• Title/Summary/Keyword: Load flow analysis

Search Result 876, Processing Time 0.038 seconds

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2008 (설비공학 분야의 최근 연구 동향: 2008년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.715-732
    • /
    • 2009
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2008. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends in thermal and fluid engineering have been surveyed in the categories of general fluid flow, fluid machinery and piping, new and renewable energy, and fire. Well-developed CFD technologies were widely applied in developing facilities and their systems. New research topics include fire, fuel cell, and solar energy. Research was mainly focused on flow distribution and optimization in the fields of fluid machinery and piping. Topics related to the development of fans and compressors had been popular, but were no longer investigated widely. Research papers on micro heat exchangers using nanofluids and micro pumps were also not presented during this period. There were some studies on thermal reliability and performance in the fields of new and renewable energy. Numerical simulations of smoke ventilation and the spread of fire were the main topics in the field of fire. (2) Research works on heat transfer presented in 2008 have been reviewed in the categories of heat transfer characteristics, industrial heat exchangers, and ground heat exchangers. Research on heat transfer characteristics included thermal transport in cryogenic vessels, dish solar collectors, radiative thermal reflectors, variable conductance heat pipes, and flow condensation and evaporation of refrigerants. In the area of industrial heat exchangers, examined are research on micro-channel plate heat exchangers, liquid cooled cold plates, fin-tube heat exchangers, and frost behavior of heat exchanger fins. Measurements on ground thermal conductivity and on the thermal diffusion characteristics of ground heat exchangers were reported. (3) In the field of refrigeration, many studies were presented on simultaneous heating and cooling heat pump systems. Switching between various operation modes and optimizing the refrigerant charge were considered in this research. Studies of heat pump systems using unutilized energy sources such as sewage water and river water were reported. Evaporative cooling was studied both theoretically and experimentally as a potential alternative to the conventional methods. (4) Research papers on building facilities have been reviewed and divided into studies on heat and cold sources, air conditioning and air cleaning, ventilation, automatic control of heat sources with piping systems, and sound reduction in hydraulic turbine dynamo rooms. In particular, considered were efficient and effective uses of energy resulting in reduced environmental pollution and operating costs. (5) In the field of building environments, many studies focused on health and comfort. Ventilation. system performance was considered to be important in improving indoor air conditions. Due to high oil prices, various tests were planned to examine building energy consumption and to cut life cycle costs.

Evaluation of Eutrophication and Control Alternatives in Sejong Weir using EFDC Model (EFDC 모델에 의한 세종보의 부영양화 및 제어대책 평가)

  • Yun, Yeojeong;Jang, Eunji;Park, Hyung-Seok;Chung, Se-Woong
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.548-561
    • /
    • 2018
  • The objectives of this study were to construct a three-dimensional (3D) hydrodynamic and water quality model (EFDC) for the river reach between the Daecheong dam and the Sejong weir, which are directly affected by Gap and Miho streams located in the middle of the Geum River, and to evaluate the trophic status and water quality improvement effect according to the flow control and pollutant load reduction scenarios. The EFDC model was calibrated with the field data including waterlevel, temperature and water quality collected from September, 2012 to April, 2013. The model showed a good agreement with the field data and adequately replicated the spatial and temporal variations of water surface elevation, temperature and water quality. Especially, it was confirmed that spatial distributions of nutrients and algae biomass have wide variation of transverse direction. Also, from the analysis of algal growth limiting factor, it was found that phosphorous loadings from Gap and Miho streams to Sejong weir induce eutrophication and algal bloom. The scenario of pollutant load reduction from Gap and Miho streams showed a significant effect on the improvement of water quality; 4.7~18.2% for Chl-a, 5.4~21.9% for TP at Cheongwon-1 site, and 4.2~ 17.3% for Chl-a and 4.7~19.4% for TP at Yeongi site. In addition, the eutrophication index value, identifying the tropic status of the river, was improved. Meanwhile, flow control of Daecheong Dam and Sejong weir showed little effect on the improvement of water quality; 1.5~2.4% for Chl-a, 2.5~ 3.8% for TP at Cheongwon-1 site, and 1.2~2.1% for Chl-a and 0.9~1.5% for TP at Yeongi site. Therefore, improvement of the water quality in Gap and Miho streams is essential and a prerequirement to meet the target water quality level of the study area.

