• 제목/요약/키워드: Load resistance

검색결과 2,423건 처리시간 0.027초

석고보드 벽체의 시공높이에 따른 수평하중저항성 및 내충격성 변동 특성 (Variation Characteristics of Stiffness and Impact Resistance under Conastruction Height of Gypsum Board Wall)

  • 송정현;김기준;안홍진;신윤호;지석원;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.184-185
    • /
    • 2014
  • The purpose of this study is to experimentally evaluate the variation characteristics of stiffness and impact resistance under the construction height of gypsum board wall at the actual construction site. The method suggested in previous study was applied on the test method of horizontal load resistance and impact resistance. As a result of horizontal load resistance test, when the wall height is 2,400 mm, the maximum displacement is 13.6 mm and residual deformation is 0.5 mm, and when the wall height is 3,000 mm, the maximum displacement is 31.3 mm and the residual displacement is 6.8 mm. As a result of impact resistance test, the residual deformation of each specimen at 20 cm of fall height were 1.02 mm and 0.08 mm, respectively, the residual deformation at 40 cm of fall height were 1.58 mm and 0.35 mm, respectively, and the residual deformation at 60 cm of fall height were 2.23 mm and 2.48 mm, respectively.

  • PDF

탄소나노튜브 소재의 정밀 수동소자 적용을 위한 한계 정격전력 용량에 관한 연구 (A Study on the Limited Rate Power Capacity for Applications for Precision Passive Devices Based on Carbon Nanotube Materials)

  • 이선우
    • 한국전기전자재료학회논문지
    • /
    • 제35권3호
    • /
    • pp.269-274
    • /
    • 2022
  • We prepared carbon nanotube (CNT) paper by a vacuum filtration method for the use of a chip-typed resistor as a precision passive device with a constant resistance. Hybrid resistor composed of the CNT resistor with a negative temperature coefficient of resistance (T.C.R) and a metal alloy resistor with a positive T.C.R could lead to a constant resistance, because the resistance increase owing to the temperature increase at the metal alloy and decrease at the CNT could counterbalance each other. The constant resistance for the precision passive devices should be maintained even when a heat was generated by a current flow resulting in resistance change. Performance reliabilities of the CNT resistor for the precision passive device applications such as electrical load limit, environmental load limit, and life limit specified in IEC 60115-1 must be ensured. In this study, therefore, the rated power determination and T.C.R tests of the CNT paper were conducted. -900~-700 ppm/℃ of TCR, 0.1~0.2 A of the carrying current capacity, and 0.0625~0.125 W of the rated power limit were obtained from the CNT paper. Consequently, we confirmed that the application of CNT materials for the precision hybrid passive devices with a metal alloy could result in a better performance reliability with a zero tolerance.

일정 축력을 받는 콘크리트충전 원형 강관기둥의 내화성능 평가 (Fire Resistance of Concrete-Filled Circular Steel Tube Columns under Central Axial Loads)

  • 박수희;송경철;류재용;정경수;최성모
    • 한국강구조학회 논문집
    • /
    • 제20권5호
    • /
    • pp.655-663
    • /
    • 2008
  • 본 연구에서는 콘크리트충전 원형강관(원형 CFT)기둥의 내화성능을 평가하기 위하여 수치해석을 수행하였다. 강관은 SPSR 400 강재를 사용하였으며 강관 내에는 27.5MPa와 37.8MPa 강도의 콘크리트를 사용하였다. 콘크리트 강도, 작용 축력, 단면 직경을 변수로 설정하였다. 수치해석의 정확성을 검증하기 위하여, 기존의 각국 내화성능설계식들에 의한 계산 결과값과 비교 평가 하였다. 또한, 기존의 실대 원형 CFT기둥의 내화성능 평가 실험 결과와 함께 비교 분석하여 수치해석의 타당성을 검증하였다. 원형 CFT기둥의 내화실험 및 수치해석적 연구를 통해 도출된 내화저항시간과 축력비, 단면직경, 콘크리트 강도의 영향을 각형 CFT기둥의 내화성능과 비교 분석하여 각 영향인자들의 영향을 평가하였다. 본 연구의 수치해석적 연구는 실험결과와 비슷한 거동 및 내화성능을 보였다. 따라서 본 연구에서의 수치해석에 의한 CFT기둥의 내화 성능 예측은 타당하다고 판단된다.

