• Title/Summary/Keyword: Load power factor

Search Result 847, Processing Time 0.034 seconds

Simulation Analysis on Static Safety of 55Hp-Servo-Based Hydrostatic Transmission (시뮬레이션 기반의 55마력급 서보식 정유압 무단변속기 정적구조안정성 분석)

  • Won, Jonggeun;Yoon, Jongil;Lee, Hyunah;Chung, Seonggyo;Jeong, Jaesu
    • Journal of Drive and Control
    • /
    • v.19 no.1
    • /
    • pp.34-42
    • /
    • 2022
  • Hydrostatic transmission (HST) comprises rotary parts, shafts, valve plate, swashplate, and servo pistons. Ensuring structural stability of each part of an HST has a significant impact on product safety. In this study, the structural stability of HST in agricultural machinery and industrial vehicles was analyzed using ANSYS software. For conservative evaluation, high-pressure conditions (35.5 MPa and 2 MPa pilot pressure) were applied as load conditions. The number of grids used in the calculations ranged from 0.4 to 0.8 million depending on modeling requirements. Structural analysis was performed for essential parts and safety factor was analyzed. All major parts of HST had a safety factor of ≥ 1.5. Thus, they were judged to be structurally safe. This study provides important information for designing an HST system.

Structural Safety Evaluation of Stabbing System for Pre-Piling Jacket Substructure under Construction (프리파일링 자켓 하부구조물용 스태빙시스템의 시공중 구조안전성 평가)

  • Youngcheol Oh;Jaeyong Ryoo;Daeyong Lee
    • Journal of Wind Energy
    • /
    • v.13 no.3
    • /
    • pp.79-87
    • /
    • 2022
  • A stabbing system is an underwater jointing structure for positioning the jacket substructure for offshore wind power on top of a pile foundation that is already installed in the seabed. In this paper, the structural safety of the stabbing system currently being developed in South Korea was evaluated through finite element analysis. For this study, conformity of the finite element modeling technique for a gripper (hydraulic cylinder) was reviewed, and the structural safety of the stabbing system was evaluated based on the stress safety factor under three design load combinations (combinations of vertical, shear, and moment loads). From the analysis, it was verified that the pile foundation and the stabbing system mounted on top of it are structurally safe according to the stress safety factor, and there will be no interference between major structural components (i.e., guide cone and pile foundation) due to rotation of the guide cone at the end of the jacket leg.

Effects of PTO gear face width on safety factors

  • Jang, Jeong-Hoon;Chung, Sun-Ok;Choi, Chang-Hyun;Park, Young-Jun;Chun, Won-Ki;Kim, Seon-Il;Kwon, Oh-Won;Kim, Chang-Won;Hong, Soon-Jung;Kim, Yong-Joo
    • Korean Journal of Agricultural Science
    • /
    • v.43 no.4
    • /
    • pp.650-655
    • /
    • 2016
  • Gears are components of transmission which transmit the power of an engine to a machine and offer numerous speed ratios, a compact structure, and high efficiency of power transmission. Gear train design in the automotive industry uses simulation software. However, PTO (Power Take-Off) gear design for agricultural applications uses the empirical method because of the wide range of load fluctuations in agricultural fields. The PTO is an important part of agricultural tractors which transmits the power to various tractor implements. Therefore, a simulation was essential to the optimal design of the PTO. When the PTO gear is optimally designed, there are many advantages such as low cost, reduced size, and light weight. In this study, we conducted the bending and contact safety factor simulation for the PTO gear of an agricultural tractor. The bending and contact safety factors were calculated on ISO 6336 : 2006 by decreasing the face widths of the PTO pinion and wheel gear from 18 mm at an interval of 1 mm. The safety factor of the PTO gear decreased as the face width decreased. The contact safety factors of the pinion and wheel gear were 1.45 and 1.53, respectively, when the face width was 18 mm. The simulation results showed that the face width of the PTO gear should be greater than 9 mm to maintain the bending and contact safety factors higher than 1. It would be possible to reduce the weight of the PTO gear for different uses and working conditions. This study suggests that the possibility of designing an optimal PTO gear decreases as its face width decreases.

