The Effect on Fouling Reduction by the Ball Cleaning System in a Compressed Type Refrigerator

  • Lee, Yoon-Pyo;Karng, Sarng-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.88-96
    • /
    • 2002
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

The Effect on Fouling Reduction by the Cleaning System in Compressed Type Refrigerator (압축식 냉동기에서 세정장치에 의한 파울링 억제효과)

  • 이윤표;강상우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.482-489
    • /
    • 2001
  • The present study was conducted to estimate the effect on fouling reduction in tubes of the condenser. It shows in detail how to calculate the fouling factor from the experimental results of refrigeration systems with or without the automatic cleaning system using sponge balls and to predict the variation of the factor with time. It also represents how to calculate the temperature and pressure decrease of the refrigerant vapor in the condenser and the load decrease of the compressor in the refrigeration system by fouling reduction.

  • PDF

Using Voltage Control Active Power Filter, Power Factor Improvement and Harmonics Reduction for Nonlinear Load (전압제어형 능동전력필터를 이용한 비선형부하의 고조파저감 및 역류개선)

  • 김병진;문학룡;송양희;임병국;전희종
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.403-408
    • /
    • 2000
  • In this paper, voltage control APF(Active Power Filter) is introduced to improve power factor and reduce harmonics generated from nonlinear load. The voltage controlled APF which is consisted of inverter and passive filter operates with nonlinear load simultaneously. Real power supplies from main power to load and reactive power provides from APF to load. According to the results o experiment and simulation, it is proved that the proposed system has the performance of improving power factor and reducing harmonics.

  • PDF

Application of Conservation Voltage Reduction using Automatic Voltage Regulator of Linear Voltage Control in Campus Microgrid with Power Consumption Reduction (에너지 절감을 고려한 캠퍼스 마이크로그리드에서 선형 전압제어 방식의 AVR을 이용한 CVR의 적용)

  • Lim, Il-Hyung;Lee, Myung-Hwan;Shin, Yong-Hark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1039-1046
    • /
    • 2017
  • Campus microgrid is designed and built by considering not only power generation but also power consumption management as connected microgrid type because the main goal of the campus microgrid is to save power consumption costs. There are many functions to achieve the goal and they are mainly to use generation-based functions such as islanding operation for peak management and for emergency events. In power distribution operation, Conservation Voltage Reduction (CVR) is applied in order to reduce power consumption. The CVR is defined as a function for load consumption reduction by voltage reduction in order to reduce peak demands and energy consumption. However, application of CVR to microgrid is difficult because the microgrid cannot control a tap of transformer in a substation and the microgrid normally is not designed with phase modifying equipment like a step-voltage-regulator which can control voltage in power distribution system operation. In addition, an impact of the CVR is depended on load characteristics such as a normal load, a rated power, and synchronous motors. Therefore, this paper proposes an application of CVR using linear voltage control based AVR in campus microgrid with power consumption reduction considering characteristics of load and component in the microgrid. The proposed system can be applied to each buildings by a configuration of power distribution cables; and the application results and CVR factor are presented in this paper.

Optimal Voltage and Reactive Power Scheduling for Saving Electric Charges using Dynamic Programming with a Heuristic Search Approach

  • Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.329-337
    • /
    • 2016
  • With the increasing deployment of distributed generators in the distribution system, a very large search space is required when dynamic programming (DP) is applied for the optimized dispatch schedules of voltage and reactive power controllers such as on-load tap changers, distributed generators, and shunt capacitors. This study proposes a new optimal voltage and reactive power scheduling method based on dynamic programming with a heuristic searching space reduction approach to reduce the computational burden. This algorithm is designed to determine optimum dispatch schedules based on power system day-ahead scheduling, with new control objectives that consider the reduction of active power losses and maintain the receiving power factor. In this work, to reduce the computational burden, an advanced voltage sensitivity index (AVSI) is adopted to reduce the number of load-flow calculations by estimating bus voltages. Moreover, the accumulated switching operation number up to the current stage is applied prior to the load-flow calculation module. The computational burden can be greatly reduced by using dynamic programming. Case studies were conducted using the IEEE 30-bus test systems and the simulation results indicate that the proposed method is more effective in terms of saving electric charges and improving the voltage profile than loss minimization.

