• 제목/요약/키워드: Load rejection

검색결과 113건 처리시간 0.026초

MVR모드에서 AVR모드로의 절환에 의한 여자계 모델정수 결정 (Identification of Excitation System Model Parameters from the Test of Switching from MVR Mode to AVR Mode)

  • 김동준;문영환;최경선;류승헌;송석하;이홍택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.91-94
    • /
    • 1996
  • A simulation procedure was developed for identifying Yungnam unit 2 excitation model parameters to improve the accuracy of stability simulation of KEPCO. First, generator model parameters are derived by using modified load rejection technique from measured load rejection test. For identifying excitation model parameters, switch was changed from MVR mode to AVR mode in Yungnam unit 2 excitation system instead of applying to a small step to the voltage reference($V_{ref}$) because of saving time and efforts, assuming the test result would show coincided result with applying to a small step to the $V_{ref}$. However, it was found that the response of switching from MVR to AVR is greatly different from it of applying small signal to the $V_{ref}$. A simulation procedure was needed to take into accounts of real AVR component status before and after switching from MVR to AVR. This paper reports the procedure which duplicated the measured response and addresses the merits of this test on conventional AVR step test.

  • PDF

이중 변환 UPS의 병렬 운전 시 외란 저감 성능 향상을 위한 정지 좌표계 상의 전향 보상 기법 (Feed-Forward Compensation Technique in Stationary Reference Frame for the Enhanced Disturbance Rejection Performance in Parallel Operation of Double-Conversion UPSs)

  • 류효준;윤영두;모재성;최승철;우태겸
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.367-375
    • /
    • 2022
  • Generally, a proportional-resonant controller is used to eliminate steady-state errors during the voltage-current control of a double-conversion uninterruptible power supply (UPS) in a stationary reference frame. Additionally, the feed-forward control compensating for the load current, which can be considered a disturbance of the voltage controller, can be used to improve the disturbance rejection performance. However, during the parallel operation of UPSs, circulating current can occur between UPS modules when performing both feed-forward control and droop control because feed-forward control reduces the circulating current impedance. This study proposes a feed-forward compensation technique that considers the impedance of circulating current. An additional feed-forward compensation technique is developed to enhance the disturbance rejection performance. The validity of the proposed feed-forward compensation technique is verified by the experiment results of the parallel operation of a 500 W double-conversion UPS module.

부하외란이 가해지는 전기.유압서보계의 속도 제어에 관한 연구 (A Study on the Speed Control of Electro - hydraulic Servo System under Load Disturbance)

  • 하석홍;권기수;이진걸
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권1호
    • /
    • pp.26-32
    • /
    • 1993
  • The loads exerted on electro-hydraulic servo system are classified into inertial, viscous, and spring load. The additional load called disturbances is also exerted on system but is generally not modeled. To deal with these kinds of loads, it is necessary to maintain the continuous signal transfer, so we can construct compensator to satisfy control specifications using feedback signal such as displacement, velocity, acceleration and pressure known as state variables. In case of controlling the speed of hydraulic motor, we must keep up robust performance for the various loads and disturbances acted on the system. However, the load flow rate in the valve is characterized by nonlinearity so that traditional theory of linear control could not be expected to give the desired performance. In this paper, it is shown that speed controller of hydraulic motor gives a good command following and disturbance rejection performance by applying sliding mode theory as a way of robust control to the nonlinearity, variation of loads and disturbances.

  • PDF

가변이득 PI 제어기를 이용한 BLDC 모터의 속도제어 (Speed Control of Permanent Magnet Brushless DC Motor using Variable Gain PI Controller)

  • 윤시영;이주
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1234-1239
    • /
    • 2013
  • This paper provides a technical review of speed control using variable gain PI algorithm for BLDC(Brushless DC) motor. Usually the PI control is used in many motor applications, but a general PI control has problems of overshooting and disturbance for response. By the change of PI gain in motor control operation, these problems can be solved. To find the optimized PI gains for BLDC motor control, many control methods have been proposed. In this paper, the control algorithm with a variable PI gain is applied to improve overshooting response in transient region and rapid load disturbance rejection. Fixed gain and variable gain PI controls are compared. The validity of the propose method is verified by experiment.

잡음 제거 회로를 이용한 LDO 레귤레이터 (Low Drop Out Regulator with Ripple Cancelation Circuit)

  • 김채원;권민주;정준모
    • 전기전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.264-267
    • /
    • 2017
  • 본 논문에서는 잡음 제거 회로를 이용하여 공급 전원 제거 비를 향상시킨 LDO(Low drop-out) 레귤레이터를 제안하였다. LDO 레귤레이터 내부의 오차증폭기와 패스 트랜지스터 사이에 잡음 제거 회로를 두어 전압 라인에서 들어오는 노이즈에 패스 트랜지스터가 받는 영향을 줄일 수 있게 설계하였으며, 기존의 LDO 레귤레이터와 동일한 레귤레이션 특성을 갖도록 했다. 제안한 회로는 0.18um 공정을 사용하였고 Cadence의 Virtuoso, Spectre 시뮬레이터를 사용하였다.