Estimation of Flows and Pollutant Loads from GIS Analysis using Cell-based Geospatial and Georgraphic Information Data (격자기반의 지형 및 지리정보자료와 GIS분석기법을 이용한 유역의 유출량 및 오염부하량 추정)

  • Cho, Jae-Myoung;Lee, Mi-Ran;Yun, Hong-Sik
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.4
    • /
    • pp.381-392
    • /
    • 2011
  • Pollutant loads calculated with unit factor method can not identity seasonal variations of pollutant inputs. Estimation of pollutant loads considering rainfall runoff can overcome these limits. SCS curve number method was applied to estimate runoff of each event of Koeup watershed of Koheung estuary lake. SCS curve numbers were calculated based upon land use, soil types of the catchment using GIS. Point and nonpoint source pollutant loads were summed up for total loads estimation. Those from nonpoint source were estimated by multiplying the calculated runoff and expected mean concentrations (EMC) presented by the Minister of Environment of Korea. DEM can present three dimensional views of a terrain, identity stream networks and flow accumulation. Furthermore, it can examine accumulated pollutant loads of specific point of a catchment. Therefore, cell based pollutant load estimation was attempted using DEM. ArcView was utilized to collect, store and manipulate spatial and attribute data of pollutant sources and features of the catchment. Cell-based DEM which was established by the GRID module of ARC/INFO was employed to estimate flows and pollutant loads.

Prediction of Continuous Discharge and Water Quality Change for Gate Operation in Seonakdong River Experimental Catchment Using SWAT (서낙동강 시험유역에서의 SWAT 모형을 이용한 수문 운영에 따른 연속유출 및 수질변화 예측)

  • Kang, Deok-Ho;Kim, Jung-Min;Kim, Tae-Won;Kim, Young-Do
    • Journal of Wetlands Research
    • /
    • v.14 no.1
    • /
    • pp.21-33
    • /
    • 2012
  • The dominant land use at the Seonakdong river watershed is paddy and forest areas and the Seonakdong river stands still. Thus, the water pollution in the Seonakdong river is becoming more serious for the non-point source. In this study, SWAT(Soil and Water Assessment Tool) model was evaluated for simulation of flow and water quality behaviors in Seonakdong river. To perform the calibration and verification of the SWAT model, the measurements of discharge and water quality were performed for the period from 2006 to 2007 at 5 gauging stations in Seonakdong river. The $R^2$ value for discharge and water quality were 0.86 and 0.70 respectively for calibration after the sensitive analysis. The $R^2$ value for discharge and water quality were 0.81 and 0.51 respectively for verification. The simulation results show that BOD value in the river tends to decrease after the opening of gates and the patterns of TN and TP concentrations are similar as that of BOD. The gate operators need to determine how to supply water in drought season for effective water quality improvement. This study shows that the SWAT model, which is capable of simulating hydrologic and water quality behaviors temporarily and spatially at watershed scale, could be used to get the gate operation rule for the water quality management in Seonakdong river.

Comparative Analysis of QUAL2E, QUAL2K and CAP Steady State Water Quality Modeling Results in Downstream Areas of the Geum River, Korea (QUAL2E, QUAL2K 및 CAP 모델을 이용한 금강 하류 하천구간 정상상태 수질모델링 결과 비교 분석)