일정 축력을 받는 콘크리트충전 각형 강관기둥의 내화성능 평가 (An Evaluation for the Fire Resistance of Concrete-Filled Steel Square Tube Columns under Constant Axial Loads)

  • 박수희;류재용;정경수;최성모
    • 한국강구조학회 논문집
    • /
    • 제19권6호
    • /
    • pp.703-714
    • /
    • 2007
  • 본 연구에서는 수치해석에 의해 일정 축력을 받는 콘크리트충전 각형강관(각형 CFT) 기둥의 내화성능을 평가하였다. 본 연구에 앞서 각형 CFT 기둥의 실대 내화성능평가 실험을 수행하였으며, 이로써 무내화피복 상태에서 CFT 기둥 자체만의 내화성능을 평가하였다. 강관은 SPSR 400 강재를 사용하였으며 강관 내에는 27.5MPa와 37.8MPa 강도의 콘크리트를 사용하였다. 콘크리트 강도, 작용 하중비와 기둥단면 직경을 변수로 설정하였다. 수치해석에 의해 예측된 내화성능의 타당성을 검증하기 위하여 실험결과값과 비교 평가해 본 결과, 해석값과 실험값이 서로 잘 일치하거나 해석값이 약간 저평가하고 있음을 확인하였다. 따라서 본 수치해석에 의한 CFT기둥 내화성능 예측은 타당하다고 판단된다. 내화성능 영향인자의 분석 결과, 축력비($N/N_c$)가 동일한 경우 콘크리트 강도가 적을수록 내화성능이 우수하며 단면직경이 클수록 내화성능은 향상되었다.

풍화암에 근입된 현장타설말뚝의 저항계수 산정 (Resistance Factors for Drilled Shafts Embedded in Weathered Rock)

  • 윤홍준;정성준;김명모
    • 한국지반공학회논문집
    • /
    • 제23권8호
    • /
    • pp.107-116
    • /
    • 2007
  • 하중저항계수설계법(LRFD)은 세계적으로 지반공학적 설계의 실무에서 사용이 증가하고 있으며 머지않아 현재의 허용응력설계법(ASD)을 완전히 대체할 것으로 예상된다. 하중저항계수설계법은 신뢰도해석(Reliability analysis)을 바탕으로 파괴확률을 정량화하여 상부구조물과 하부구조물을 일관된 신뢰도 수준으로 설계할 수 있게 하는 장점을 가지고 있다. 현재 암반에 근입된 현장타설말뚝의 저항계수는 단지 무결암 상태일 경우에 대하여 AASHTO에 의해 제시되어 있다. 그러나 국내의 경우, 말뚝이 근입되는 대부분의 기반암은 심하게 풍화되어 있다. 따라서 본 연구에서는 풍화암(흔히 IGM)에 대한 저항계수를 산정하고자 하였다. 이를 위해 국내 풍화암에 근입된 현장타설말뚝의 저항계수를 산정하기 위하여 신뢰도 해석을 수행하였다. 4개 현장에서 수행된 21본의 재하시험자료가 분석에 사용되었으며, 말뚝지지력을 계산하는 방법에 따라 저항계수는 $0.1{\sim}0.6$의 범위 내에서 산정되었다.

A simplified approach for fire-resistance design of steel-concrete composite beams

  • Li, Guo-Qiang;Wang, Wei-Yong
    • Steel and Composite Structures
    • /
    • 제14권3호
    • /
    • pp.295-312
    • /
    • 2013
  • In this paper, a simplified approach based on critical temperature for fire resistance design of steel-concrete composite beams is proposed. The method for determining the critical temperature and fire protection of the composite beams is developed on the basis of load-bearing limit state method employed in current Chinese Technical Code for Fire safety of Steel Structure in Buildings. Parameters affecting the critical temperature of the composite beams are analysed. The results show that at a definite load level, section shape of steel beams, material properties, effective width of concrete slab and concrete property model have little influence on the critical temperature of composite beams. However, the fire duration and depth of concrete slab have significant influence on the critical temperature. The critical temperatures for commonly used composite beams, at various depth of concrete and fire duration, are given to provide a reference for engineers. The validity of the practical approach for predicting the critical temperature of the composite beams is conducted by comparing the prediction of a composite beam with the results from some fire design codes and full scale fire resistance tests on the composite beam.

