• 제목/요약/키워드: Load power factor

검색결과 847건 처리시간 0.036초

Analytical Study on Improvement in Load Sharing for Planetary Gear Set using Floating Ring Gear

  • Chung, Woo-Jin;Choi, Kyujeong;Oh, Jooseon;Park, Young-Jun;Lee, Ki-Hun
    • Journal of Biosystems Engineering
    • /
    • 제43권4호
    • /
    • pp.263-272
    • /
    • 2018
  • Purpose: The load on the planet gear of a planetary gear set is uniformly distributed. However, manufacturing and assembly errors cause uneven load sharing in the planetary gear set. To solve this problem, most studies have suggested applying a floating sun gear to the planetary gear set. However, the effect of the floating ring gear and floating carrier has not been extensively studied. This study aimed to investigate the effect of the floating ring gear. Methods: Two models were developed; one was the fixed ring gear model, and the other was the floating ring gear model. In the fixed ring gear model, the clearance between the ring gear and the housing was $0{\mu}m$, and in the floating ring gear model, the clearance was from $10{\mu}m$ to $100{\mu}m$. The load sharing of the planetary gear set was evaluated by the load sharing factor. Results: Our study showed that with increase in clearance, the load sharing factor of the planetary gear set approached unity. In addition, when the clearance increased above a certain level by which a fully floating ring gear was achieved, the load sharing factor was not affected by the clearance. Conclusions: This indicates that the fully floating ring gear increased the power density of the planetary gearbox by uniformly dividing the load of the planetary gear set. For this reason, the size of the gearbox could be decreased by using a fully floating ring gear.

불평형 전압 동작시 전력 커패시터 특성 분석 (Characteristics Analysis of Power Capacitor with Unbalanced Voltage Operation)

  • 김종겸;박영진;이은웅
    • 조명전기설비학회논문지
    • /
    • 제22권5호
    • /
    • pp.64-72
    • /
    • 2008
  • 3상 4선식 전원공급에서 부하의 불평형 운전에 의한 전압 불평형은 전류 불평형을 일으켜 기기의 손실증가에 따른 출력 감소로 전원용량을 증가시키는 것은 물론이고 전기 품질에도 나쁜 영향을 미치고 있다. 전력용 커패시터는 유도성 부하의 역률 보상과 전원을 안정시키기 위해 사용되며, 유도전동기의 여자에 필요한 자화성분을 전원을 대신하여 제공하기도 한다. 전압 불평형이 지속될 경우 커패시터에 전압 스트레스로 작용하여 절연 고장을 일으킬 수 있다. 본 논문에서는 역률 개선용 커패시터가 전압 불평형 증가에 의해 받는 영향을 해석한 결과 전압 및 전류의 크기가 함께 증가하여 스트레스는 점차적으로 높아진다는 것을 확인할 수 있었다.

주택 및 사무용 빌딩 내 전기기기의 전력 수요 패턴 분석 (Power demand pattern analysis for electric appliances in residential and commercial building)

  • 노성준;이순정;이상우;김광호
    • 산업기술연구
    • /
    • 제30권A호
    • /
    • pp.9-15
    • /
    • 2010
  • Recently, Smart Grid is a emerging topic in power and communication industry. Smart Grid refers to a evolution of the electricity supply infrastructure that monitors, protects, and intelligently optimize the operation of the interconnected elements including various type of generators, power grid, building/home automation system and end-use consumers. In order to successful implementation of Smart Grid, energy management function will be the key factor that coordinates and optimally controls the various loads according to the operating condition and environments, and the load patterns in residential and commercial building will be required as fundamental element for load management. In this study, we collects many types of energy usage data of electric appliances, analyze their load curves, and make the general load patterns for electrical appliance.

  • PDF

A New Single-Stage PFC AC/DC Converter with Low Link-Capacitor Voltage

  • Lee, Byoung-Hee;Kim, Chong-Eun;Park, Ki-Bum;Moon, Gun-Woo
    • Journal of Power Electronics
    • /
    • 제7권4호
    • /
    • pp.328-335
    • /
    • 2007
  • A conventional Single-Stage Power-Factor-Correction (PFC) AC/DC converter has a link capacitor voltage problem under high line input and low load conditions. In this paper, this problem is analyzed by using the voltage conversion ratio of the DC/DC conversion cell. By applying this analysis, a new Single-Stage PFC AC/DC converter with a boost PFC cell integrated with a Voltage-Doubler Rectified Asymmetrical Half-Bridge (VDRAHB) is proposed. The proposed converter features good power factor correction, low current harmonic distortions, tight output regulations and low voltage of the link capacitor. An 85W prototype was implemented to show that it meets harmonic requirements and standards satisfactorily with near unity power factor and high efficiency over universal input.

RESEARCH OF AN ACTIVE FILTER BASED BALANCED POWER SUPPLY SYSTEM FOR RAIL WAY TRACTION

  • Zeng, Guohong;Hao, Rongtai
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.797-801
    • /
    • 1998
  • This paper presents a balanced 3/1 supply scheme for electric railway. By employing an active filter, the current of the three-phrase delivery system is balanced while the load is single phrase, which makes it possible for the traction system to behave like a pure-resistance load, with unity power factor and no harmonics. Simulation results are present to verify the scheme's topology and control strategies.