Finite Element Analysis of Underground Electrical Power Cable Structures Considering the Effects of Construction Sequence (시공단계별 영향을 고려한 터널 전력구의 유한요소해석)

  • Kim, Sun-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.2
    • /
    • pp.147-155
    • /
    • 2013
  • In this paper structural analysis of underground electrical power cable structures which is excavated below the surface of the earth in the downtown area is carried out considering the effect of construction sequence. There are many various life-line facilities below the surface of the earth in the downtown area. MPDAP was used for finite element analysis of underground electrical power cable structures. Three typical sections are simulated by finite element models. Unbalanced equilibrium problems may be occurred when conventional finite element procedures were used for simulation of tunnel excavation. Therefore equilibrium perturbation concept was applied to solve these problems. The effects of time-dependent deformations in advancing tunnel excavation are considered in the stages of construction sequences as using the load distribution factor. It is shown that values of maximum displacement of both soil and rock surrounding underground electrical power cable structures obtained by our numerical studies are less than allowable values.

A Inverter Control System for Vertical Circulation Parking Facility (수직순환식 입체주차설비용 인버터 제어시스템)

  • Choi, Chul;Lee, Jin-Ha;Kim, Chul-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.294-302
    • /
    • 2004
  • In this study, we developed the inverter system to control Induction motor for the vertically circulation parking facility. In the case of calling a pallet, a car parking space, we basically stoned conventional system's problems, pallet is uncontrollable to the fixed position and braking system was worn by forcer braking with remaining speed. Also, by appling to converter controller, added to power regenerative control function, we confirmed the reduce of power supply capacity and the energy saving effect according to increasing operation frequency. The validity of this system is verified by 55kw induction motor driving system. Via this study, the proposed system shows the efficient use of parking facility and good operation characteristics by implementing position and speed control effectively on condition of load and shows energy saying effect by power factor control for the vertically circulation parking facility operation.

Conservativeness Evaluation of Response Acceleration Method used in Seismic Response Analysis of Power Cable Tunnel (전력구의 지진응답해석에 사용되는 응답진도법의 보수성 평가)

  • Lim, Jae-Sung;Kim, Gi-Bae;Chun, Nak-Hyun;Kim, Jae-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.34 no.5
    • /
    • pp.309-317
    • /
    • 2021
  • In this paper, we present the evaluation results for the conservatism of the response acceleration method (RAM), for seismic response analysis of box-type power cable tunnels. We studied 50 examples, considering the cross sections of 25 power cable tunnels, and two soil conditions for each power cable tunnel. A refined dynamic analysis method considering the soil-structure interaction was further employed to evaluate the conservatism of the RAM. The comparison revelated that the seismic responses computed using the RAM were consistent with those obtained using the refined method, since the averages of response ratio (defined as the ratio of the response by RAM to that of the refined method) approached 1.0, and the standard deviations of the response ratio were less than 5%. Finally, we found that applying a load factor of 1.1 to the response of the RAM allowed for a conservative design for seismic loads.

A Case Study of Decreasing Environment Pollution Caused by Energy Consumption of a Dormitory Building Which Only Using Electricity by Efficiently Simulating Applying Residential SOFC (Solid Oxide Fuel Cell)

  • Chang, Han;Lee, In-Hee
    • Architectural research
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 2019
  • Recent years in Korea, some new developed buildings are only using electricity as power for heating, cooling, bathing and even cooking which means except electricity, there is no natural gas or other kinds of energy used in such kind of building. In vehicle industry area, scientists already invented electric vehicle as an environment friendly vehicle; after that, in architecture design and construction field, buildings only using electricity appeared; the curiosity of the environment impact of energy consumption by such kind of building lead me to do this research. In general, electricity is known as a clean energy resource reasoned by it is noncombustible energy resource; however, although there is no environmental pollution by using electricity, electricity generation procedure in power plant may cause huge amount of environment pollution; especially, electricity generation from combusting coal in power plant could emit enormous air pollutants to the air. In this research, the yearly amount of air pollution by energy using under traditional way in research target building that is using natural gas for heating, bathing and cooking and electricity for lighting, equipment and cooling is compared with yearly amount of air pollution by only using electricity as power in the building; result shows that building that only uses electricity emits much more air pollutants than uses electricity and natural gas together in the building. According to the amount of air pollutants comparison result between two different energy application types in the building, residential SOFC (Solid oxide fuel cell) is simulated to apply in this building for decreasing environment pollution of the building; furthermore, high load factor could lead high efficiency of SOFC, in the scenario of simulating applying SOFC in the building, SOFC is shared by two or three households in spring and autumn to increase efficiency of the SOFC. In sum, this research is trying to demonstrate electricity is a conditioned environment friendly energy resource; in the meanwhile, SOFC is simulated efficiently applying in the building only using electricity as power to decrease the large amount of air pollutants by energy using in the building. Energy consumption of the building is analyzed by calibrated commercial software Design Builder; the calibrated mathematical model of SOFC is referred from other researcher's study.