  • Seo, Dongil;Yun, Jong Uk;Lee, Jae Woon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.121-129
    • /
    • 2008
  • Major factors affecting water quality in rivers are transportation, input of pollutant loads and kinetic transformation of pollutants. Government level decision makings on water quality management are based on steady state water quality modeling. However, it is more than often that such a steady state assumption is far from real situations in rivers. Therefore, it is unavoidable to have modeling errors in water quality modeling especially for steady state modeling for longer period of time. Authors attempted to identify sources of errors in results of steady state models and thus tried to find out ways to minimize those errors. Three water quality models, QUAL2E (Brown et al., 1983), QUAL2K (Chapra et al., 2006) and CAP (Seo and Lee, 2000) were applied to the lower stream of the Geum River. $BOD_5$ and COD tend to underestimate observed data while TN and TP showed relatively smaller errors. QUAL2E model provided best calibration results for BOD5 and TP and QUAL2K model showed best calibration results for TN. Since these errors are only relative values, it was difficult to conclude which model is better performing in certain situations. The most probable reasons for errors in water quality modeling are; 1) inappropriate consideration on flow characteristics, 2) lack of information on incoming pollutant load and 3) inappropriate location of sampling for water quality analysis.

CO2 Emission Structure Analysis of Industrial Sector with Environmental Input-Output Table 2005 (환경산업연관표 2005를 이용한 산업부문의 이산화탄소(CO2) 배출 분석)

  • Kim, Yoon Kyung
    • Environmental and Resource Economics Review
    • /
    • v.20 no.1
    • /
    • pp.1-31
    • /
    • 2011
  • By employing Environmental Input-Output Table 2005, which has 76 intermediate sector and 21 energy sources, this paper analyses the flow of energy demand and $CO_2$ after estimating an induced $CO_2$ emissions from 76 industrial sectors. Index of $CO_2$ intensity($CO_2/GDP$) and other index of $CO_2$ intensity($CO_2/calory$) showed that final demand sector uses more high calory energy source. Intermediate sector used less environmental friendly energy source and emit more $CO_2$ at same calory. Industries those has high induced $CO_2$ emissions are Thermal Power($32.587CO_2-g/Won$), Cement($10.370CO_2-g/Won$), Road Transportation($7.255CO_2-g/Won$), Cokes and Other Coal Products($5.791CO_2-g/Won$), Steam and Hot water supply, Sewage, Sanitary services($4.575CO_2-g/Won$). It is shown that industry such as Iron and Steel which has low $CO_2$ intensity, high backward linkage effect and high forward linkage effect makes high induced $CO_2$ emissions. Environmental load and $CO_2$ emissions in overall economy will decrease when not high $CO_2$ intensity industry but also low $CO_2$ intensity industry makes lower $CO_2$ intensity.

  • PDF

Study on the Application of V2G for Electric Vehicles in Korea Using Total Cost of Ownership Analysis (총소유비용 분석을 이용한 전기차의 V2G 도입에 대한 연구)

  • Kim, Younghwan;Lee, Jae-Seung
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.129-143
    • /
    • 2015
  • Increasing concerns on climate change and energy security accelerated policies to reduce green-house gas emission, especially from the transportation sector. Electric vehicle (EV) has been on the spotlight to deal with such environmental issue and V2G (Vehicle-to-Grid) technology began to draw attentions as an alternative to reduce ownership costs while contributing to an efficient and decentralized power grid. This study conducts a scenario analysis on total cost of ownership of EV under V2G scheme and compare with non-V2G EV and Internal Combustion Engine (ICE) vehicle. As result, V2G service is expected to provide an annual average profit of $210 to EV users willing to reverse flow its residual power in the battery. The profit from V2G service leaves a margin of $4,530 over operational lifetime, compared with $2,420 cost of charge for non-V2G EV. In summary, total cost of ownership of V2G-capable EV was 6.2% less than non-V2G EV and 10.2% higher than ICE vehicle. The results confirm a comparative economic advantage of operating EV under V2G scheme. Increased number of EVs with V2G service has shown to provide positive effects to power industry for valley filling in load distribution, thus, favorably increasing the overall economic feasibility.

