• Title/Summary/Keyword: Load management

Search Result 2,146, Processing Time 0.023 seconds

A Study on the Development of ADWHM(Advanced Digital Watt-Hour Meter) (차세대 디지털 적산전력계 개발에 대한 연구)

  • Ko, Yun-Seok;Yun, Sang-Moon;Seo, Seong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.262-264
    • /
    • 2003
  • This paper develops an ADWHM(Advanced Digital Watt Hour Meter) based on RISK type'8bit micro-controller, which has voltage management data recording function, load management data recording function as well as the existing watt-hour data recording data function. It can enhance greatly the economics of the existing remote meter reading system. Also it can improve highly the quality of power supplied to the electric customer by minimizing the voltage management cost and by enhancing the efficiency of load management.

  • PDF

A Scalable Hybrid P2P MMOG Cloud Architecture for Load Management in a Region (영역내 부하 관리를 위한 확장적 하이브리드 P2P MMOG 클라우드 구조)

  • Kim, Jin-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.3
    • /
    • pp.83-91
    • /
    • 2022
  • This paper proposes a scalable hybrid P2P(peer-to-peer) cloud architecture for MMOGs(massively multiplayer online games) which includes load management schemes for each region. A game world is divided into several game regions and each game region is serviced by at least one peer(player) in this MMOG cloud environment. The load must be managed regionally to support smooth interactions among them even in the presence of a high concentration of players in a specific region. In the proposed architecture where an efficient and effective provisioning of resources is realized, it is suitable for players to interact with cloud servers effectively and it avoids bottlenecks of the current client-server MMOG architecture. This architecture also relieves a lot of computational power and network traffic, the load on the servers in the cloud by exploiting the capacity of the players. Simulation results show that the proposed hybrid P2P cloud architecture can reduce the considerable bandwidth at the server compared to the client server architecture as the available resources grow with the number of players in crowding or hotspots.

Improvement and Implementation to Enhance the Effectiveness of the Total Pollution Load Control System (수질오염총량관리제 실효성 제고를 위한 제도개선 및 추진 방향)

  • Seok-Gyu Kim;Seung-Young Oh;Su-Young Park;Eun-Hye Na;Yong-Seok Kim
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.4
    • /
    • pp.343-355
    • /
    • 2023
  • After the implementation of the total pollution load control system, the effect of improving river water quality by expanding investments in basic environmental facilities, inducing operational efficiency, and reducing the load of various pollutants was clear. However, since the implementation of the system, the management of non-point pollutants has been neglected; management focused on specific substances (biochemical oxygen demand (BOD) and total phosphorus (T-P)) and lacked specific cause analysis and action plans, failed to establish a relationship between water quality and pollution load, failed to reflect stakeholder demands for river water quality management, and failed to apply technical conditions. Therefore, to overcome the limitations raised and achieve a practical and efficient advanced total pollution system, the current system was partially improved and will continue to be improved. This study analyzed the performance and limitations of the total pollution system and introduced recent improvements and the contents that are being improved. The main contents included reducing emissions and reduction monitoring, using water quality tele-monitoring system (TMS) data and self-measurement data, adding population-inducing facilities, and adjusting regional development projects from 20 to 30 multi-family housing units, currentizing each pollutant source according to the roadmap. If the system is improved in a developmental direction and responds to various changes, it will be a more practical and effective policy.

Changes in Characteristics of Sewer Flow & Its Water Quality from the Sewer Rehabilitation Area (하수관거 정비지역의 관거이송 유량 및 수질특성 변화)

  • Park, Jun Dae;Oh, Seung Young;Choi, Yun Ho;Kim, Yong Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.2
    • /
    • pp.196-208
    • /
    • 2015
  • This study analyzed the characteristics of sewer flow and its water quality, and investigated changes in the characteristics in three areas where the sewer rehabilitation projects have been carried out. In S1 area, the patterns of the flow became regular and the range of the fluctuation decreased after the sewer rehabilitation. The flow and its BOD concentration increased. The infiltration/inflow and exfiltration showed clear distinction before and after the sewer rehabilitation in this area. In S2 area, the patterns and the range of the fluctuation of the flow made no differences before and after the sewer rehabilitation. The flow decreased slightly and its BOD concentration increased considerably after the sewer rehabilitation. Big decrement in stormwater inflow but small in exfiltration appeared in this area. In S3 area, the patterns and the range of the fluctuation of the flow made no differences before and after the sewer rehabilitation. The flow decreased slightly and its BOD concentration increased in a small rate in this area.

A Study on the Introduction of a Total Pollutant Load Management System in Gwangyang Bay, Korea (광양만 특별관리해역의 연안오염총량관리 도입에 관한 연구)

  • Kim, DoHee;Park, JongSick;Han, KiWon;Cho, HyeonSeo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.899-905
    • /
    • 2022
  • Seawater management via Total Pollutant Load Management System (TPLMS) is crucial because it enables local governments to optimally allocate pollutant loads in order to best reduce pollutant load burden while supporting reasonable development. This study analyzed the feasibility of introducing a TPLMS on Gwangyang Bay, a specially managed sea area. We researched the inflow of pollutants and analyzed the present state of seawater quality in Gwangyang Bay and then discussed our findings and reviewed other specially managed sea area with the Gwangyang Bay Advisory Committee. We conclude that TPLMS on Gwangyang Bay is needed and suggest checking economic feasibility, ef iciency, and conducting continuous monitoring of seawater quality indicators such as chemical oxygen demand (COD), total nitrogen (TN), total phosphorus (TP), heavy metals and polcyclic aromatic hydrocarbons (PAHs) prior to introducing a TPLMS in Gwangyang Bay.

