• Title/Summary/Keyword: Load frequency Control

Search Result 795, Processing Time 0.025 seconds

Control Strategy for Selective Compensation of Power Quality Problems through Three-Phase Four-Wire UPQC

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.576-582
    • /
    • 2011
  • This paper presents a novel control strategy for selective compensation of power quality (PQ) problems, depending upon the limited rating of voltage source inverters (VSIs), through a unified power quality conditioner (UPQC) in a three-phase four-wire distribution system. The UPQC is realized by the integration of series and shunt active power filters (APFs) sharing a common dc bus capacitor. The shunt APF is realized using a three-phase, four-leg voltage source inverter (VSI), while a three-leg VSI is employed for the series APF of the three-phase four-wire UPQC. The proposed control scheme for the shunt APF, decomposes the load current into harmonic components generated by consumer and distorted utility. In addition to this, the positive and negative sequence fundamental frequency active components, the reactive components and harmonic components of load currents are decomposed in synchronous reference frame (SRF). The control scheme of the shunt APF performs with priority based schemes, which respects the limited rating of the VSI. For voltage harmonic mitigation, a control scheme based on SRF theory is employed for the series APF of the UPQC. The performance of the proposed control scheme of the UPQC is validated through simulations using MATLAB software with its Simulink and Power System Block set toolboxes.

Seismic Analysis of the Main Control Boards for Nuclear Power Plant (원자력발전소의 Main Control Boards에 대한 내진 해석)

  • Byeon, Hoon-Seok;Lee, Joon-Keun;Kim, Jin-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.498-498
    • /
    • 2001
  • Seismic qualification of the Main Control Boards for nuclear power plants has been performed with the guideline of AS ME Section III. US NRC Reg. Guide and IEEE 344 code. The analysis model of the Main Control Boards is consist of beam. shell and mass element by using the finite element method. and, at the same time. the excitation forces and other operating loads for each model are encompassed with respect to different loading conditions. As the fundamental frequencies of the structure are found to be less than 33Hz. which is the upper frequency limit of the seismic load, the response spectrum analysis using ANSYS is performed in order to combine the modal stresses within the frequency limit. In order to confirm the structural and functional integrity of the major components, modal analysis theory is adopted to derive the required response spectrum at the component locations. As all the combined stresses obtained from the above procedures are less than allowable stresses and no mechanical or electrical failures are found from the seismic testing, it concludes the Main Control Boards is dynamically qualified for seismic conditions. Although the authors had confirmed the structural and functional integrity of both Main Control Boards and all the component, in this paper only the seismic analysis of the Main Control Board is introduced.

  • PDF

Passive shape control of force-induced harmonic lateral vibrations for laminated piezoelastic Bernoulli-Euler beams-theory and practical relevance

  • Schoeftner, J.;Irschik, H.
    • Smart Structures and Systems
    • /
    • v.7 no.5
    • /
    • pp.417-432
    • /
    • 2011
  • The present paper is devoted to vibration canceling and shape control of piezoelastic slender beams. Taking into account the presence of electric networks, an extended electromechanically coupled Bernoulli-Euler beam theory for passive piezoelectric composite structures is shortly introduced in the first part of our contribution. The second part of the paper deals with the concept of passive shape control of beams using shaped piezoelectric layers and tuned inductive networks. It is shown that an impedance matching and a shaping condition must be fulfilled in order to perfectly cancel vibrations due to an arbitrary harmonic load for a specific frequency. As a main result of the present paper, the correctness of the theory of passive shape control is demonstrated for a harmonically excited piezoelelastic cantilever by a finite element calculation based on one-dimensional Bernoulli-Euler beam elements, as well as by the commercial finite element code of ANSYS using three-dimensional solid elements. Finally, an outlook for the practical importance of the passive shape control concept is given: It is shown that harmonic vibrations of a beam with properly shaped layers according to the presented passive shape control theory, which are attached to an resistor-inductive circuit (RL-circuit), can be significantly reduced over a large frequency range compared to a beam with uniformly distributed piezoelectric layers.

