• Title/Summary/Keyword: Load measurement system

Search Result 700, Processing Time 0.035 seconds

A Study about the Influence of Pollutant Load on Water Quality in a Small Stream Watershed (소하천의 오염부하량이 수질에 미치는 영향에 관한 연구)

  • Lee, Sang-Hoon;Cho, Wook-Sang
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.1
    • /
    • pp.9-19
    • /
    • 2001
  • An intensive watershed survey including water quality measurement of 6 times was carried out in order to find out the relationship between pollutant load and water quality in a small stream watershed where livestock wastewater is the main source of water pollution. The findings from the survey are as follows. 1) The number of livestock showed large disagreement among county office, myon, and insite survey. It is vital to check the data at the beginning of watershed survey. 2) The fluctuation of streamflow and water quality was so large depending on the day of measurement that it is essential to set up continuous telemetering system to get reliable data about delivery ratio of pollutants. 3) It was helpful for setting the priority of investigation to check water quality and quantity at several points along the stream after dividing the watershed into 5 drainage areas. 4) To control the livestock wastewater, especially in case of cows, it is necessary to have roof system and prevent overland flow from the ground. In case of pig farms, it is recommended to have public treatment system instead of private treatment system. The exact emission load of livestock wastewater was difficult to estimate, and requires more study.

  • PDF

Reasonable Load Characteristic Experiment for Component Load Modeling (개별 부하모델링을 위한 부하의 합리적인 특성실험)

  • Ji, Pyeong-Sik;Lee, Jong-Pil;Im, Jae-Yun;Chu, Jin-Bu;Kim, Jeong-Hun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.2
    • /
    • pp.45-52
    • /
    • 2002
  • Load modeling is classified into two methods according to approaching method, so called the measurement and component-based method. The measurement method is to model the load characteristics measured directly at substations and feeders. But it is difficult to measure continuously load characteristics from naturally occurring. system variation. The component-based method consists of the fellowing process; component load modeling, composition rate estimation and aggregation of component loads, etc. In this paper, the characteristic experiment of component loads was performed to obtain data for the component load modeling as the component-based method. At first, representative component loads were selected by the proposed method considering the accuracy of load modeling and the performance possibility of component load experiment in the laboratory. Also an algorithm was Proposed to identify the reliability of data obtained from the component load characteristic experiments. In addition, the results were presented as the case studies.

Impact of Dynamic Load Model on Short-Term Voltage Stability of Korea Power System and Estimation of Dynamic Load Model Parameters (국내 계통의 단기 전압 안정도에 대한 부하 모델의 영향성 검토 및 부하 모델 파라미터 선정)

  • Moon, Jaemin;Kim, Jae-Kyeong;Hur, Kyeon;Nam, Suchul;Kim, YongHak
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • In this paper, we analyzed the effect of power system load model on the short-term voltage stability analysis results. First, we introduced common load models. We also confirmed that some load models can not represent actual system phenomena even if the model parameters are optimized. Also, we studied about the influences of load parameters and regional characteristics of load model on the sort-term voltage stability of KEPCO power system considering the contingency. The results showed that the importance of selecting a load model was confirmed again. And we recognized about it can be understood that it should reflect the load characteristics of the area near the assumed contingency more accurately.

Development of Measurement System of Cutter Conditions for Combine Diagnosis (I) - Analysis of Vibration and Load Signals - (콤바인 예취부 고장진단을 위한 예취 칼날부의 진단 시스템 개발(I) - 진동 및 부하 신호 분석 -)

  • Choi, Chang-Hyun;Kim, Yong-Joo;Kim, Jong-Hyuck;Mun, Joung-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.32 no.3
    • /
    • pp.190-196
    • /
    • 2007
  • The purpose of this study is to develop a measurement system of cutter conditions for combine header diagnosis during rice harvesting. A load cell was installed at the locker-arm to measure load fluctuation and an acceleration senor was used to monitor vibration signal of cutter bar. The data were collected from a paddy field during harvesting. The tests were conducted with a normal cutter, a loosened cutter, a broken cutter, and a worn-out connecter pin at the field. The vibration signals converted by FFT (Fast Fourier Transformation), filtered, and normalized. The load data and peak values of vibration signals in four different frequency ranges were used to determine the cutting operation and the cutter conditions of combine. The multiple comparison tests showed that the load data and peak values of vibration signals were important to monitor the cutting operation and cutter conditions of combine header.

A Study on Decentralized under Voltage Load Shedding Scheme for Preventing Wide-area Black Out (광역정전 예방을 위한 분산형 부하 제어 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • An electric power system sometimes fails because of disturbances that occur unexpectedly, such as the uncontrolled loss of load that developed from cascading blackout. Which make stability through a little of under voltage load shedding should work. The development of phasor measurement unit(PMU) makes network supervision possible. The information obtained from PMU is synchronized by global positioning system(GPS). There are many real-time algorithms which are monitoring the voltage stability. This paper presents the study on the VILS(Voltage Instability Load Shedding) using PMU data. This algorithm computes Voltage Stability Margin Index(VSMI) continuously to track the voltage stability margin at local bus level. The VSMI is expressed as active and reactive power. The VSMI is used as an criterion for load shedding. In order to examine the algorithm is effective, applied to KEPCO system.

