• Title/Summary/Keyword: Load compensator

Search Result 246, Processing Time 0.031 seconds

DSP Control of Three-Phase UPS Inverter with Output Voltage Harmonic Compensator (3상 UPS 인버터의 출력전압 왜형률 개선을 위한 고조파 보상기법의 DSP 제어)

  • 변영복;조기연;박성준;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.269-275
    • /
    • 1997
  • This paper presents real time digital signal processor(DSP) control of UPS system feeding processor(DSP) control of UPS system feeding nonlinear loads to provide sinusoidal inverter output voltage. The control scheme is composed of an rms voltage compensator, the load current harmonics feed-forward loop for the cancellation of output voltage harmonics, and the output voltage harmonics feedback loop for system stability. The controller employs a Texas Instruments TMS320C40GFL50 DSP.

  • PDF

Compensation of Highly Varying Load Effects Using SVCs (SVC를 이용한 Highly varying 부하 영향 보상 방안 개발)

  • Jung, Moon-Goo;Cho, Yun-Sung;Jang, Gil-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.83-87
    • /
    • 2001
  • This work deals with the compensation of the impact of highly varying loads on the power system using a static var compensator(SVC). Highly varying loads is properly modelled via deterministic approach using PSCAD/EMTDC. Also, the procedure to determine a suitable capacity of the compensator is proposed. Finally, the new online index to quantify the harmonic distortion is introduced.

  • PDF

Design of Voltage Unbalance Compensator in Cascaded H-bridge Multilevel STATCOM with Unbalanced Load (불평형 부하를 가지는 Cascaded H-bridge Multilevel STATCOM에서 전압불평형 보상기의 설계)

  • Kim, Tae-Hyeong;Kwon, Byung-Ki;Jung, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.128-129
    • /
    • 2013
  • 본 논문에서는 전기로 부하에서 발생하는 무효전력 성분과 역상분 전류를 보상하기 위한 STATCOM(STATic synchronous COMpensator)을 Cascaded Multilevel Converter(CMC)로 구성하는 경우 역상분 전류 보상시에 발생하는 직류전압의 불평형을 보상하기 위한 방법을 제안하고, 이를 시뮬레이터를 통해 검증하였다.

  • PDF

Performance Analysis of load simulator interconnected with Power Quality Compensator (전력품질 보상기와 부하모의장치의 연계시험 분석)

  • Bae, Byung-Yeol;Cho, Yun-Ho;Park, Yong-Hee;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.1
    • /
    • pp.89-97
    • /
    • 2007
  • This paper describes a load simulator with power recovery capability, which is based on the voltage source converter-inverter set. The load simulator can save the electric energy that should be consumed to test the operation and performance of the power quality compensator and the power equipment. The load simulator consists of a converter-inverter set with a DSP controller for system control and PWM pulse generation. The converter operates as a universal load to model the linear load and the non-linear load, while the inverter feed the energy back to the power source with harmonic compensation. the performance of proposed load simulator was analyzed with scaled-model experiment, interconnected with the active power filter. The experimental results confirms that the proposed load simulator can be utilized to test the performance of active power filter.

Steady-state Operational Strategies of UPFC in the KEPCO Transmission System

  • Chang, B.H.;Choo, J.B.;Xu, X.K.;Lam, B.P.
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.3
    • /
    • pp.161-167
    • /
    • 2003
  • This paper presents a study performed to investigate the steady-state operational strategies of UPFCs in the Jeollanam-Do system in Korea. The objective of the study was to determine the UPFC operating points under normal and contingency conditions. The study consists of developing load flow models to simulate different load levels with and without UPFCs in the system, assessing the effectiveness of UPFCs by contingency analysis, and introducing optimal corrective actions for removing voltage problems caused by contingencies. The paper describes analytical tools, models and approach. It also includes analysis and discussion of the study results. The paper contributes to the area of transmission operational studies with FACTS applications.

