• Title/Summary/Keyword: Load current control

Search Result 1,281, Processing Time 0.029 seconds

Modeling and Analysis of SEIG-STATCOM Systems Based on the Magnitude-Phase Dynamic Method

  • Wang, Haifeng;Wu, Xinzhen;You, Rui;Li, Jia
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.944-953
    • /
    • 2018
  • This paper proposes an analysis method based on the magnitude-phase dynamic theory for isolated power systems with static synchronous compensators (STATCOMs). The stability margin of an isolated power system is greatly reduced when a load is connected, due to the disadvantageous features of the self-excited induction generators (SEIGs). To analyze the control process for system stability and to grasp the dynamic characteristics in different timescales, the relationships between the active/reactive components and the phase/magnitude of the STATCOM output voltage are derived in the natural reference frame based on the magnitude/phase dynamic theory. Then STATCOM equivalent mechanical models in both the voltage time scale and the current time scale are built. The proportional coefficients and the integral coefficients of the control process are converted into damping coefficients, inertia coefficients and stiffness coefficients so that analyzing its controls, dynamic response characteristics as well as impacts on the system operations are easier. The effectiveness of the proposed analysis method is verified by simulation and experimental results.

Static Performance Diagnosis Based on Pressure Signal for a Flow Control Servovalve or Proportional Direction Valve (유량제어용 서보밸브와 비례방향밸브의 압력신호를 이용한 정적 성능 진단에 관한 연구)

  • Kim, S.D.;Jeon, S.H.;Kim, I.D.;Ham, Y.B.
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.32-41
    • /
    • 2012
  • Most diagnosis methods for servo valves requires installing spool displacement sensor or flow sensor as well as pressure sensor. The measurement of flow is hard to implement and many kinds of servovalves or proportional direction valves do not have a built-in spool displacement sensor. In this study, static performances of servovalve or proportional-direction-valve are studied theoretically and a diagnosis technique, which uses only load pressure and input current signal, is assessed. An experimental setup was made based upon a personal computer and the LabVIEW graphical language. A series of diagnosis tests were performed and the analysis results showed it possible to measure the pressure gain, hysteresis and null bias in a relatively simple methodology.

The Application and Verification of the 2MVA Battery Energy Storage System(BESS) with Wind-turbine in Micro-grid of Gapado, Jeju (가파도 마이크로그리드에서의 풍력발전 연계를 위한 2MVA급 배터리 에너지 저장시스템(BESS) 적용 및 실증)

  • Kim, Seung-Mo;Oh, Seung-Jin;Lee, Jong-Hak;Kim, Tae-Hyeong;Kwon, Byung-Ki;Ahn, Jae-Min;Jin, Kyung-Min;Choi, Chang-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.303-311
    • /
    • 2014
  • This paper shows the test result of 2MVA BESS(Battery Energy Storage System) with wind-turbine in micro-grid of the Gapado. To implement of micro-grid with BESS, characteristics of generator and customer load in grid are considered. Also, to operate of 2-parallel PCU(Power Conversion Unit) in BESS, the droop control is adopted with operating mode of grid independent. Performances of BESS with wind-turbine were verified by analysis of power quality such as voltage harmonics, ratio of voltage and frequency regulation, and by measurement of waveform such as output voltage and current.

Design of the Two-Stage DC-DC Converter for 1kW Fuel Cell Power Generation System (1kW급 연료전지 발전용 2단 구성 방식의 DC-DC 컨버터 설계)

  • Yoo, Ho-Won;Jung, Yong-Min;Lim, Seung-Beom;Lee, Jun-Young;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.206-208
    • /
    • 2008
  • In this paper, the two-stage DC-DC converter is proposed to make the control simple and to boost the low input voltage in the fuel cell generating system. The low efficiency of the conventional power converter is caused by a characteristic of the low-voltage and high-current in the fuel cell generating system. High-frequency transformer is needed to block the noise and to guarantee the safety of cell and load as a magnetically insulation. The proposed two-stage DC-DC converter for a fuel cell generation is more efficient than the traditional one-stage converter and easy to control. The design of a high-frequency transformer is also simple. Finally, the utility of the proposed converter is proved by the simulations and experiments.

  • PDF

Study on the Air Bearings with Actively Controllable Magnetic Preloads for an Ultra-precision Linear Stage (초정밀 직선 이송계용 능동 자기예압 공기베어링에 관한 연구)

  • Ro, Seung-Kook;Kim, Soo-Hyun;Kwak, Yoon-Keun;Park, Chun-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.6
    • /
    • pp.134-142
    • /
    • 2008
  • In this paper, we propose a precise linear motion stage supported by magnetically preloaded air bearings. The eight aerostatic bearings with rectangular carbon porous pads were located only one side of vertical direction under the platen where four bearings are in both sides of horizontal direction as wrap-around-design, and this gives simpler configuration than which constrained by air bearings for all direction. Each of the magnetic actuators has a permanent magnet generating static magnetic flux far required preload and a coil to perturb the magnetic farce resulting adjustment of air- bearing clearance. The characteristics of porous aerostatic bearing are analyzed by numerical analysis, and analytic magnetic circuit model is driven for magnetic actuator to calculate preload and variation of force due to current. A 1-axis linear stage motorized with a coreless linear motor and a linear encoder was designed and built to verify this design concept. The load capacity, stiffness and preload force were examined and compared with analysis. With the active magnetic preloading actuators controlled with DSP board and PWM power amplifiers, the active on-line adjusting tests about the vertical, pitching and rolling motion were performed. It was shown that motion control far three DOF motions were linear and independent after calibration of the control gains.

