• 제목/요약/키워드: Load resistance

검색결과 2,429건 처리시간 0.026초

Systems to prevent the load resistance loss of pallet racks exposed to cyclic external force

  • Heo, Gwanghee;Kim, Chunggil;Baek, Eunrim;Jeon, Seunggon
    • Structural Engineering and Mechanics
    • /
    • 제83권6호
    • /
    • pp.745-756
    • /
    • 2022
  • This study aims to determine the cause of the load resistance loss in storage racks that can be attributed to external forces such as earthquakes and to improve safety by developing reinforcement systems that can prevent load resistance loss. To this end, a static cyclic loading test was performed on pallet racks commonly used in logistics warehouses. The test results indicated that a pallet rack exposed to an external force loses more than 50% of its load resistance owing to the damage caused to column-beam joints. Three reinforcement systems were developed for preventing load resistance loss in storage racks exposed to an external force and for performing differentiated target functions: column reinforcement device, seismic damper, and viscoelastic damper. Shake table testing was performed to evaluate the earthquake response and verify the performance of these reinforcement systems. The results confirmed that, the maximum displacement, which causes the loss of load resistance and the permanent deformation of racks under external force, is reduced using the developed reinforcement devices. Thus, the appropriate selection of the developed reinforcement devices by users can help secure the safety of the storage racks.

LRFD 설계를 위한 현장타설말뚝의 주면지지력 저항계수 산정 (Determination of Resistance Factors of Load and Resistance Factor Design for Drilled Shaft Based on Load Test)

  • 김석중;권오성;정성준;한진태;김명모
    • 한국지반공학회논문집
    • /
    • 제26권7호
    • /
    • pp.17-24
    • /
    • 2010
  • 기초구조물의 설계에 있어 전세계적으로 하중저항계수설계법(LRFD)이 확산되는 추세이다. 현재 국내의 현장타설 말뚝 설계에 있어 AASHTO(2007)에서 제안한 저항계수를 이용하고 있지만, 이는 미국 내 분포하는 무결암에 대한 저항계수이며 지역적 가변성이 큰 저항계수의 특성상 국내 암반에 적용하기에 부적합하다. 따라서 본 연구에서는 국내에서 수행된 재하시험 자료를 이용하여 국내 지반에 적합한 저항계수를 산정하였다. 측정지지력 확인이 가능한 8개 현장의 재하시험 결과 중 22개의 자료를 이용하여 4가지의 지지력 공식에 대한 저항편향계수를 산정하였으며, 이를 이용하여 신뢰성분석을 수행하였다. 그 결과 현장타설말뚝의 안전율이 3.0일 때 목표 신뢰도지수는 약 2.01~2.30 으로 산정되었다. 또한 최적화를 이용하여 저항계수 및 하중계수를 산정한 결과 저항계수는 약 0.48~0.56, 사하 중계수는 약 1.25, 활하중 계수는 약 1.75로 산정되었다. 하지만 목표 신뢰도지수를 AASHTO에서 제안한 3.0을 이용하여 저항계수를 산정하면 목표 신뢰도지수 2.0을 적용하였을 때 산정한 저항계수의 약 50% 값을 가진다.

Further study on level ice resistance and channel resistance for an icebreaking vessel

  • Hu, Jian;Zhou, Li
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권2호
    • /
    • pp.169-176
    • /
    • 2016
  • In this paper, further research is carried out to investigate the resistance encountered by an icebreaking vessel travelling through level ice and channel ice at low speed range. The present paper focuses on experimental and calculated ice resistances by some empirical formulas in both level ice and channel ice. In order to achieve the research, extra model tests have been done in an ice basin. Based on the measurements from model test, it is found that there exists a relationship between ice resistance, minimum ice load, maximum ice load and the standard deviation of ice load for head on operation in level ice. In addition, both level ice resistance and channel ice resistance are calculated and compared with model test results.

Oil-Jet 윤활시 가스터어빈용 고속 Ball Bearing 윤활특성 (Lubrication Characteristics of High-Speed Ball Bearing with Oil-Jet Lubrication)

  • 김기태
    • Tribology and Lubricants
    • /
    • 제12권4호
    • /
    • pp.28-34
    • /
    • 1996
  • The lubrication characteristics of high-speed ball bearings have been investigated empirically using 45mm bore split inner ring ball bearings employed in small industrial gas turbine engines with oil-jet lubrication method. For the close structural simulation, experiments carried out with bearing mounting supports of real engines, such as bearing housings and oil nozzle assemblies with squeeze film dampers. Thus the results of tests can be directly applied to the design and the development of gas turbine engines. Testing was done by varying operating speeds, axial load on bearings, and lubricant flow rates. During testing, the temperature of bearing at outer-ring face, the power consumption of the driving motor, and the rotating resistance of the bearing were measured. From this study, the representative factors for lubrication characteristics at high speed was found, and the most important one was not operating speed but axial load up to 1.95 million dmN speed and 2969 N axial load. Furthermore, the detailed variation of the rotational resistance of the bearing could be visualized by measuring the change of the radial load under the bearing supports. The rotational resistance consists of the frictional resistance and the bearing-cavity oil resistance.