인공신경회로망에 기초한 직류모터제어에 관한 연구 (A Study on DC Motor Control based on Artificial Neural Networks)

  • 박진현;김영규
    • 전자공학회논문지B
    • /
    • 제31B권10호
    • /
    • pp.44-52
    • /
    • 1994
  • In this paper, we assume that the dynamics of DC motor and nonlinear load are unknown. We propose an inverse dynamic model of DC motor and nonlinear load using the artificial neural network and construck speed control system based on the proposed dynamic model. We also propose another dynamic model with speed prediction scheme using the artificial neural network that removes the undesirable time delay effect caused by the computation time during the real-time control. We suggest a dynamic model which has arbitrary number of speed arguments and is especially effective when the motor and load has large moment of inertia. Next, we suggest a controller that combine the neurocontrol and PID control with constant gain. We show that the proposed neurocontrol systems have capabilities of noise rejection and generalization to have good velocity tracking through computer simulations and experiments.

  • PDF

자동차용 가솔린 기관의 실린더 블록에 대한 열적 거동 해석 (Thermal Behavior Analysis on the Cylinder Block of an Automotive Gasoline Engine)

  • 손병진;김창헌
    • 한국자동차공학회논문집
    • /
    • 제6권5호
    • /
    • pp.211-221
    • /
    • 1998
  • Thermal behavior on the cylinder block of a 4-cylinder, 4-stroke 2.0L SOHC gasoline engine was numerically and experimentally analyzed. The numerical calculation was performed using the finite element method. The cylinder block was modelled as a three dimensional finite element by considering its geometry. The physical domain was devided into hexahedron elements. 16 thermocouples were installed at points of 2mm inside from cylinder wall near top ring of piston in cylinder block, which points have suffered major thermal loads and suggested as proper measurement points for engine design by industrial engineers. Under full load and 9$0^{\circ}C$ coolant temperature condition, temperature behavior of cylinder block according to engine speed were analyzed. The results showed that temperature rose gradually to conform to a function of 2nd~4th order of engine speed at intake side, exhaust and siamese side, respectively. As engine load was changed from 100 to 50% by 25% step, temperature curve also conformed to 2nd~7th order function of engine speed. Temperature differences by load condition were similar among 100, 75% and 50%. Under full load and coolant temperature of 11$0^{\circ}C$, temperature behavior were also analyzed and the result also showed conformance to 2n d~7th order function of engine speed. Temperature curve was transferred in parallel upwards corresponding coolant temperature rise.

  • PDF

Parallel Operation of Microgrid Inverters Based on Adaptive Sliding-Mode and Wireless Load-Sharing Controls

  • Zhang, Qinjin;Liu, Yancheng;Wang, Chuan;Wang, Ning
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.741-752
    • /
    • 2015
  • This study proposes a new solution for the parallel operation of microgrid inverters in terms of circuit topology and control structure. A combined three-phase four-wire inverter composed of three single-phase full-bridge circuits is adopted. Moreover, the control structure is based on adaptive three-order sliding-mode control and wireless load-sharing control. The significant contributions are as follows. 1) Adaptive sliding-mode control performance in inner voltage loop can effectively reject both voltage and load disturbances. 2) Virtual resistive-output-impedance loop is applied in intermediate loop to achieve excellent power-sharing accuracy, and load power can be shared proportionally to the power rating of the inverter when loads are unbalanced or nonlinear. 3) Transient droop terms are added to the conventional power outer loop to improve dynamic response and disturbance rejection performance. Finally, theoretical analysis and test results are presented to validate the effectiveness of the proposed control scheme.

부하추종 냉각수 시스템의 온도 제어를 위한 유전알고리즘 기반 비선형 PID 제어기 설계 (Genetic algorithm-based design of a nonlinear PID controller for the temperature control of load-following coolant systems)

  • 이유수;황순규;안종갑
    • 수산해양기술연구
    • /
    • 제58권4호
    • /
    • pp.359-366
    • /
    • 2022
  • In this study, the load fluctuation of the main engine is considered to be a disturbance for the jacket coolant temperature control system of the low-speed two-stroke main diesel engine on the ships. A nonlinear PID temperature control system with satisfactory disturbance rejection performance was designed by rapidly transmitting the load change value to the controller for following the reference set value. The feed-forwarded load fluctuation is considered the set points of the dual loop control system to be changed. Real-coded genetic algorithms were used as an optimization tool to tune the gains for the nonlinear PID controller. ITAE was used as an evaluation function for optimization. For the evaluation function, the engine jacket coolant outlet temperature was considered. As a result of simulating the proposed cascade nonlinear PID control system, it was confirmed that the disturbance caused by the load fluctuation was eliminated with satisfactory performance and that the changed set value was followed.