Fire Resistance Performance of High Strength Concrete with 4 Deformation Factors (4변형 인자에 의한 고강도콘크리트의 내화성능 평가)

  • Lee, Tae Gyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.5
    • /
    • pp.112-120
    • /
    • 2012
  • A numerical model considering the internal vaporization and the creep effect, in the form of a analytical program, for tracing the behavior of high strength concrete(HSC) members exposed to fire is presented. The two stages, i.e., spalling procedure and fire resistance time, associated with the thermal, moisture flow, creep and structural analysis, for the prediction of fire resistance behavior are explained. The use of the analytical program for tracing the response of HSC member from the initial pre-loading stage to collapse, due to fire, is demonstrated. Moisture evaporates, when concrete is exposed to fire, not only at concrete surface but also at inside the concrete to adjust the equilibrium and transfer properties of moisture. Finite element method is employed to facilitate the moisture diffusion analysis for any position of member, so that the prediction method of the moisture distribution inside the concrete members at fire is developed. The validity of the numerical model used in this program is established by comparing the predictions from this program with results from others fire resistance tests. The analytical program can be used to predict the fire resistance of HSC members for any value of the significant parameters, such as load, sectional dimensions, member length, and concrete strength.

p-Version Finite Element Analysis of Composite Laminated Plates with Geometric and Material Nonlinearities (기하 및 재료비선형을 갖는 적층평판의 p-Version 유한요소해석)

  • 홍종현;박진환;우광성
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.3
    • /
    • pp.491-499
    • /
    • 2002
  • A p-version finite element model based on degenerate shell element is proposed tot the analysis of orthotropic laminated plates. In the nonlinear formulation of the model, the total Lagrangian formulation is adopted with large deflection and moderate rotation being accounted tot in the sense of yon Karman hypothesis. The material model is based on the Huber-Mises yield criterion and Prandtl-Reuss flow rule in accordance with the theory of strain hardening yield function, which is generalized lot anisotropic materials by introducing the parameters of anisotropy. The model is also based on extension of equivalent-single layer laminate theory(ESL theory) with shear deformation, leading to continuous shear strain at the interface of two layers. The integrals of Legendre polynomials are used for shape functions with p-level varying from 1 to 10. Gauss-Lobatto numerical quadrature is used to calculate the stresses at the nodal points instead of Gauss points. The validity of the proposed P-version finite element model is demonstrated through several comparative points of iew in terms of ultimate load, convergence characteristics, nonlinear effect, and shape of plastic tone.

A Study for the Adaptation of Simulation of Uniaxial Compressive Strength Test for Concrete in 3-Dimensional Particle Bonded Model (3차원 입자 결합 모델에서 콘크리트의 일축압축실험 모사 적용성 연구)

  • Lee, Hee-Kwang;Jeon, Seok-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.147-156
    • /
    • 2008
  • In an uniaxial compressive test of a concrete standard specimen (150$\times$300 mm) the crack initiation and extension with the stress increase are the major reason of the failure, which is similar to the breakage of the particle bonding in the simulation by using particle bonded model, especially particle flow code in 3 dimensions (PFC3D) developed by Itasca Consulting Group Inc. That is the main motive to study the possibility of an uniaxial compressive strength test simulation. It is important to investigate the relationship between the micro-parameters and the macro-properties because the 3-dimensional particle bonded model uses the spherical particles to analyze the physical phenomena. Contact bonded model used herein has eight micro-parameters and there are five macro-properties; Young's modulus, Poisson's ratio, uniaxial compressive strength and the crack initiation stress and the ratio concerning the crack propagation with the stress. To simulate the compressive test we made quantitative relationships between the micro-parameters and the macro-properties by using the fractional factorial design and various sensitivity analyses including regression analysis, which result in the good agreement with the previous studies. Also, the stress-stain curve and the crack distribution over the specimen given by PFC3D showed the mechanical behavior of the concrete standard specimen under the uniaxial compression. It is concluded that the particle bonded model can be a good tool for the analyzing the mechanical behavior of concrete under the uniaxial compressive load.