• Title/Summary/Keyword: Load management

Search Result 2,146, Processing Time 0.026 seconds

Application of New Load Management System Package for Development of the Optimal Electricity Consumption Strategy (최적의 부하소비전략 수립을 위한 새로운 부하관리시스템 패키지 응용에 관한 연구)

  • Chung, Koo-Hyung;Kim, Jin-Ho;Kim, Bal-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.602-605
    • /
    • 2003
  • This paper describes the consumer's decision-making process fur own optimal electricity consumption schedule and strategy using new load management system (LMS). As a result, it is demonstrated that a consumer in competitive electricity market has the opportunities to reduce electric payment by use of this LMS.

  • PDF

Development of Remote Load Management System Using PowerLine Communication (전력선 통신을 이용한 원격부하관리시스템 개발)

  • Na, Chae-Dong;Lee, Sung-Bum;Jeong, Eull-Gi
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.149-152
    • /
    • 2002
  • In this paper, an simple load management system was introduced. This system is composed of Main Controller, DTU(Dispersion Terminal Unit), Power Line Modem and HMI (Human Machine Interface) program. To control distant loads, network function using powerline communication is implemented in DTU, with HMI program, the untrained users are able to operate system easily. Additionally using the Powerline, the cost and time of installation is saved. The system performance was proved in a several experiments.

  • PDF

Xylem Sap Flow Affected by Short-term Variation of Soil Moisture Regimes at Higher Growth Period in 'Fuji'/M.9 Apple Trees with Different Fruit Loads (착과량 수준 및 생육성기 토양수분 함량 변화에 따른 '후지'/M.9 품종의 수액이동 특성)

  • Park, Jeong-Gwan;Kim, Seung-Heui;Lee, In-Bok;Park, Jin-Myeon
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.2
    • /
    • pp.164-169
    • /
    • 2006
  • This study was conducted for 10 days from 17 July to 26 July in 2005 to measure the amount of xylem sap flow under short-term variation of soil moisture regimes at -20 kPa, -50 kPa and -80 kPa in eight-year-old 'Fuji'/M.9 apple trees with different fruit loads. Fruit load was adjusted as three different treatments with standard (100%), 1/2 times (50%) and 2 times (200%) on the basis of optimum fruiting number per tree as the standard fruit load of Fuji cultivar. Trees with standard fruit load during the experimental period showed higher xylem sap flow at -50 kPa of soil moisture regimes than those of trees with 1/2 times and 2 times fruit load. Trees with 1/2 times and 2 times fruit load had similar patterns of the diurnal changes of xylem sap flow, vapor pressure deficit (VPD), and maximum evapotranspiration (ETm). However, trees with 2 times fruit load at -50 kPa and -80 kPa of soil moisture regimes produced lower amount of xylem sap flow than ETm. Trees with standard fruit load produced $1.06{\sim}3.93$ L/tree more amount of xylem sap flow than ETm at all soil moisture regimes. But xylem sap flow of tees with 2 times fruit load had 21% lower at -50 kPa and $31{\sim}36%$ lower at -20 kPa and -80 kPa of soil moisture regimes, respectively than that of trees with standard fruit load. Shoot growth and leaf area were significantly the highest in trees with standard fruit load while those of trees with 2 times fruit load recorded significantly lowest. Leaf water potential of trees with standard fruit load was lower than that of trees with 1/2 times and 2 times fruit load. It indicated that tees with standard fruit load had higher water use for transpiration than other treatments and tees with 2 times fruit load received more stress for the transpiration process under low soil moisture regimes. Consequently, 'Fuji'/M.9 apple trees, the fruit load and soil moisture should be maintained optimum to increase xylem sap flow and transpiration during higher growth period.

