• Title/Summary/Keyword: Load power factor

Search Result 847, Processing Time 0.034 seconds

Novel Current Compensation Technique for Harmonic Current Elimination (고조파 전류 제거를 위한 새로운 전류 보상 기법)

  • Jeong Gang-Youl
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.587-591
    • /
    • 2004
  • This paper proposes a novel current compensation technique that can eliminate the harmonic currents included in line currents without computation of harmonic current components. A current controller with fast dynamics for an active filter is described. Harmonic currents are directly controlled without the need for sensing and computing the harmonic current of the load current, thus simplifying the control system. Current compensation is done in the time domain, allowing a fast time response. The DC voltage control loop keeps the voltage across the DC capacitor constant. High power factor control by an active filter is described. All control functions are implemented in software using a single-chip microcontroller, thus simplifying the control circuit. Any current-controlled synchronous rectifier can be used as a shunt active filter through only the simple modification of the software and the addition of current sensors. It is shown through experimental results that the proposed controller gives good performance for the shunt active filter.

  • PDF

Finite Element Analysis of L.I.M. Considering the Voltage as a Driving Source (전압을 구동함수로 한 선형 유도전동기의 유한요소 해석)

  • 임달호;최창규
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.3
    • /
    • pp.250-257
    • /
    • 1991
  • In the analysis of the electric machine by finite element method, the primary current has been selected as a driving source. But the voltage is constant and the primary current varies according to the load condition in the pracdtical system. Therefore, in this paper, magnetic flux distribution, primary current, input effective power, power factor, efficiency and propulsion force of S.L.I.M. were calculated by the finite element method cnsidering the voltage as a driving source. Because the driving characteristics could not be measured in the S.L.I.M., voltage-current curve, 3-phase current curve, and propulsion force were measured at the starting and they were compared with theoretical values.

Harmonics and Power Factor Controller for Single-Phase PWM Converter Using Two Input Sensors (2개의 입력센서를 갖는 단상 PWM 컨버터용 고조파 및 역률 제어기)

  • Jeon Young-Soo;Lee Kyung-Bin;Han Byung-Moon;Han Hoo-Sek
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.10
    • /
    • pp.618-624
    • /
    • 2004
  • In this paper, a new controller for a single-phase PWM converter is described, which requires only two input parameters, the dc voltage and the ac current. Detail simulation model with EMTDC(Electro-Magnetic Transient program for DC transmission) including power circuit and controller was developed to verify the operation of proposed controller. The application feasibility of the proposed controller was verified through experimental works with a prototype. The proposed controller has a simple structure in the point of hardware implementation, and shows excellent performance in normal operation as well as in sudden load change.

HIGH-FREQUENCY APWM THREE-PHASE AC CHOPPER (고주파 비대칭 PWM 3상 교류초퍼)

  • Kim, Han-Sang;Choe, Gyu-Ha;Kim, Yong-Ju;Lee, Keun-Ha;Baek, Hyung-Lae
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.535-539
    • /
    • 1989
  • A high-frequency asymmetrical PWM control technique is proposed which can improve the input power factor of ac chopper and also suppress its harmonic contents of currents at both its input and load sides and the acoustic noises by its switching semiconductor devices. The ideal switching function for the proposed technique is derived and hence converted into asymmetrical PWM pattern for practical implementation of ac voltage regulator. Also the various power circuits of three phase AC choppers are suggested. The theoretical characteristics of the proposed PWM technique are investigated by digital simulation.

  • PDF

Evaluation of Structural Stability of JIB Crane for a Feed Vessel According to the Luffing Angle (러핑각도에 따른 선박용 지브크레인의 구조 안정성 평가)

  • Lee, M.J.;Han, D.S.;Han, G.J.
    • Journal of Power System Engineering
    • /
    • v.12 no.6
    • /
    • pp.24-28
    • /
    • 2008
  • It expects demand of ships which equipped with JIB crane growth to continue. However, demand of JIB crane is increased, domestic shipment company imitated the design of Europe and Japan. And we need to develop the functional system of the JIB crane and modernize it. We need to find the optimum luffing angle for saving energy when JIB crane works. This study analyzed buckling load of JIB and reaction force of support point and stress of JIB according to the luffing angle through finite element analysis when JIB crane loads 40 ton weight. And this study considered the safety factor 1.8 of material. Every design condition was KS A1627 standard. This study used ANSYS 10.0.