분리막을 이용한 정수처리공정에서 유, 무기물질이 막오염에 끼치는 영향 (Membrane Fouling Effect with Organic-Inorganic Materials Using the Membrane Separation in Drinking Water Treatment Process)

  • 이용택;오중교
    • 멤브레인
    • /
    • 제13권4호
    • /
    • pp.219-228
    • /
    • 2003
  • 분리막을 이용한 정수처리 공정의 최적화를 위하여 유기물 성분인 humic acid와 탁도를 유발하는 kaolin을 모사 용액으로 제조하여 막내 비저항 값을 최소화하면서 flux의 안정된 경향을 나타내는 최적의 운전 조건을 검토하여 보았다. 그 결과 압력이 증가함에 따라 낮은 비저항값에서 효율적인 분리막을 운전할 수 있으며 선속도가 증가함에 따라 높은 전단율에 의해 cake load는 줄어들었으며 이에따라 비저항값과 flux는 증가하는 경향을 나타내었다. 따라서 최적의 운전조건은 압력 $2.0 kg_f/cm^2,$ 선속도 0.92 m/sec으로 알 수 있었다.

장수명주택 벽배관 시스템의 양변기 하중저항성에 대한 실험적 연구 (An Experimental Study on the Load Resistance of Toilet Bowl in Long-Life Housing Infill System)

  • 이종호;서동구;김은영;황은경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.211-212
    • /
    • 2019
  • It is possible to realize the concept of long-life housing by utilizing the wall piping infill system. However, when using the wall piping infill system, there is no detailed standard in Korea. Problems may occur in actual use. In this study, we use the results obtained from the performance test method as a basic data. Since the load resistance test of the toilet is not available in Korea, GB 6952 (Sanitary wares) of China is applied. According to the experiment of load resistance of the toilet in this study, the strain recovery ability was good. However, it is not possible to exclude the possibility of permanent deformation of the toilet seat due to long - term repeated loading. Therefore, it is necessary to consider the stiffness enhancement of the wall (steel frame) to the fixing part when installing the toilet in the wall pipe infill system.

  • PDF

Studies on the effect of thermal shock on crack resistance of 20MnMoNi55 steel using compact tension specimens

  • Thamaraiselvi, K.;Vishnuvardhan, S.
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3112-3121
    • /
    • 2021
  • One of the major factors affecting the life span of a Reactor Pressure Vessel (RPV) is the Pressurised Thermal Shock (PTS). PTS is a thermo-mechanical load on the RPV wall due to steep temperature gradients and structural load created by internal pressure of the fluid within the RPV. Safe operating life of a nuclear power plant is ensured by carrying out fracture analysis of the RPV against thermal shock. Carrying out fracture tests on RPV/large scale components is not always feasible. Hence, studies on laboratory level specimens are necessary to validate and supplement the prototype results. This paper aims to study the fracture behaviour of standard Compact Tension [C(T)] specimens, made of RPV steel 20MnMoNi55, subjected to thermal shock through experimental and numerical investigations. Fracture tests have been carried out on the C(T) specimens subjected to thermal transient load and tensile load to quantify the effect of thermal shock. Crack resistance curves are obtained from the fracture tests as per ASTM E1820 and compared with those obtained numerically using XFEM and a good agreement was found. A quantitative study on the crack tip plastic zone, computed using cohesive segment approach, from the numerical analyses justified the experimental crack initiation toughness.

유공강판의 횡력저항능력에 대한 실험적 연구 (Experimental Study on the Characteristics of the Lateral Load Resistance of Perforated Steel Plates)

  • 박정아;이영욱
    • 대한건축학회논문집:구조계
    • /
    • 제36권5호
    • /
    • pp.137-146
    • /
    • 2020
  • In this study, an experimental research was performed to find the characteristics of the lateral load resistance of perforated steel plates which could be developed to retrofit existing RC framed buildings. The Specimens are tested with variables such as aspect ratio of plate, the ratio of perforation area, and the ratio of perforated diameter to strip which is more than 0.6. The lateral load was applied with displacement control until to reach 3.5% drift ratio. Through the experimental results, it was shown that the maximum strength of all specimens were reached at around 0.5% drift ratio and maintained until 3.5% drift ratio. From results, the modified strength prediction formula was derived with the variable ratio of the perforated diameter to strip. To evaluate seismic retrofit performance of RC frames using perforated steel plate, a simple design process was presented.