A Study on the On-Line Fuzzy ULTC Controller Design Based on Multiple Load Center Points (다중 부하중심점에 기반한 온라인 퍼지 ULTC 제어기 설계에 대한 연구)

  • Ko, Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.12
    • /
    • pp.514-521
    • /
    • 2006
  • The existing ULTC operation control strategy based on the measured data deteriorates the voltage compensation capability making the efficient corresponding to the load variation difficult by following the fixed load center point voltage. Accordingly, this paper proposes a new on-line fuzzy ULTC controller based on the designed multiple load center points which can improve the voltage compensation capability of ULTC and minimize voltage deviation by moving in real-time the load center point according to the load variation to an adequate position among the multiple load center points designed using the clustering technique. The Max-Min distance technique is adopted as the clustering technique for the decision of multiple load points from measured MTr load current and PTr voltage, and the minimum distance classifier is adopted for the decision of fuzzy output membership function. To verify the effectiveness of the proposed strategy, Visual C++ MFC-based simulation environments is developed. Finally, the superiority the proposed strategy is proved by comparing the fuzzy ULTC operation control results based on multiple load center points with the existing ULTC operation control results based on fixed load center point using the data for three day.

Real-time load monitoring system based mobile (무선 기반의 실시간 부하 모니터링 시스템)

  • Park, Hong-Jin
    • Journal of the Korea Computer Industry Society
    • /
    • v.5 no.9
    • /
    • pp.1095-1100
    • /
    • 2004
  • The computer system is gradually complicated because of explosive growth of computer system and IT technology. For efficient management of complicated system, system load monitoring technology is essential. In this paper, we is implemented the real-time load monitoring system based mobile than the traditional methods that are used load-related commands in system manager or specific load application programs based connected wire. Advantage of implemented load monitoring system in this paper is freely saw load information in time and space though mobile method like as PDA, cellular phone, more than traditional methods intime and space.

  • PDF

A Study on the Load Composition Rate Estimation Considering Reliability of Hourly Load Data and a Method for Enhancement of Data Quaility (시간별 부하자료의 신뢰도를 고려한 부하구성비 추정 및 데이터 품질 향상 방안에 관한 연구 -산업용 부하를 중심으로-)

  • Hwang Sung-Wook;Kim Jung-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.2
    • /
    • pp.67-69
    • /
    • 2006
  • A load composition rate estimation algorithm is developed for DSM evaluation system. The algorithm has the structure which is composed of data verification and development and can enhance the data quality Also a hourly weighting function is introduced for maintaining load shapes. The load composition rates of specific industrial customers are obtained and the results of case studies show that a reasonable load composition rate is achieved. Additionally qualify function deployment (QFD) is introduced to enhance quality and reliability of data.

Pattern Classification of Load Demand for Distribution Transformer (배전용 변압기 부하사용 패턴분류)

  • Yun, Sang-Yun;Kim, Jae-Chul;Lee, Young-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.89-91
    • /
    • 2001
  • This paper presents the result of pattern classification of load demand for distribution transformer in domestic. The field data of load demand is measured using the load acquisition device and the measurement data is used for the database system for load management of distribution transformed. For the pattern classification, the load data and the customer information data are also used. The K-MEAN method is used for the pattern classification algorithm. The result of pattern classification is used for the 2-step format of load demand curve.

  • PDF

Development of a Novel Load Capacity Estimation Method for Demand Factor Calculation of a Mail Center (우편집중국 수변전 설비 수용률 산정을 위한 새로운 부하 계산법 개발)

  • Yoon, Soon-Mann;Jeong, Jong-Chan;Kim, Kwang-Ho
    • Journal of Industrial Technology
    • /
    • v.30 no.A
    • /
    • pp.3-8
    • /
    • 2010
  • Recently, There have been many attempts to optimize energy usage in buildings and houses using Information Technology(IT) and the typical implementation can be found in Intelligent Building and Zero Energy Building. These kinds of buildings need to forecast the building loads, estimate the capacity requirement for power supply, and decide the capacity of the main transformer of the building. Currently, the capacity of the main transformer has been decided just using typical load estimation method not considering the load characteristics and patterns. In this paper, we propose a new load estimation method considering the load characteristics and patterns of the builiding. The proposed method was applied to actual mail center and verified the feasibility of application to actual design of buildings.

  • PDF