• 제목/요약/키워드: Load Test System

검색결과 2,123건 처리시간 0.028초

다구찌법을 이용한 운전석 에어백의 강건설계 (Robust Design of a Driver-Side Airbag Using the Taguchi Method)

  • 이권희;주원식
    • 한국자동차공학회논문집
    • /
    • 제12권2호
    • /
    • pp.131-138
    • /
    • 2004
  • In the proto design stage of a new car, the performances of an occupant protection system can be evaluated by CAE even though the real test should be carried out. The number of the real test is reduced by the exact predictions followed by the appropriate design recommendation. However, the existing researches using CAE in predicting the performances do not consider the uncertainties of parameters. That often leads to inconsistency between test and CAE. In this research, the robust design of a protection system such as airbag and load limiter is suggested considering the frontal crash. The parameter design scheme of the Taguchi method is introduced to obtain the robust design of arbitrary airbag and load limiter. It is performed based on the frontal crash test condition of US-NCAP with an arbitrary passenger car. The variances of the performances such as HIC, chest acceleration and probability of combined injury are calculated by the outer array and the Taylor series expansion. Through the analysis of the Taguchi method, the robust optimum is determined.

TDX-10 패킷처리기의 성능척정을 위한 트래픽발생기의 설계 (Traffic Generator for Performance Test of the TDX-10 Packet Handler)

  • 정중수;전경표
    • 전자공학회논문지A
    • /
    • 제32A권3호
    • /
    • pp.411-417
    • /
    • 1995
  • Packet switching is an important aspect of ISDN. In the TDX-10 switching system, which is being developed as an ISDN exchange in Korea, the packet switching function is implemented on the basis of Case B scenario of X.31. After implementing the packet switching function the performance test must be executed to check whether the design objectives of performance are satisfied or not. However, it is not easy to set up test environment for performance measurement under full load conditions. This paper presents the design of the traffic generator which enables us to do performance test of the TDX-10 packet handler under full load conditions. To generate packet traffic we change only software programs without any change of the hardware system of the packet handler.

  • PDF

부하평준화 기능을 고려한 주택용 ESS의 적정 지원금 산정에 관한 연구 (A Study on the Decision of Appropriate Subsidy Levels for Energy Storage Systems Considering Load Leveling in Smart Place)

  • 김정훈;황성욱;이학주
    • 전기학회논문지
    • /
    • 제63권2호
    • /
    • pp.211-216
    • /
    • 2014
  • Construction of power plants and T&D facilities is so difficult because of the civil complaints and the additional cost according to the concerning field conditions. Therefore, various researches and methods have been considered to get solutions in the demand side and energy storage systems have been in the spotlight because of the various functions such as peak shaving, load shifting, and power system stabilizing, and so on. Residential small size batteries are considered in this paper and the economic analysis is carried out to evaluate the reasonable subsidy levels for the deployment of energy storage systems. Various economic parties are considered to find reasonable subsidy level comparing each other, which parties consist of utilities, participants and non-participants in general. The evaluation is based on California Standard Practice Test and the results are able to be used as subsidy guidelines.

냉방부하 변동을 고려한 빙축열시스템의 경제적 운전방식 (Control strategy for economic operation of an ice-storage system considering cooling load variation)

  • 정성훈;이대영;강병하;김우승
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.140-149
    • /
    • 2000
  • A comparative analysis was peformed on the operation cost at partial loads between ice storage systems with the two conventional control strategies, i.e., storage priority and chiller priority. The storage priority control is shown to be more economic for small cooling loads, while the chiller priority control is superior when the cooling load is as large as the design value. Based on this finding, a new control strategy is devised for an ice-storage system to minimize the operation cost at any cooling load. The new control strategy is found to be comparable to the chiller priority for large cooling loads, while it is more economic for small loads compared to the conventional control strategies. The practicality of the new control strategy is also confirmed through a performance test applying the new control strategy to an existing ice-storage system.

  • PDF

대형 멀티 전자기 가진 시스템의 구성 및 설계 (Configuration and Design of the Large Multi-Electromagnetic Shaking System)

  • 우성현;김홍배;문상무;김영기;임종민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.618-622
    • /
    • 2004
  • The vibration test system of SITC(Satellite Integration and Test Center) at KARI(Korea Aerospace Research Institute) has been used successfully for the environmental tests of a majority of korean space programs, such as KOMPSAT, Koreasat KITSAT, STSAT and KSR program since 1996. To meet the recent needs of large size test facility available for the vibrational tests of the huge launch vehicles and tole-communication satellites which will be developed in the near future, KARI undertook to construct the large size multi-electromagnetic shaking system with 3 $\times$ 3m head expander system. The new system will consist of three electromagnetic shakers which has 160 kN thrust force individually, and be able te sustain up to 8 tons test load and 300 kNm overturing moment. And to avoid the tremendous cost and effort to furnish the seismic block with large size and weight, it will adopt a Lin-E-Air type configuration with which the seismic block is less severe than a Solid-Truninon type. In addition, to fulfill the strong requirement of high overturning moment the additional guidance system including a central bearing system on a central support and several pad bearings around the head expander body is now considered. This paper describes the configuration and the design parameters of the multi-shaking system which is under development by KARI's engineers.

