• Title/Summary/Keyword: Load Transient Response

Search Result 227, Processing Time 0.024 seconds

Hydroelastic Responses of a Very Large Floating Structure in Time Domain (시간영역에서 초대형 부유식 해양구조물에 대한 유탄성 운동해석)

  • 이호영;신현경
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.04a
    • /
    • pp.18-22
    • /
    • 2000
  • This paper is transient motions of a very large floating structure subjected to dynamic load induced by wave. A time domain method is applied to the hydroelasticity problems for this purpose. The method is based on source-dipole and FEM scheme and on Newmark $\beta$ method to pursuit time step process taking advantage of the memory effect. The present method is appied to hydroelastic response analysis in regular waves and impact responses due to dropping aircraft.

  • PDF

Multi-cracking modelling in concrete solved by a modified DR method

  • Yu, Rena C.;Ruiz, Gonzalo
    • Computers and Concrete
    • /
    • v.1 no.4
    • /
    • pp.371-388
    • /
    • 2004
  • Our objective is to model static multi-cracking processes in concrete. The explicit dynamic relaxation (DR) method, which gives the solutions of non-linear static problems on the basis of the steady-state conditions of a critically damped explicit transient solution, is chosen to deal with the high geometric and material non-linearities stemming from such a complex fracture problem. One of the common difficulties of the DR method is its slow convergence rate when non-monotonic spectral response is involved. A modified concept that is distinct from the standard DR method is introduced to tackle this problem. The methodology is validated against the stable three point bending test on notched concrete beams of different sizes. The simulations accurately predict the experimental load-displacement curves. The size effect is caught naturally as a result of the calculation. Micro-cracking and non-uniform crack propagation across the fracture surface also come out directly from the 3D simulations.

A Study on Power System Stabilization using the Design of the Fuzzy PID Controller (퍼지 PID제어기틀 이용한 전력계통의 안정화장치에 관한 연구)

  • Chung, Hyeng-Hwan;Chung, Dong-Il;Joo, Seok-Min;Koh, Hee-Seog
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.86-88
    • /
    • 1995
  • This paper presents a design technique of the fuzzy PID controller for power system stabilization. PID parameters of the fuzzy PID controller was self-tuned by the fuzzy inference algorithm. The Nosed controller compare with conventional power system stabilizer(PSS) under various of initial value of rotor angle deviation and load condition. The related simulation results show that the Nosed controller was more excellent control characteristics than conventional PSS in transient-state and steady-state response.

  • PDF

A Study on the Position Control of BLDC Motor with New Sliding Surface. (새로운 슬라이딩면을 가지는 BLDC 모터의 위치제어에 관한 연구)

  • Lee, Dae-Sik;Park, Soo-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.80-82
    • /
    • 1997
  • A robust position control system for a BLDC motor using new sliding mode control strategy is presented. Using the new variable structure system, reaching phase problem is eliminated and transient response is largely improved by design of nonlinear sliding surface. The design of the sliding mode position controller is robust in motor parameter, load variations and disturbance. Experiment results show that the proposed approach can achieve accurate position motor tracking in face of large parameter variations and external disturbances, such as a robot arm, etc.

  • PDF

Modeling and Simulation of Loss of Excitation of Hydro Generator Control System (수력 발전기 제어시스템의 계자상실 모델링과 시뮬레이션)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.74-80
    • /
    • 2014
  • Generator protection device has to detects an internal fault conditions in generator and abnormal operating conditions must be due to the hazards. Loss of excitation may cause generator itself failure as well as serious operating problem in power system, and then requires an appropriate response of generator protection device. Details modeling of generator control system and analysis of transient states in generator are important for optimal operation in power plants. In addition, the fault simulation data are also used for testing the characteristics of IED. In this paper, the hydro generator control system using PSCAD/EMTDC, visual simulation for power systems, was modeled. The generator control system which is composed of generator, turbine, exciter, governor was implemented. The parameters of generator control system model were obtained from field power plant. Loss of excitation simulations were performed while varying the fixed load. Several signals analysis were also performed so as to analyze transients phenomena.