Axial load-strain relationships of partially encased composite columns with H-shaped steel sections

  • Bangprasit, Papan;Anuntasena, Worakarn;Lenwari, Akhrawat
    • Steel and Composite Structures
    • /
    • v.45 no.1
    • /
    • pp.51-66
    • /
    • 2022
  • This paper presents the axial compression behavior of partially encased composite (PEC) columns using H-shaped structural steel. In the experimental program, a total of eight PEC columns with H-shaped steel sections of different flange and web slenderness ratios were tested to investigate the interactive mechanism between steel and concrete. The test results showed that the PEC columns could sustain the load well beyond the peak load provided that the flange slenderness ratio was not greater than five. In addition, the previous analytical model was extended to predict the axial load-strain relationships of the PEC columns with H-shaped steel sections. A good agreement between the predicted load-strain relationships and test data was observed. Using the analytical model, the effects of compressive strength of concrete (21 to 69 MPa), yield strength of steel (245 to 525 MPa), slenderness ratio of flange (4 to 10), and slenderness ratio of web (10 to 25) on the interactive mechanism (Kh = confinement factor for highly confined concrete and Kw = reduction factor for steel web) and ductility index (DI = ratio between strain at peak load and strain at proportional load) were assessed. The numerical results showed that the slenderness of steel flange and yield strength of steel significantly influenced the compression behavior of the PEC columns.

Solution for the Improvement in Structural Design & Application of PEB System for the Standard Livestock Housing(2008) (표준축사 모델에서 PEB시스템의 적용 및 구조설계 개선방안)

  • Park, Man-Woo;Do, Byung-Ho;Song, Jun-Ik
    • Journal of Animal Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.17-28
    • /
    • 2009
  • PEB system is more economical when compared with structures commonly used Hot rolled and welded light H-beam was introduced in the Standard Livestock Housing. This study suggested more economical technology for structural design by the reduction of live load, relief of deflection limit and reduction of importance factor. And, when applying wind Load as a result of examination with Low Rise Building Systems Manual considering open model, we can know that when the wind load is big, enclosed model is more stable than open model. In short, Suggesting more economical model and providing the method to reduce natural disaster, by the application of PEB system and the development of technology for structural design, are considered to strengthen the competitive power of farmhouse.

  • PDF

Estimation of the First Modal Participation Factor of a Shear Building under Earthquake Load (지진하중을 받는 전단구조물의 1차 모드참여계수 산정)

  • Hwang, Jae-Seung;Kim, Hong-Jin;Kang, Kyung-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.1 s.41
    • /
    • pp.25-32
    • /
    • 2005
  • Seismic load is distributed to modes of a structure through the modal participation factor(MPF). The modal participation factor is essential to analyze structural response under earthquake load. MPF of a real structure differs from that of analytical mathematical model due to the error induced from analytical assumptions and during the construction. In this study, an identification method is proposed to calculate the 1st MPF of real structure based on $H^{\infty}$ optimal model reduction. The MPF is obtained from the relationship between observability and controllability matrices realized from system identification and those of a prototype 2-degree state space model. The proposed method is verified thorough numerical examples.

Comparison of loads in Turkish earthquake code with those computed statistically

  • Firat, Fatih K.;Yucemen, M. Semih
    • Earthquakes and Structures
    • /
    • v.8 no.5
    • /
    • pp.977-994
    • /
    • 2015
  • In this study, earthquake loads are investigated statistically and compared with the nominal earthquake loads calculated according to the Turkish Earthquake Code, namely: "Specifications for Structures to be Built in Earthquake Areas". For this purpose, the "actual" mean load values estimated from statistical methods and the nominal load values computed according the Seismic Code are compared, with respect to some variations in the basic parameters, such as the importance factor, building height, site coefficient, seismic zone and seismic load reduction factor. In addition to the data compiled from different regions of Turkey, the published data and information in the foreign literature are also used in the determination of the earthquake load statistics. Although the dead and live loads acting on a structure are independent of the geographical location of the structure, environmental loads, such as earthquake loads are highly dependent on the location of the structure. Accordingly, for the assessment of statistical parameters associated with earthquake loads, twelve different locations which can represent the different seismic zones of Turkey as accurately as possible are chosen. As a result of the code calibration procedure considered in this study, it is observed that the load values obtained from the Turkish Seismic Code may overestimate or underestimate the actual seismic loads in some of the seismic zones.

Optimal Generation Expansion Planning with Load Management Effect (부하관리 효과를 고려한 최적 전원개발계획 수립에 관한 연구)

  • Park, Jong-Jin;Chung, Do-Young;Kim, Joon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.96-99
    • /
    • 1990
  • Recently, electric energy consumption pattern shows very high peak load with low load factor. This Load pattern have made electric utilities be interested in Load Management, many studies are reported. But most of these studies are concerned with Rate - Load shape relation, a few of these are concerned with generating cost reduction. In this study, the effect of Load Management is incorporated to establish optimal Generation Expansion Planning. Using avoided cost, optimal generation expansion planning is achieved to make maximum avoided cost of Electric utility. Dynamic programming technique is used to solve this algorithm.

  • PDF