Fire resistance of high strength concrete filled steel tubular columns under combined temperature and loading

  • Tang, Chao-Wei
    • Steel and Composite Structures
    • /
    • 제27권2호
    • /
    • pp.243-253
    • /
    • 2018
  • In recent years, concrete-filled box or tubular columns have been commonly used in high-rise buildings. However, a number of fire test results show that there are significant differences between high strength concrete (HSC) and normal strength concrete (NSC) after being subjected to high temperatures. Therefore, this paper presents an investigation on the fire resistance of HSC filled steel tubular columns (CFTCs) under combined temperature and loading. Two groups of full-size specimens were fabricated to consider the effect of type of concrete infilling (plain and reinforced) and the load level on the fire resistance of CFTCs. Prior to fire test, a constant compressive load (i.e., load level for fire design) was applied to the column specimens. Thermal load was then applied on the column specimens in form of ISO 834 standard fire curve in a large-scale laboratory furnace until the set experiment termination condition was reached. The results demonstrate that the higher the axial load level, the worse the fire resistance. Moreover, in the bar-reinforced concrete-filled steel tubular columns, the presence of rebars not only decreased the spread of cracks and the sudden loss of strength, but also contributed to the load-carrying capacity of the concrete core.

콘크리트 압축강도 및 하중비에 따른 CFT기둥의 내화성능에 관한 연구 (The Study on the Fire Resistance Performance of the CFT (Concrete filled Tube) Column According to the Concrete Compressive Strength and Load Ratio)

  • 조경숙;김흥열;김형준;권인규
    • 한국화재소방학회논문지
    • /
    • 제24권2호
    • /
    • pp.44-51
    • /
    • 2010
  • 본 연구의 목적은 성능적 내화설계를 기반으로 한 CFT 구조의 내화성능 설계기술 개발을 최종목표로 CFT 구조의 실증적 실험을 통한 내화성능을 도출하고 내부 콘크리트 압축강도와 하중비를 변수로 하여 수축량과 시험체 내부 온도를 측정하여 내화성능을 도출하여 성능설계를 위한 기초 자료로 활용하고자 하는데 있다. KS F 2257-1과 7의 기준에 따라 CFT 각형 기둥에 24MPa, 40MPa, 하중비 0.9, 0.6, 0.2를 재하하여 내화성능기준에 따른 결과 하중비 변화는 24MPa의 경우 하중비가 0.3 감소시 약 73분의 내화성능 향상효과가 있는 것으로 나타났다. 40MPa은 하중비 0.6, 0.2의 경우 내화성능시간은 31분, 180분으로 나타났다. 시험체 내부 콘크리트 강도 변화에 따른 내화성능평가 결과 강도가 증가할수록 내화성능은 감소하는 것으로 나타났다.

ANALYTICAL SIMULATION OF TRAVEL RESISTANCE OF THE RUBBER CRAWLER SYSTEM FOR FARM MACHINERY

  • Inaba, S.;Inoue, E.;Hashiguchi, K.;Matsuo, T.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.139-145
    • /
    • 2000
  • The mechanism of the inner resistance in a rubber crawler system has been investigated to reduce the power requirement (Kitano et al. 1994). The rolling resistance of the track roller, which is one of the major inner resistances, was measured for seven different vertical loads. The rolling resistance changed periodically and could be classified into three types. In case of the vertical load less than 500N, the rolling resistance was almost constant. For the vertical load greater than 500N, the maximum value of the rolling resistance increased. Further more in case of the vertical load greater than 1200N, negative resistance appeared. Analytical simulation of the travel resistance based on experimental results and static equilibrium equations derived from three-dimension mechanical model for the rubber crawler system. It was found that the simulation method was carried out to evaluate the travel resistance occurred by the rolling resistance of the track roller. The rolling resistance for each track roller arrangement and effects of the lug phase in the right and left rubber crawler could be estimated quantitatively.

