• Title/Summary/Keyword: Load frequency Control

Search Result 795, Processing Time 0.036 seconds

Comparative Analysis for the Frequency Estimation Algorithms (주파수 변화 추정 알고리즘 비교분석)

  • Kim, Chul-Hun;Kang, Sang-Hee;Nam, Soon-Ryul;Kim, Su-Whoan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2199-2200
    • /
    • 2006
  • Reliable frequency estimation is important for active power control, load shedding and generator protection. Thereby, frequency estimation is researched and some algorithms is proposed. This paper analyzed strength and weakness of each algorithms through comparative analysis of frequency estimation. Used algorithms are Zero Crossing detection, Discrete Fourier Transformation, Least Error Squares.

  • PDF

Comparative Analysis for the Frequency Estimation Algorithms (주파수 변화 추정 알고리즘 비교분석)

  • Kim, Chul-Hun;Kang, Sang-Hee;Nam, Soon-Ryul;Kim, Su-Whoan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.567-568
    • /
    • 2006
  • Reliable frequency estimation is important for active power control, load shedding and generator protection. Thereby, frequency estimation is researched and some algorithms is proposed. This paper analyzed strength and weakness of each algorithms through comparative analysis of frequency estimation. Used algorithms are Zero Crossing detection, Discrete Fourier Transformation, Least Error Squares.

  • PDF

Comparative Analysis for the Frequency Estimation Algorithms (주파수 변화 추정 알고리즘 비교분석)

  • Kim, Chul-Hun;Kang, Sang-Hee;Nam, Soon-Ryul;Kim, Su-Whoan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1233-1234
    • /
    • 2006
  • Reliable frequency estimation is important for active power control, load shedding and generator protection. Thereby, frequency estimation is researched and some algorithms is proposed. This paper analyzed strength and weakness of each algorithms through comparative analysis of frequency estimation. Used algorithms are Zero Crossing detection, Discrete Fourier Transformation, Least Error Squares.

  • PDF

Comparative Analysis for the Frequency Estimation Algorithms (주파수 변화 추정 알고리즘 비교분석)

  • Kim, Chul-Hun;Kang, Sang-Hee;Nam, Soon-Ryul;Kim, Su-Whoan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1693-1694
    • /
    • 2006
  • Reliable frequency estimation is important for active power control, load shedding and generator protection. Thereby, frequency estimation is researched and some algorithms is proposed. This paper analyzed strength and weakness of each algorithms through comparative analysis of frequency estimation. Used algorithms are Zero Crossing detection, Discrete Fourier Transformation, Least Error Squares.

  • PDF

Shape Design of the NFR Suspension Load Beam Considering Dynamic Characteristics (NFR 서스펜션의 동특성을 고려한 형상설계에 관한 연구)

  • Eun Gilsoo;Kim Nohyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.376.2-376
    • /
    • 2002
  • In this study, the shape of suspension load beam for NFR(Near Field Recording) was proposed, which was designed using Topology optimization based on Homogenization method. Lens and Micro-mirror are attached to the end of the suspension load beam for collection and control the light, which increasing the system mass. Increment of the system mass cause to decrease the tracking stiffness mode frequency. (omitted)

  • PDF

Vector Control of PM Motor without any Rotational Transducer PART 1 - Surface Mounted Permanent Magnet Motor (위치 검출기가 없는 영구자석 동기 전동기의 제어 PART1 - 표면부착형 영구자석 전동기)

  • Jang, Ji-Hun;Ha, Jeong-Ik;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.9
    • /
    • pp.453-458
    • /
    • 2001
  • This paper presents a new vector control algorithm of the surface mounted permanent magnet motor (SMPMM) without any rotational tranceducer. Originally, SMPMM does not have any magnetic saliency in structure, but it has a little magnetic saliency due to the saturation by the flux of the permanent magnet. Moreover, it varies according to the load conditions and the control performance of schematics using the saliency can be easily degraded. To prevent it and to improve the performance of the proposed algorithm, the saliency of a SMPMM under various load conditions is analyzed. In the proposed algorithm, the saliency or the impedance difference related to the saliency is utilized in order to estimate the position and speed of the rotor. And the high frequency signal is injected into the motor to measure the impedance difference and also to enhance the control performance of the system. The experimental results verify the performance of the proposed sensorless algorithm.