  • PDF

각 지역별 확률론적 신뢰도 평가에 관한 연구 (A Study on Nodal Probabilistic Reliability Evaluation at Load Points)

  • 김홍식;문승필;최재석;차준민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.206-209
    • /
    • 2001
  • This paper illustrates a new method for reliability evaluation at load points in a composite power system. The algorithm includes uncertainties of generators and transmission lines as well as main transformers at substations. The CMELDC based on the new effective load model at HLII has been developed also. The CMELDC can be obtain from convolution integral processing of the outage capacity probabilistic distribution function of the fictitious generator and the original load duration curve given at the load point. The CMELDC based on the new model at HLII will extend the application areas of nodal probabilistic production cost simulation, outage cost assessment and reliability evaluation etc. at load points. The characteristics and effectiveness of this new model are illustrated by a case study of a small test system.

  • PDF

항공기 조종면 부하재현 구동장치의 force control (QFT application on force controller design for aircraft control surface load simulator)

  • 남윤수;이진영;이기두
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1684-1687
    • /
    • 1997
  • A dynamic load simulator which can reproduce on-ground the hinge moment of aircraft control surface is and essential rig for the loaded performance test of aircraft test of aircraft acutation system. The hinge moment varies wide in the aricraft flight enveloped depending on specific flight condition and maneuvering status. To replicate the wide spectrum of this hinge moment variation within some accuracy bounds, a force controller is designed based on the Quantiative Feedback Theory (AFT). Through the analysis on hinge moment dynamics, a design specification for the force controller is suggested. The efficacy of QFT force controller is verivied by simulation, in which combined aricraft dynamics/flight control law and hydraulic actuation system dynamics of aircraft control surface are considered.

  • PDF

윤하중조건에서의 프리캐스트 콘크리트 바닥판 피로특성 (Fatigue Characteristics of Precast Concrete Bridge Decks under Wheel Load Condition)

  • 주봉철;박흥석;김영진;송재준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.394-397
    • /
    • 2006
  • For checking fatigue safety and endurance of precast concrete deck and loop joint system in the steel plate girder composite bridge, the test composite bridge model was made for the fatigue experiment by the wheel load machine. The fatigue tests of 1,000,000 cycles were implemented according to wheel load condition of DB24 rear axle of Korea Highway Design Code. From the test results, the loop joint system for the precast deck has a sufficient flexural capacity. Although a little lower longitudinal continuity capacity is evaluated than general sound cast-in-place RC bridge deck, there is no problem about the safety. The overall fatigue level of safety defined by the code is satisfied.

  • PDF

Load-carrying capacities and failure modes of scaffold-shoring systems, Part I: Modeling and experiments

  • Huang, Y.L.;Chen, H.J.;Rosowsky, D.V.;Kao, Y.G.
    • Structural Engineering and Mechanics
    • /
    • 제10권1호
    • /
    • pp.53-66
    • /
    • 2000
  • This paper proposes a simple numerical model for use in a finite analysis (FEA) of scaffold-shoring systems. The structural model consists of a single set of multiple-story scaffolds with constraints in the out-of-plane direction at every connection joint between stories. Although this model has only two dimensions (termed the 2-D model), it is derived from the analysis of a complete scaffold-shoring system and represents the structural behavior of a complete three-dimensional system. Experimental testing of scaffolds up to three stories in height conducted in the laboratory, along with an outdoor test of a five-story scaffold system, were used to validate the 2-D model. Both failure modes and critical loads were compared. In the comparison of failure modes, the computational results agree very well with the test results. However, in the comparison of critical loads, computational results were consistently somewhat greater than test results. The decreasing trends of critical loads with number of stories in both the test and simulation results were similar. After investigations to explain the differences between the computationally and experimentally determined critical loads, it was recommended that the 2-D model be used as the numerical model in subsequent analysis. In addition, the computational critical loads were calibrated and revised in accordance with the experimental critical loads, and the revised critical loads were then used as load-carrying capacities for scaffold-shoring systems for any number of stories. Finally, a simple procedure is suggested for determining load-carrying capacities of scaffold-shoring systems of heights other than those considered in this study.

에어컨부하 직접제어시스템 실증시험 및 운용방안에 관한 연구 (The Study on the Field test and Operational Method of a Direct Load Control System for Air conditioner)

  • 강원구;김충환;김명수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2825-2827
    • /
    • 2000
  • In electric power industry. load balance has been one of the most fundamental and important management goals. Therefore. the strategy to achieve high quality load management now includes load balance besides the stabilization of electricity supply and quality management of electricity. Amongst many techniques of load management. direct load management has been actively studied and utilized to increase power facility and peak load suppression. Higher peak load situation is appeared during summer than during winter in Korea. and approximately 20% of the peak load is due to the load for air-conditioning. To cope with this peak load problem during summer KEPCO is performing a research project to develop a system to remotely control air-conditioning load using wireless communication. Currently, applicable facilities are limited to small-scale air-conditioning facility that has less than 2KW power capacity. This paper described the 1st year of efforts made in the study.

  • PDF