도학회논문집
    • /
    • 제20권4호
    • /
    • pp.521-528
    • /
    • 2017
  • 실제 체결장치는 들림하중이 작용할 때 압축하중이 작용할 때와 동일한 강성은 작은 하중범위 내에서 유지되고 어느 정도 들림하중이 커지면 매우 강한 비선형 거동특성을 보인다. 압상력 기준을 초과하는 개소들에서는 보통보다 매우 고가인 특수체결장치를 부설하여야하는데, 설계하고자하는 선로 전체구간에서 그 비용은 매우 크게 소요될 수 있다. 따라서 경제적 설계를 위하여 체결장치의 비선형 거동특성을 반영하여 압상력을 정확하게 평가할 필요가 있다. 본 연구에서는 현재 국내 콘크리트궤도에서 주로 사용되고 있는 일반 체결장치들(SFC와 System 300-1)을 대상으로 압상력 작용 시 거동특성을 파악하기 위하여 실내시험을 실시하였다. 시험결과를 토대로 수치해석에 적용하기 위한 체결장치의 비선형 하중-변위선도를 도출하였다. 기존의 선형모델과 더불어 도출된 비선형모델을 적용하여 교량단부의 변형에 따른 체결장치에 작용하는 압상력을 평가하였다. 또한 교량단부 체결장치 압상력에 미치는 영향요소인 침목간격, 교좌장치 중심으로부터 교량상판 최 끝단에 위치한 체결장치까지의 수평거리, 교량 거더높이 등에 대한 매개 변수연구를 통하여 이들 영향요소가 체결장치의 최대 압상력에 미치는 영향을 분석하였다. 평가결과 경제적인 궤도 설계를 위해서는 교량단부에 부설되는 체결장치의 사용성 검토 시에 체결장치의 비선형 특성이 반영될 필요가 있음을 알 수 있었다.

In vitro study of compressive fracture strength of Empress 2 crowns cemented with various luting agents

  • Kim Min-Ho;Yang Jae-Ho;Lee Sun-Hyung;Chung Hun-Young;Chang Ik-Tae
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.260-272
    • /
    • 2001
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic restorations because of their low strength. Their relatively lower strength and resistance to fracture have restricted the use of all-ceramic crowns to anterior applications where occlusal loads are lower. But there has been increasing interest in all-ceramic restorations because patients are primarily concerned with improved esthetics. Many efforts have been made to in prove the mechanical properties of dental ceramics. This study was designed to elucidate the influence of the luting agent on the strength of the Empress 2 crown (staining technique) cemented on human teeth. Seventy extracted human permanent molar teeth were chosen. Teeth were prepared for Empress 2 crowns with milling machine on a surveyor. A dental bur was placed in the mandrel that was positioned so that the long axis of the bur was perpendicular to the surveyor base. Dimensions of the Empress 2 crown preparation were $6^{\circ}$ taper on each side, $1.5{\pm}0.1mm$ shoulder margin, and 4mm crown height. The luting cements used in this study were as follow: 1. Uncemented 2. Zinc phosphate cements (Confi-Dental) 3. Conventional glass ionomer cement : Fuji 1 (GC) 4. Resin-modified glass ionomer cements : Fuji plus (GC) 5. Adhesive cements : Panavia F (Kuralay), Variolink II (Vivadent), Choice (Bisco). Fracture test using Instron. The crowns were loaded in compressive force to evaluate the effect of these cements on the breaking strength of these all-ceramic crowns. A steel ball with a diameter of 4mm was placed on the occlusal surface and load was applied to the steel ball by a cylindrical bolt with a crosshead speed of 0.5mm per minute until fracture occurred. The fractured surface was examined using Scanning Electron Microscopic Image (SEM) to discover the correlation between fracture strength and bonding capacity. Within the limitation of this in vitro study design, the results were as follows : 1. fomentations significantly increased the fracture resistance of Empress ceramic crowns compared to control. Uncemented (206.9 N): ZPC (812.9 N): Fuji 1 (879.5 N): Fuji Plus (937.7 N): Choice (1105.4 N): Variolink II (1221.1 N): Panavia F (1445.2 N). 2. Resin luting agent, treated by a silane bond enhancing agents, yielded a significant increase in fracture resistance. In some of the Panavia F group, a fracture extended into dentin. 3. According to SEM images of fractured Empress crowns, the stronger the bond at both interfaces(crown and die), the more fracture strength was acquired.

  • PDF