A Study on Operation Scheme of STS with Emergency Generator for Peak Shedding (첨두부하 저감을 위한 비상발전기 연계형 STS 운영 방안에 관한 연구)

  • Kim, Chang-Hwan;Rhee, Sang-Bong;Kim, Kyu-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.155-156
    • /
    • 2015
  • Recently, electricity consumption has rapidly increased along with economic growth. The operating strategy using emergency generator is aimed, to resolve a demand response management. For strategy of peak shedding using emergency generator, it is essential to introduce the fast transfer switching device. One of the most effective solutions is to use a static transfer switch (STS) based on thyristor. However, the characteristic of natural commutated SCR thyristor should anticipate short duration voltage sag. STS system thus requires more than a quarter cycle to successfully complete transfer process. This paper proposes the operation scheme of the STS system using the forced-commutation technique to mitigate instantaneous voltage sag during peak transfer process. Proposed STS system improved turn-off characteristic thus accomplishes the peak load shedding satisfied power quality. Performance of the proposed STS system is evaluated using electromagnetic transient program (EMTP) to confirm the effectiveness.

  • PDF

A Study on the Islanding Detection for Grid Connected Photovoltaic System (계통연계형 태양광발전시스템을 위한 단독운전 검출에 관한 연구)

  • Lee Gi-Je;Kim Min;Lee Jin-Seop;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.555-558
    • /
    • 2002
  • The general ways of the anti-islanding can be classified into the active method and passive method. The passive method which use only the voltage information when power failure occurs has much possibility of the wrong detection. And the active method detects the change of the voltage frequency as instantaneously changing the frequency of the inverter output current. Therefore, in this paper, the method to inject arbitrary order harmonics into controlled current is proposed. In this method islanding can be detected by measuring the amount of load voltage of injected harmonics order. And as a current control method predictive control method is used, which make actual current accurately to track reference current by Instantaneously computing converter output voltage and has fast response in transient state. This parer proposed method was verified by simulation.

  • PDF

Study on the Capacitor-self-excited Three-phase Synchronous Generator (A 캐패시터 자력식 삼상동기발전기에 관한 연구)

  • 정연택;김영동
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.11
    • /
    • pp.425-432
    • /
    • 1984
  • This paper is to propse a new self-excitation method of synchronous generator. Instead of conventional exciter of synchronous generator, the additional winding which is arranged in addition to the armature winding, is used in this generator. The output terminal of the additional winding is connected to a capacitor and to a full wave rectifier in series. In this configuration, one source double excitation which is composed of capacitor-self-excitation by lead urrent and direct current excitation by rectifier, is induced. The result is that` The excetation efficency is improved greatly and output waveform is improved also. In three-phase synchronous generator using the new method of the one source double excitation, voltage element (shunt characteristics) and current element (series characteristics)are compounded in scalar by adapting star-point-open-rectifier system. The result is as following` The effect of load power factor angle on voltage regulation is reduced greatly, compound characteristics is become manifold by controlling capacity of capacitor, and transient response is improved.

  • PDF

Analysis of Dry CVT Vehicle with a Torque Cam (토크 캠 장착 건식 CVT 차량의 성능 해석)

  • 김현석;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.4
    • /
    • pp.131-138
    • /
    • 2001
  • In this paper, performance of a dry CVT vehicle with torque cam is investigated. Based on belt transmission mechanism and torque cam actuator characteristics, an algorithm which is able to calculate the speed ratio from given thrust and load torque is suggested and a 3-D map is constructed for the speed ratio-thrust-torque. Using the 3-D map, a steady state characteristic of torque cam and a transient response of a dry CVT vehicle are investigated by simulation. It is found that initial spring compression plays a key role in determining the sliding criteria and the speed ratio velocity.

  • PDF

Dynamic Behaviour of a Radial Compliant Crank Mechanism Used in Scroll Compressor (스크롤 압축기에 적용된 가변반경 크랭크 기구의 동적 거동에 관한 연구)

  • 김태종;한동철
    • Tribology and Lubricants
    • /
    • v.12 no.2
    • /
    • pp.8-19
    • /
    • 1996
  • Scroll compressor using a slide bushing type radial compliant crank mechanism is modelled, and it's dynamic behaviour characteristics are analyzed. Sealing forces generated in the flank surfaces of the orbiting scroll depending on the distance, e, from slide bushing center to crank pin center are calculated. From the stable condition of orbiting scroll for the moment equilibrium in tangential direction, the range of e is determined as 0$r_o$. Transient response of a crankshaft supported by two journal bearings is investigated, considering applied load, moment, and unbalance force by eccentric mass. As a result, conical whirl mode with circular orbits are obtained. The characteristics of journal orbits and frictional losses are calculated with a variation of viscosity and bearing clearance.