Heavy-weight Impact Noise Reduction of Concrete Slab Reinforcement Using F.R.P (F.R.P 재료 보강에 의한 신개념 중량충격음 저감대책)

  • Jeong, Jeong-Ho;Yoo, Seung-Yup;Lee, Pyoung-Jik;Jeon, Jin-Yong;Jo, A-Hyoung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.383-386
    • /
    • 2005
  • Low frequency heavy-weight impact noise is the most irritating noise in Korean high-rise reinforced concrete apartment buildings. This low frequency noise is generated by foot traffic due to the fact that Koreans do not wear shoes at home. The transmission of the noise is facilitated by a load bearing wall structural system without beams and columns which is used in these buildings. In order to control low frequency heavy-weight impact noise, floating floors using isolation materials such as glass-wool mat and poly-urethane mat are used. However, it was difficult to control low frequency heavy-weight impact sound using isolation material. In this study, reinforcement of concrete slab using beams and plate was conducted. Using the FEM analysis, the effect of concrete slab reinforcement using FRP(fiber-glass reinforced plastic) on the bang machine impact vibration acceleration level and sound were conducted at the standard floor impact sound test building. The $3{\sim}4dB$ floor impact vibration acceleration level and impact sound pressure level were reduced and the natural frequency of slabs were changed.

  • PDF

A 360Hz DC Ripple-Voltage Suppression Scheme in Three-Phase Soft-Switched Buck Converter (360Hz DC 리플-전압 감소기법을 사용한 3-Phase Soft-Switched Buck Converter)

  • Choi, Ju-Yeop;Ko, Jong-Jin;Song, Joong-Ho;Choy, Ick;Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.12
    • /
    • pp.813-820
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output in three phase buck diode converter is presented in this paper. The proposed pulse frequency modulation methods and duty ratio modulation methods are employed to regulate the output voltage of the buck diode converter and guarantee zero-current-switching(ZCS) of the switch over the wide load range. The proposed control methods used in this paper provide generally good performance such as low THD of the input line current and unity power factor. In addition, control methods can be effectively used to suppress the low frequency ripple voltage appeared in the dc output voltage. The harmonic injection technique illustrates its validity and effectiveness through the simulations and experiments.

  • PDF

A Minimum Data-Rate Guaranteed Resource Allocation With Low Signaling Overhead in Multi-Cell OFDMA Systems

  • Kwon, Ho-Joong;Lee, Won-Ick;Lee, Byeong-Gi
    • Journal of Communications and Networks
    • /
    • v.11 no.1
    • /
    • pp.26-35
    • /
    • 2009
  • In this paper, we investigate how to do resource allocation to guarantee a minimum user data rate at low signaling overhead in multi-cell orthogonal frequency division multiple access (OFDMA) wireless systems. We devise dynamic resource allocation (DRA) algorithms that can minimize the QoS violation ratio (i.e., the ratio of the number of users who fail to get the requested data rate to the total number of users in the overall network). We assume an OFDMA system that allows dynamic control of frequency reuse factor (FRF) of each sub-carrier. The proposed DRA algorithms determine the FRFs of the sub-carriers and allocate them to the users adaptively based on inter-cell interference and load distribution. In order to reduce the signaling overhead, we adopt a hierarchical resource allocation architecture which divides the resource allocation decision into the inter-cell coordinator (ICC) and the base station (BS) levels. We limit the information available at the ICC only to the load of each cell, that is, the total number of sub-carriers required for supporting the data rate requirement of all the users. We then present the DRA with limited coordination (DRA-LC) algorithm where the ICC performs load-adaptive inter-cell resource allocation with the limited information while the BS performs intra-cell resource allocation with full information about its own cell. For performance comparison, we design a centralized algorithm called DRA with full coordination (DRA-FC). Simulation results reveal that the DRA-LC algorithm can perform close to the DRA-FC algorithm at very low signaling overhead. In addition, it turns out to improve the QoS performance of the cell-boundary users, and achieve a better fairness among neighboring cells under non-uniform load distribution.