Sensorless Speed Control of Direct Current Motor by Neural Network (신경회로망을 이용한 직류전동기의 센서리스 속도제어)

  • 강성주;오세진;김종수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.90-97
    • /
    • 2004
  • DC motor requires a rotor speed sensor for accurate speed control. The speed sensors such as resolvers and encoders are used as speed detectors. but they increase cost and size of the motor and restrict the industrial drive applications. So in these days. many Papers have reported on the sensorless operation or DC motor(3)-(5). This paper Presents a new sensorless strategy using neural networks(6)-(8). Neural network structure has three layers which are input layer. hidden layer and output layer. The optimal neural network structure was tracked down by trial and error and it was found that 4-16-1 neural network has given suitable results for the instantaneous rotor speed. Also. learning method is very important in neural network. Supervised learning methods(8) are typically used to train the neural network for learning the input/output pattern presented. The back-propagation technique adjusts the neural network weights during training. The rotor speed is gained by weights and four inputs to the neural network. The experimental results were found satisfactory in both the independency on machine parameters and the insensitivity to the load condition.

Development of Tie-Bar Installation Method for Concrete Pavement Widening (콘크리트포장 확장부 타이바 설치방법의 개발)

  • Hwang In-Kyu;Yang Sung-Chul;Jeong Jin-Hoon;Yoo Tae-Seok
    • International Journal of Highway Engineering
    • /
    • v.8 no.1 s.27
    • /
    • pp.33-43
    • /
    • 2006
  • Pull-out strength of tie-bin used in pavement construction is not an issue because those are embedded in newly placed concrete slabs. However, sufficient pull-out strength should be secured in widening constructions because, in case, the tie-bars are inserted into drilled holes of the existing slabs with liquid filler. Insufficient pull-out strength will result in lowered load transfer efficiency between adjacent slabs in addition to poor serviceability and durability due to joint widening. The pull-out strength of the tie-bars installed by current method is evaluated and improved methods are proposed. The field pull-out strength obtained by the current method was only 42.7% of required strength. Its first counterproposal is using to insert the liquid filler into drilled holes and stoppers to prevent it from flowing out of the holes. However, this method was not judged to secure desired level of quality control. The second counterproposal which substitutes the existing type of the tie-bars by SL anchor bolts was judged to secure sufficient pull out-strength in addition to the quality control and constructibility.

  • PDF

Treatment Stimulator's Pulse of Transcranial Magnetic Stimulation (경두개 자기자극장치의 치료자극 펄스)

  • Kim, Whi-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.289-296
    • /
    • 2009
  • In this study, I presented power control unit with potential use in the magnetic stimulation of biological systems. The effect of the magnetic stimulation depends on the geometry and orientation of the induced electric field as well as on the current pulse waveform delivered by the stimulator coil. TMS is achieved from the outside of the head using pulses of electromagnetic field that induce an electric field in the brain. There are numerous possibities in the applications TMS, such as diagnosis and therapy through the brain stimulation. These factors are very important to define the equipment requirements and characteristics in that the topology of the power supply and the size and geometry of the coil. The proposed solution is the generation of current pulses with variable amplitude and duration, according to a user defined input. Another solution is the topology that uses elements to store and transfer energy from the power source to the load. In addition to proposed topology, an adequate control strategy and right set of the power circuit parameters made possible to obtain unipolar waves and bipolar waves.

Firing Angle Control of Thyristor Converter using PID Controller with Parallel Data Loop (데이터 병렬루프를 가지는 사이리스터 컨버터의 PID 점호각 제어)

  • Lee, Jae-Sung;Jang, Jin-Seok;Choo, Young-Bae;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.278-284
    • /
    • 2009
  • This paper presents a firing angle controller of a thyristor converter for DC power supply using PID controller with parallel data loop to improve the dynamic response. The proposed parallel data loop for firing angle controller of 3-phase semi-converter, generates pre-measured firing angle according to reference voltage and load current. With the approximated firing angle according to operating conditions, the output voltage can fast keep the reference value with small voltage error. And the PID controller compensates the output voltage error from the firing angle of parallel data loop. In order to reduce the sudden changing of the data from current ripple, a simple digital low pass filter is used to determine the output data. The proposed control scheme is verified by the experimental test of a practical 50[A] grade thyristor converter system.

The Power System for Home Appliance Air-Conditioner using Partial Switching Power Factor Correction Module (부분 스위칭 PFC 모듈을 이용한 가정용 에어컨 전원장치)

  • Suh, Ki-Young;Mun, Sang-Pil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.183-190
    • /
    • 2004
  • This paper proposes a methodology to solve problems upon the circuit design applied to inductor load by applying a circuit to improve power factor with is partial switching PFC module to the power supply system for cooling/heating inverter air conditioner and by designing an input power section in compliance with IEC555-2 on the basis of better input power factor and minimized harmonic components of current. On the other hand, this paper suggested how to control the increase of output voltage along with tぉw current waves and partial switching PFC circuit as well, which can provide the output as twice as input voltage This study applied a method to control the compressors of air conditioner by means of increased the voltage applicable to compressor motor by lowering switching number conclusively, it could solve questions about efficiency, economics, electronic noise and so forth. and so that the reasonable voltage for running moor could be set up along with lower power consumption of air conditioner than estimated It was demonstrated that total sum of energy efficiency to operate system was increased to the extent of valid level. And all this merits and appropriateness was proved by computer simulation and experience.