Development of an Input Force Measuring Method for Vehicle Tests (실차 주행중 입력하중 계측 기법 개발)

  • Lee, Kwang Chun;Kim, Seung Han;Lee, Kang In;Bae, Byung Kook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.2
    • /
    • pp.143-147
    • /
    • 2017
  • In this study, a driving load measuring method has developed without utilizing WFT. To measure the driving load, we developed a three-axis load cell with a strain gage. A method to verify the performance of load cells was developed. A system to measure the input load was proposed, and it was verified by evaluation. The measurement error of the impact road surface was found to be less than 20%. However, except under impact road surface conditions, the proposed system can be applied for actual vehicle input load measurement. The influence of tire evaluation tests were carried out through the handling verification evaluation. The input load measurement methods proposed in the present study make performance verification possible without using WFT.

Harmonics Reduction in Load control and Management system

  • Thueksathit, W.;Tipsuwanporn, V.;Hemawanit, P.;Gulpanich, S.;Srisuwan, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2283-2286
    • /
    • 2003
  • This paper presents conservation of electrical energy in building with harmonics analysis and compensation which occur in electrical system. We use load controlling and management system in order to adjust load factor of system.The maximum demand limiting and controlling are used ,then the system can acquire the prediction and compare it to the maximum demand set point.The electrical signal analysis based on FFT technique. The harmonics are compensated by using harmonic filters.This system consists computer which works as controller, processor , analysis and database unit together with digital power meter in form of multidrop network through serial communication via RS-485.The load control system uses PLC to control load via serial communication RS-485. The A/D converter is used for sampling the electrical signals via parallel port of computer.The harmonic filters are controlled by a computer.The data of measurement such as voltage, current, power, power factor, total harmonic distortion, energy, etc., can be saved as database and analysis. The load factor is adjusted by limiting and controlling maximum demand. The load factor adjustment can reduce the cost of electric consumption and energy generation together with harmonics compensation in order to increase high efficiency of electrical system.

  • PDF

Development of Hybrid Prototype Dual Load Cell Structure (하이브리드 프로토타입 듀얼 로드 셀 구조 개발)

  • Ham, Juh-Hyeok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.6
    • /
    • pp.373-380
    • /
    • 2020
  • We have developed the hybrid prototype load cell structures. These developed load cell structures may increase the reliability of the load sensing by deriving the load values through the double sensing method through the vertical maximum deflection and bending stress of the simple beams. For this purpose, the structure design was performed so that the load value, the deflection and stress value could be output to the same value through the optimal structure design. The structurally designed dimensions reaffirmed the accuracy of the design through the structural analysis program and the matching of the load value and the deflection value. Based on the designed structural dimension, the prototype form was constructed through laser cutting and production using hot rolled steel materials. The developed prototype load cell structure can be used as good educational material in various subjects such as material mechanics, steel structure design, measurement engineering, and mechatronics engineering. It is also believed that the measurement system ideas can inform the occurrence of errors in the event of a problem, and if a major accident caused by a sensing error is predicted, it will show good utilization to prevent accidents.

Evaluation of the Spring Constant of a Micro Coil Spring (마이크로 코일 스프링의 스프링 상수 평가)

  • Lee J. K.;Jeon B. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.255-259
    • /
    • 2001
  • The spring constant of a micro coil spring was measured by uniaxial tensile test. The inner diameter of it is $35{\mu}m$ and the pitch size is about $23{\mu}m$. A suing constant measurement system was developed. It consists of control units, load cell units, linear stages and several specially designed jigs and fixtures. Load and displacement are measured using a commercial load cell of 1000g capacity and a magnetic scale of $0.5{\mu}m$ resolution. In this study, a method to measure the spring constant of micro coil spring is presented and the relationship between misalignment of specimen and measurement error is discussed.

  • PDF

Comparative Study on Proposed Simulation Based Optimization Methods for Dynamic Load Model Parameter Estimation (동적 부하모델 파라미터 추정을 위한 시뮬레이션 기반 최적화 기법 비교 연구)

  • Del Castillo, Manuelito Jr.;Song, Hwa-Chang;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.187-188
    • /
    • 2011
  • This paper proposes the hybrid Complex-PSO algorithm based on the complex search method and particle swarm optimization (PSO) for unconstrained optimization. This hybridization intends to produce faster and more accurate convergence to the optimum value. These hybrid will concentrate on determining the dynamic load model parameters, the ZIP model and induction motor model parameters. Measurement-based parameter estimation, which employs measurement data to derive load model parameters, is used. The theoretical foundation of the measurement-based approach is system identification. The main objective of this paper is to demonstrate how the standard particle swarm optimization and complex method can be improved through hybridization of the two methods and the results will be compared with that of their original forms.

  • PDF