Design of Neuro-Fuzzy Controller for Load Frequency Control of Power Line (계통의 부하주파수 제어를 위한 뉴로-퍼지제어기 설계에 관한 연구)

  • Lee, Oh-Keol;Kim, Sang-Hyo
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2005.11a
    • /
    • pp.373-376
    • /
    • 2005
  • 본 논문에서는 이와 같은 요청에 부합되는 강인한 처지제어기를 얻고자, 다층 신경회로망을 이용하여 퍼지제어기 멤버쉽 함수의 전건부 및 후건부 파라미터들을 시스템에 알맞게 자기 조정하기 위해 최급구배법(Steepest Gradient Method)에 근거한 오차 역전파 알고리즘으로 적응 학습시킬 수 있는 뉴로-퍼지제어기 (Neuro-Fuzzy Control : NFC)의 구조 및 알고리즘을 제안하였다.

  • PDF

The optimal efficiency drives of 3-phase induction motor by VV-VF control (VV-VF 제어에 의한 3상유도전동기의 고효율화 운전에 관한 연구)

  • 박민호;설승기
    • 전기의세계
    • /
    • v.30 no.7
    • /
    • pp.454-459
    • /
    • 1981
  • The aim of study in this paper is that in a system drive of the converter-inverter fed induction motor, the minimum input power can be maintained by control the voltage and frequency of the motor. In theoretical and experiment results describtion motor efficiency is improved by properly varying the ratio v/f. At lightly load condition, for example its efficiency was improved from 44% to 66% as the ratio of v/f varied from 1 to 0.57.

  • PDF

LFC Considering the Changing Rate of Governor Speed (조속기 입력의 변화율을 고려한 최적주파수 제어)

  • 박영문;유찬수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.3
    • /
    • pp.100-105
    • /
    • 1984
  • The optimal Load-Frequency Control law is presented with the performance criterion which includes the changing rate of governor speed. The authors propose two controllers. One is a dynamic controller using the method of state augmentation and the other is a constant gain controller with use of the trace function lemma by Kleinman. For a more practical realization, a reduced-order Luenberger observer is applied in order to identify unmeasurable states and power demand. The control schemees presented here are tested through the model developed by Elgerd, and the usefulness is demonstrated.

  • PDF

Development of Operation and Control Technology of Energy Storage System for Frequency Regulation and Operation by Grid Connected Automatic Control (주파수조정용 에너지저장장치 운전제어 기술의 개발과 계통연계 자동제어 운전)

  • Lim, Geon-Pyo;Choi, Yo-Han;Im, Ji-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.235-241
    • /
    • 2016
  • Grid-connected, large-capacity energy storage systems (ESS) can be used for peak load supply, frequency regulation, and renewable energy output smoothing. In order to confirm the capability of battery ESS to provide such services, 4MW/ 8MWh battery ESS demonstration facility was built in the Jocheon substation on Jeju Island. The frequency regulation technology developed for the Jocheon demonstration facility then became the basis for the 28MW and 24MW frequency regulation ESS facilities installed in 2014 at the Seo-Anseong and Shin-Yongin substations, respectively. The operation control systems at these two facilities were continuously improved, and their successful commercialization led to the construction of additional ESS facilities all over Korea in 2015. In seven (7) locations nationwide (e.g., Shin-Gimje and Shin-Gyeryeong), a total of 184 MW of ESS had been commercialized in 2016. The trial run for the new ESS facilities had been completed between April and May in 2016. In this paper, results of the trial run from each of the ESS facilities are presented. The results obtained from the Seo-Anseong and Shin-Yongin substations during a transient event by a nuclear power plant trip are also presented in this paper. The results show that the frequency regulation battery ESS facilities were able to quickly respond to the transient event and trial run of ESS is necessary before it is commercialized.