  • PDF

고역률 LED 구동회로의 효율화에 관한 연구 (A Study on the Efficiency of a High Power Factor LED Driver Circuit)

  • 이동원;김병철
    • 한국전기전자재료학회논문지
    • /
    • 제26권8호
    • /
    • pp.629-634
    • /
    • 2013
  • The rectified voltage supplied to LED lamp is used in load and then the surplus voltage can be produced in LED lighting. In this case, LED lighting is proposed that can recyclable the excess voltage to supply power to the controller.

선형 및 비선형 부하 사용시 전류 및 부하불평형률에 대한 연구 (A Study on the Current & Load Unbalance Factor in using Linear & Nonlinear Load)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1291-1296
    • /
    • 2017
  • Single-phase and three-phase load can be used together in 3-phase 4-wire system. Single-phase and three-phase loads can be classified as linear loads without harmonics and nonlinear with harmonics. Single-phase linear loads are linear loads such as lamps and heat, and single-phase nonlinear loads are power converters such as rectifiers. It is recommended that the distribution of loads in the 3-phase, 4-wire distribution lines be evenly distributed within a certain range. However, harmonic currents generated in a nonlinear load flow on the neutral line and affect the phase current magnitude. The difference in the magnitude of the individual phase current due to the influence of the harmonic current present in the neutral line can produce a difference in current and load unbalance. In this study, current unbalance ratio and load unbalance ratio which can occur when a combination of linear and nonlinear loads are applied to 3-phase 4-wire distribution line are calculated.

전류원 방식 푸시-풀 공진형 인버터로 구성된 단일단 고역률 형광등용 전자식 안정기 (Electronic Ballast using Current-Fed Push-Pull Resonant Inverter with Single-Stage Power Factor Correction Circuit)

  • 채균;류태하;조규형
    • 전력전자학회논문지
    • /
    • 제5권5호
    • /
    • pp.501-507
    • /
    • 2000
  • 형광등용 전자식 안정기의 개발에 있어서, 최근 선전류 고조파 성분의 제한에 관한 여러 가지 규제를 만족시키기 위해 역률 개선 회로를 부가하는 것이 권장되고 있다. 본 논문에서는 자려식 전류원 방식 푸시-풀 공진형 인버터의 전력 트랜스포머의 2차측과 별도의 한 개의 커패시터를 사용함으로써 역률 개선을 수동소자로만 이용하여 전류원 방식의 공진형 인버터를 채택하는 형광등용 전자식 안정기를 저가격화, 고역률화하는 것을 목적으로 한다.

  • PDF

분산전원이 설치 된 배전 계통의 분포부하를 이용한 IVVC알고리즘 (Integrated Voltage/Var control based on Distributed Load Modeling with Distributed Generation in Distribution System)

  • 김영인;임일형;최면송;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.95_96
    • /
    • 2009
  • In this paper, a new algorithm of Integrated Volt/Var Control (IVVC) is proposed using Volt/Var control for the Distribution Automation System (DAS) based on the modeling of the distributed load and the distributed current. In the proposed, the load flow based on the modeling of the distributed load with Distributed Generation and the distributed current are estimated from constants of four terminals using the measurement of the current and power factor from a Feeder Remote Terminal Unit (FRTU). For Integrated Volt/Var Control (IVVC), the gradient method is applied to find optimal solution for tap and capacity control of OLTC (On-Load Tap Changers), SVR (Step Voltage Regulator), and SC (Shunt Condenser). What is more Volt/Var control method is proposed using moving the tie switch as well as IVVC algorithm using power utility control. In the case studies, the estimation and simulation network have been testified in Matlab Simulink.

  • PDF

고조파 왜곡 환경에서 향상된 역률 계측 알고리즘 개발 (Development of advanced Power Factor Computation Algorithm in Harmonics distorted Distribution System)

  • 이현우;박영균;이진한;정상현;박철우
    • 전자공학회논문지
    • /
    • 제53권7호
    • /
    • pp.121-127
    • /
    • 2016
  • 본 논문에서는 고조파로 전압과 전류가 왜곡된 상황에서 정확하게 기본파의 역률을 측정할 수 있는 방법을 제안한다. 제안한 역률 계측 방법에서는 전압과 전류를 DQ회전좌표계로 변환한 후 유효전력과 무효전력을 계산하여 역률값을 구하게 된다. 기존의 역률 계측방법과 제안한 방법을 수식적으로 비교하여 제시하고, 제안한 방법은 전압과 전류 모두 고조파 왜곡된 상황에서도 기본파의 역률을 정확하게 계측할 수 있는 것을 MATLAB을 이용한 모의실험에서 확인한다. 제안한 역률 계측방법을 자동역률제어장치에 적용할 경우 고조파 왜곡 환경에서 역률 보상 성능을 최대화 할 수 있다. 그 결과 수용가에서는 역률 개선을 통한 전기료 감소, 선로손실 감소, 부하 용량 증대 효과가 기대된다. 특히 발전 사업가 측에서는 역률 보상 성능의 향상으로 송전 여유 용량 확보와 발전량 절감이 가능하다.