Assessing the Unit Load Reduction Equation of Drainage Outlet Raising Management in Paddy Fields (논 물꼬관리 기법 적용에 따른 원단위 삭감부하량 산정식 평가)

  • Kim, Dong-Hyeon;Oh, Heung-Keun;Jang, Taeil;Ham, Jong-Hwa
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.2
    • /
    • pp.35-45
    • /
    • 2023
  • The DOR (Drainage outlet raising) in the paddy field has been suggested as one of the most important best management practices for the TMDL (Total maximum daily load) management in the technical guidelines by the NIER (National institute of environmental research). However, this method is underestimated and is not well adopted by local governments for the TMDL. The purpose of this study is to evaluate the unit load reduction equation according to the application of DOR in order to expand this equation. The original equation in the guideline was derived using the HSPF (Hydrological Simulation Program-Fortran) model for 1 year in Changnyeong. We analyzed the reduction effect of the original equation application by collecting additional long-term monitoring data from the Buan, Icheon, Iksan, and Jeonju. When comparing the reduction loads between the original equation and monitoring results, the evaluation results of the original equation were 11% of the monitoring analysis results, which was underestimated. This means that the original equation needs to be improved. For assessing the equation, the HSPF Paddy-RCH model was established according to the NI ER guideline and evaluated for applicability. The performance results of the model showed a reasonable range by the statistical criteria. Modified equations 1 and 2 were proposed based on the monitoring and modeling results. Modified equation 1 was the method of modifying the original equation's main factors, and modified equation 2 was the method of applying the non-point pollution reduction efficiency according to the rainfall class using the long-term modeling results. At the level of 58.6~64.6% of monitoring data, the difference between them could be further reduced compared to the original equation. The suggested approach will be more reasonable and practicable for decision-makers and will contribute to the TMDL management plans.

Kalman-Filter Based Static Load Modeling of Real Power System Using K-EMS Data

  • Lee, Soo-Hyoung;Son, Seo-Eun;Lee, Sung-Moo;Cho, Jong-Man;Song, Kyung-Bin;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.304-311
    • /
    • 2012
  • So far, the importance for an accurate load model has been constantly raised and its necessity would be further more emphasized. Currently used load model for analysis of power system in Korea was developed 10 years ago, which is aggregated by applying the statistically estimated load compositions to load models based on individual appliances. As modern appliances have diversified and rapidly changed, the existing load model is no longer compatible with current loads in the Korean power system. Therefore, a measurement based load model is more suitable for modern power system analysis because it can accurately include the load characteristics by directly measuring target load. This paper proposes a ZIP model employing a Kalman-filter as the estimation algorithm for the model parameters. The Kamlan-filter based parameter identification offers an advantage of fast parameter determination by removing iterative calculation. To verify the proposed load model, the four-second-interval real data from the Korea Energy Management System (K-EMS) is used.

A Study on the Effective Enhancement of the Load Power Factor Using the Load Power Factor Sensitivity of Generation Cost (부하역률 감도기법 적용에 의한 효율적인 부하역률 개선에 관한 연구)

  • Lee Byung Ha;Kim Jung-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.1
    • /
    • pp.18-24
    • /
    • 2005
  • Various problems such as the increase of the power loss and the voltage instability may often occur in the case of low load power factor. The demand of reactive power increases continuously with the growth of active power and the restructuring of electric power companies makes the comprehensive management of reactive power a troublesome problem, so that the systematic control of load power factor is required. In this paper, the load power factor sensitivity of the generation cost is derived and it is used for determining the locations of reactive power compensation devices effectively and for enhancing the load power factor appropriately. In addition, the voltage variation penalty cost is introduced and the integrated costs including the voltage variation penalty cost are used for determining the value of the load power factor from the point of view of the economic investment and voltage regulation. It is shown through the application to a large-scale power system that the load power factor can be enhanced effectively and appropriately using the load power factor sensitivity and integrated costs.

Implementation of Real-Time Wireless Web Server Load Monitoring System

  • Park, Hong-Jin;Kwon, Chang-Hee
    • 한국디지털정책학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.211-219
    • /
    • 2004
  • Due to rapid increases in Internet users, it becomes essential to provide well-established web services and monitor web server's load for the sake of reliable web server management. The existing web server load monitoring has been based on such cable methods as RPC, RMI, CORBA and etc. But it has the limitation in bringing information both anywhere and anytime over the Internet. This thesis is aimed to realize real-time wireless web server monitoring system based on Wireless Application Protocol (WAP). As any user can log on wirelessly to the Internet at any time through wireless terminals like PDA, the realization will make possible instant and real-time web server monitoring.

  • PDF