  • PDF

풍화토지반 얕은기초에 대한 LRFD 저항계수 분석 (Analysis of LRFD Resistance Factor for Shallow Foundation on Weathered Soil Ground)

  • 김동건;김훈태;서지원;유남재
    • 한국지반환경공학회 논문집
    • /
    • 제16권6호
    • /
    • pp.5-11
    • /
    • 2015
  • 최근 구조물 기초 분야에 대한 한계상태설계법이 국제적인 기술표준으로 요구됨에 따라 연구기반이 미약한 얕은기초에 대한 하중저항계수설계법 개발의 필요성이 대두되었다. 본 연구에서는 얕은기초 설계 시 풍화토 지반에 위치한 얕은기초에 대한 하중저항계수설계법의 적용 방안에 대하여 연구를 수행하고 그에 따른 저항계수를 제안하였다. 얕은기초 국내 설계 및 시공자료를 수집하여 확률통계학적 기법에 의한 분석을 수행함으로써 풍화토지반 얕은기초의 불확실성과 저항편향계수를 정량적으로 분석하고, 신뢰성 해석 LEVEL II를 이용하여 목표신뢰도 지수를 평가하였으며, 산정된 신뢰도지수를 기존 문헌 값과 비교 분석하여 풍화토 지반 얕은기초에 대한 목표신뢰도 지수를 선정하였다. 국내 풍화토지반 얕은기초에 대한 하중계수를 적용하여 저항계수를 보정하였으며, AASHTO의 하중계수를 적용한 저항계수와 비교 분석하였다.

강관의 크기, 축력비 및 콘크리트 압축강도 변화에 따른 CFT 기둥부재의 내화성능에 관한 실험적 연구 (Experimental Study on Fire Resistance Performance of CFT (Concrete filled Tube) Column according to Cross Section of Steel, Concrete Compressive Strengths and Load Ratios)

  • 조경숙;김흥열;김형준;민병렬;권인규
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.104-111
    • /
    • 2010
  • CFT기둥은 강관내부에 콘크리트를 채워 넣은 구조로서, 화재 시 강관의 강도는 저하되나 내부 콘크리트의 높은 열용량 효과로 내화성능을 확보할 수 있는 구조이다. 본 연구에서는 강관내부의 충전된 콘크리트의 압축강도 및 축력비 변화에 따른 CFT기둥의 내화성능을 평가하였다. 내화성능의 평가는 KS F 2257-1 및 KS F 2257-7에 따라 수행되었으며, 적용 부재 단면은 $280{\times}280{\times}6$, 콘크리트 압축강도 24MPa, 40MPa 및 축력비 0.9, 0.6, 0.2를 실험변수로 설정하였다. 재하가열시험을 통한 내화성능평가 결과, 콘크리트 압축강도 24Mpa의 경우 축력비 0.9, 0.6, 0.2에서는 각각 27분, 113분, 3시간 이상으로 나타나 축력비 변화에 따른 내화성능이 크게 변화하는 것으로 나타났다. 콘크리트 압축강도 40MPa의 경우, 축력비 0.9, 0.6에서는 각각 19분, 28분으로 나타났다. 40MPa는 24MPa에 비해서 축력비 변화에 따른 내화성능 향상 효과는 크지 않은 것으로 나타났다. 이는 고강도의 경우 가열시 발생되는 내부 압력의 상승로 성능저하가 크게 발생되는 것으로 판단되었다.

잔류하중을 고려한 장대 PHC 말뚝의 양방향 재하시험 결과해석 (Analysis of a Bi-directional Load Test Result on tong PHC Piles in Consideration of Residual Load)

  • 김성렬;정성교;이봉열
    • 한국지반공학회논문집
    • /
    • 제24권6호
    • /
    • pp.85-93
    • /
    • 2008
  • 대심도 연약지반에 설치되는 말뚝은 말뚝의 길이가 길어져 지반지지력이 크므로 극한 지지력의 확인이 힘들고, 부마찰력에 의해 큰 잔류하중이 발생하기 때문에 하중전이시험을 수행하더라도 정확한 하중전이곡선을 산정하기 어렵다. 본 연구에서는 연약지반에 설치된 PHC 항타 말뚝을 대상으로 선단지지력과 주면마찰력을 분리측정할 수 있고 극한 지지력을 확인하기 용이한 하중전이 양방향 재하시험을 수행하였다. 말뚝설치 직후부터 말뚝변형률을 지속적으로 계측하여 잔류하중을 결정하였다. 잔류하중의 영향을 고려하여 참지지력과 참 하중-변위 곡선을 분석하였다. 이를 바탕으로 잔류하중이 포함된 주면마찰력에 대한 하중-변위 거동모형을 제안하였다. 결과적으로, 점토지반에 설치되는 장대말뚝의 재하실험 결과에 대한 정확한 분석을 위해서는 잔류하중을 고려하여야 한다는 것을 입증하였다.