  • PDF

A Current-Fed Parallel Resonant Push-Pull Inverter with a New Cascaded Coil Flux Control for Induction Heating Applications

  • Namadmalan, Alireza;Moghani, Javad Shokrollahi;Milimonfare, Jafar
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.632-638
    • /
    • 2011
  • This paper presents a cascaded coil flux control based on a Current Source Parallel Resonant Push-Pull Inverter (CSPRPI) for Induction Heating (IH) applications. The most important problems associated with current source parallel resonant inverters are start-up problems and the variable response of IH systems under load variations. This paper proposes a simple cascaded control method to increase an IH system's robustness to load variations. The proposed IH has been analyzed in both the steady state and the transient state. Based on this method, the resonant frequency is tracked using Phase Locked Loop (PLL) circuits using a Multiplier Phase Detector (MPD) to achieve ZVS under the transient condition. A laboratory prototype was built with an operating frequency of 57-59 kHz and a rated power of 300 W. Simulation and experimental results verify the validity of the proposed power control method and the PLL dynamics.

Modeling and Control of Integrated STATCOM-SMES System to Improve Power System Oscillations Damping

  • Molina, Marcelo G.;Mercado, Pedro E.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.528-537
    • /
    • 2008
  • Primary frequency control(PFC) has the ability to regulate short period random variations of frequency during normal operation conditions and also to respond rapidly to emergencies. However, during the past decade, numerous significant sized blackouts occurred worldwide that resulted in serious economic losses. Therefore, the conclusion has been reached that the ability of the current PFC to meet an emergency is poor, and security of power systems should be improved. An alternative to enhance the PFC and thus security is to store excessive amounts of energy during off-peak load periods in efficient energy storage systems for substituting the primary control reserve. In this sense, superconducting magnetic energy storage(SMES) in combination with a static synchronous compensator(STATCOM) is capable of supplying power systems with both active and reactive powers simultaneously and very rapidly, and thus is able to enhance the security dramatically. In this paper, a new concept of PFC based on incorporating a STATCOM-SMES is presented. A complete detailed model is proposed and a new control scheme is designed, comprising an enhanced frequency control scheme, and a fully decoupled current control strategy in d-q coordinates with a novel controller to prevent dc bus capacitors voltage drift/imbalance. The performance of the proposed control schemes is validated through digital simulation carried out using MATLAB/Simulink.

A Seamless Transfer Algorithm Based on Frequency Detection with Feedforward Control Method in Distributed Generation System

  • Kim, Kiryong;Shin, Dongsul;Lee, Jaecheol;Lee, Jong-Pil;Yoo, Dong-Wook;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1066-1073
    • /
    • 2015
  • This paper proposes a control strategy based on the frequency detection method, comprising a current control and a feed-forward voltage control loop, is proposed for grid-interactive power conditioning systems (PCS). For continuous provision of power to critical loads, PCS should be able to check grid outages instantaneously. Hence, proposed in the present paper are a frequency detection method for detecting abnormal grid conditions and a controller, which consists of a current controller and a feedforward voltage controller, for different operation modes. The frequency detection method can detect abnormal grid conditions accurately and quickly. The controller which has current and voltage control loops rapidly helps in load voltage regulation when grid fault occurs by changing reference and control modes. The proposed seamless transfer control strategy is confirmed by experimental results.

Robust Digital Fuzzy Controller Design for Load-Frequency Control of Nonlinear Power System (비선형 전력계통 시스템의 부하주파수 제어를 위한 강인한 디지탈 퍼지 제어기의 설계)

  • Jeon, Sang-Won;Joo, Young-Hoon;Lee, Ho-Jae;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.110-112
    • /
    • 2000
  • A new robust digital fuzzy controller design methodology is proposed for load frequency of nonlinear power system with valve position limits of governor in the presence of parametric uncertainties. The Takagi-Sugeno (TS) fuzzy model is adopted for fuzzy modeling of the nonlinear power system. A sufficient condition of robust stability for robust fuzzy control with parametric uncertainties is presented in the sense of Lyapunov. The controller that designed by preposed robust fuzzy controller design method is based compounding condition between continues system and discrete system. The effectiveness of controller that designed by the proposed robust fuzzy controller design method is demonstrated through simulation example.

  • PDF