A Design of Optimal GA-PI Controller of Power System with SVC to Improve System Stability (시스템 안정도 향상을 위하여 SVC를 포함한 전력계통의 최적 GA-PI 제어기 설계)

  • 정형환;허동렬;이종민;주석민
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.63-71
    • /
    • 2000
  • This paper deals with a systematic approach to GA-PI controller design for static VAR compensator(SVC) using genetic algorithm(GA) to improve system stability. Genetic algorithms(GAs) are search algorithms based on the mechanics of natural selection and natural genetics. To verify the validity of the proposed method, investigated damping ratio of the eigenvalues of the electro-mechanical modes system with and without SVC. Also, we considered dynamic response of terminal speed deviation and terminal voltage deviation by applying a power fluctuation at heavy load, normal load and light to verify the robustness of the proposed. Thus, we proved usefulness of GA-PI controller design to improve the stability of single machine-bus with SVC system.

  • PDF

Simple Adaptive Position Control of a Hydraulic Cylinder-load System Driven by a Proportional Directional Control Valve (비례 방향제어 밸브에 의하여 구동되는 유압실린더-부하계의 단순 적응 위치제어)

  • Cho, Seung-Ho;Lee, Min-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.8
    • /
    • pp.936-941
    • /
    • 2011
  • This paper deals with the issue of motion control of a single rod cylinder-load system using simple adaptive control (SAC) method. Prior to controller design, the experiment of open-loop response has been performed. Based on it, design parameters of transfer function are obtained and used for controller design. The effect of parallel feedforward compensator has been investigated by computer simulation, suppressing the oscillatory motion. Through experiments it is conformed that the SAC method gives good tracking performance compared to the PD control method.

Motion Control of a Single Rod Cylinder-Load System Driven by a Proportional Directional Control Valve (비례방향제어밸브에 의해 구동되는 차동 실린더 부하계의 운동제어)

  • Lee, M.W.;Cho, S.H.
    • 유공압시스템학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.81-85
    • /
    • 2010
  • This paper deals with the issue of motion control of a single rod cylinder-load system using simple adaptive control (SAC) method. Prior to controller design, the experiment of open-loop response has been performed. Based on it, design parameters of transfer function are obtained. The effect of parallel feedforward compensator has been investigated by computer simulation, suppressing the oscillatory motion. Through experiments it is conformed that the SAC method gives good tracking performance compared to the PD control method.

  • PDF

Comparative study of control strategies for the induction generators in wind energy conversion system

  • Giribabu, D.;Das, Maloy;Kumar, Amit
    • Wind and Structures
    • /
    • v.22 no.6
    • /
    • pp.635-662
    • /
    • 2016
  • This paper deals with the comparison of different control strategies for the Induction generators in wind energy conversion system. Mainly, two types of induction machines, Self excited induction generator (SEIG) and doubly Fed Induction generators (DFIG) are studied. The different control strategies for SEIG and DFIG are compared. For SEIG, Electronic load Controller mechanism, Static Compensator based voltage regulator are studied. For DFIG the main control strategy namely vector control, direct torque control and direct power control are implemented. Apart from these control strategies for both SEIG and DFIG to improve the performance, the ANFIS based controller is introduced in both STATCOM and DTC methods. These control methods are simulated using MATLAB/SIMULINK and performances are analyzed and compared.

A Study on the Operating-Mode Characteristics of Two-Module Thyristor Controlled Series Compensator (Two-Module TCSC의 운전모드 특성 연구)

  • Jeong, Gyo-Beom
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.11
    • /
    • pp.1410-1416
    • /
    • 1999
  • This paper aims at investigating the operating-mode characteristics of two-module Thyristor Controlled Series Compensator (TCSC) as an equivalent of the multi-module TCSC in a simple three-phase power transmission system. The load flow program is developed to analyze the steady-state characteristics of two-module TCSC system and to find the thyristor firing angles for the required real power flow. The stability calculation program is developed with Poincare mapping theory. Simulation studies of the TCSC power transmission system using EMTP are performed to evaluate the transient characteristics of two-module TCSC as a real power flow controller and to rpove the results of the load flow calculation and the stability analysis. In the process of the study, the operating-mode characteristics of two-module TCSC are evaluated and compared to those of single-module TCSC.

  • PDF