A Study on the Application of the DVR in AC Electric Traction System (전기철도계통에 순간전압강하 보상장치 적용에 관한 연구)

  • 최준호;김태수;김재철;문승일;남해곤;정일엽;박성우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.95-104
    • /
    • 2003
  • The electric traction systems are quite differ from general power systems which is single-phase and heavy load. Therefore, there are inevitably power quality problems such as steady state or transient voltage drop, voltage imbalance and harmonic distortion. Among these problems, since steady-state volatge drop is the one of most important factor in electric power quality, many researches about on the compensation of volatge drop by using SVC(Static Var Compensator) and/or STACOM(Static Compensator) have been studied and proposed Also, it is expected that transient voltage drop(voltage sag) could affect the control and safety of high speed traction load. In this paper, voltage sag compensation of AT(Auto Transformer) feeding system are studied The detailed transient models of utility source, scott transformer, AT, and traction load are estabilished. The application of DVR(Dynamic Voltage Restorer) in electric traction system is proposed to compensate the voltage sag of traction network which is occured by the fault of utility source. It can be shown that application of the DVR in electric traction system is very useful to compensate the volatge sag from the result of related simulation works.

Characteristics of Small Hydro Power Resources for River System (수계별 소수력자원의 특성)

  • Park, Wansoon;Lee, Chulhyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.193.1-193.1
    • /
    • 2010
  • Small hydropower resources for five major river systems have been studied. The model, which can predict flow duration characteristic of stream, was developed to analyze the variation of inflow caused from rainfall condition. And another model to predict hydrologic performance for small hydropower(SHP) plants is established. Monthly inflow data measured at Andong dam were analyzed. The predicted results from the developed models in this study showed that the data were in good agreement with measured results of long term inflow at Andong dam. It was found that the models developed in this study can be used to predict the available potential and technical potential of SHP sites effectively. Based on the models developed in this study, the hydrologic performance for small hydropower sites located in river systems have been analyzed. The results show that the hydrologic performance characteristics of SHP sites have some difference between the river systems. Especially, the specific design flowrate and specific output of SHP sites located on North Han river and Nakdong river systems have large difference compared with other river systems.

  • PDF

EEG Fast Beta Sub-band Power and Frontal Alpha Asymmetry under Cognitive Stress

  • Sohn, Jin-Hun;Park, Mi-Kyung;Park, Ji-Yeon;Lee, Kyung-Hwa
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2001.05a
    • /
    • pp.225-230
    • /
    • 2001
  • Intensity of background noise is a factor significantly affecting both subjective evaluation of experienced stress level and associated electroencephalographic (EEG) responses during mental load in noisy environments. In the study on 27 subjects we analyzed the influence of the background white noise (WN) intensity on psychophysiological responses during a word recognition test. Electrocortical activity were recorded during baseline resting state and 40 s long performance on 3 similar Korean word recognition tests with different intensities of background WN (55, 70 and 85 dB).. An important finding in terms of physiological reactivity was similarity of all physiological response profiles between 55 and 70dB WN, i.e., none of physiological variables differentiated the two conditions, while 85dB WN resulted in a significantly different profile of reactions (higher fast beta power in EEG spectra). This condition was characterized by highest subjective rating of experienced stress, had more fast beta activity and had tendency of right hemisphere dominance, emphasizing the role of brain lateralization in negative affect control.