  • PDF

Probabilistic Evaluation Methodology for Nuclear Components (원전 주요기기의 확률론적 평가 기법)

  • Lee, Joon-Seong;Kwak, Sang-Log;Kim, Young-Jin;Park, Youn-Won
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.459-464
    • /
    • 2001
  • For major nuclear power plant components periodic inspections and integrity assessments are needed for the safety. But many flaws are undetectable due to sampling inspection. Probabilistic integrity assessment is applied to take into consideration of uncertainty and variance of input parameters arise due to material properties, applied load and undetectable flaws. This paper describes a Probabilistic Fracture Mechanics(PFM) analysis based on Monte Carlo(MC) algorithms. Taking important parameters as probabilistic variables such as fracture toughness, crack growth rate and flaw shape, failure probability of major nuclear power plant components is archived as a results of MC simulation. For the verification of these analysis, a comparison study of the PFM analysis using other commercial code, mathematical method is carried out and a good agreement was observed between those results.

  • PDF

INNOVATIVE INDUCTION-HEATED HIGH-TEMPERATURE STEAMER USING VOLTAGE-FED HIGH-FREQUENCY RESONANT INVERTER

  • Guo, Bin;Nakamizo, Tetsuo;Nishida, Katsumi;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.586-591
    • /
    • 1998
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction-based fluid heating appliance using voltage-fed series capacitor-compensated load resonant high-frequency IGBT inverter with a phase-shifted PWM and a power factor correction schemes. Its operating characteristics in steady-state and dynamic state are illustrated including unique features and evaluated on the basis of its computer simulation and experimental results of 10kw breadboard appliance developed for hot water producer and superheated steamer.

  • PDF

Topology of Single-Phase PFC Rectifier Circuit with Sinusoidal of Input Current (입력전류의 정현화에 의한 단상PFC정류회로의 토폴로지)

  • Lee, S.H.;Kim, Y.M.;Kwon, S.K.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.290-293
    • /
    • 2002
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. However, most of these employ switching devices, such as FETs and the like. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor connection scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and experimental implementations.

  • PDF

Development of the 300kVA Large Capacity IGBT UPS (IGBT를 적용한 300kVA급 대용량 무정전전원장치 개발)

  • Byun, Y.B.;Kim, T.J.;Joe, K.Y.;Park, S.J.;Kim, C.U.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2057-2059
    • /
    • 1998
  • In order to maintain a high quality output voltage, conventional UPS systems use complex filters with large passive components. To overcome this drawback, real time feedback control schemes have been invested. However, these techniques require a high inverter switching frequency to dynamically adapt to changing load conditions reduce harmonics of the output voltage, thereby rendering the system inadequate for high power applications. This paper presents real time digital signal processor(DSP) control of a large capacity UPS system feeding nonlinear loads to provide a sinusoidal inverter output voltage, unity input power factor, low bus voltage ripple, and excellent transient response.

  • PDF

The Photovoltaic generation control system using partial resonant method (부분공진기법을 이용한 태양광발전 제어시스템)

  • 고강훈;이현우;김영철;최광주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.16-22
    • /
    • 2000
  • This paper describes Transformer-less type utility interactive system that is combined with buck/boost chopper applying partial resonant method, which remove Transformer, and high efficient PWM inverter. Therefore, it is possible to make it lightweight, to cut down the cost, and to improve its reliability. What the merits of this system are that we can transmit arbitrary power arbitrary power to load and utility regardless of generating voltage magnitude of solar cell and we can always obtain high factor controlling by equal phase signal with utility.

  • PDF