• Title/Summary/Keyword: Load Losses

검색결과 359건 처리시간 0.024초

간접 분사식 디젤기관 피스톤 결합체 마찰력 측정 장치의 개선 및 마찰력 측정 (Study on the Improved Measurement of Piston Assembly Friction Force in an IDI Diesel Engine)

  • 조성우;김승수
    • 한국자동차공학회논문집
    • /
    • 제3권2호
    • /
    • pp.77-85
    • /
    • 1995
  • Among mechanical friction losses in an engine, the piston assembly and cylinder components accounts for the majority of the losses. The movable bore technique has been developed and turned out to be the most reliable technique in measuring the instantaneous friction of piston assembly. The weakness of this system, however, was the presence of the protruded top of movable bore necessary for pressure balancing. Because of the protruded part the piston could not be taken out without disassembling the crankshaft. Present study was carried out with a system of removable top of the movable bore so that it was possible to make frequent piston removals. The effects from engine speed, oil viscosity, engine load and elastic contact pressure of piston rings on the frictional characteristics have been evaluated with the improved equipment. Also, frictions of each member of piston assembly were measured.

  • PDF

Comparison of Transverse Flux Rotary Machines with Different Stator Core Topologies

  • Lee, Jiyoung;Chung, Shiuk;Koo, Daehyun;Han, Choongkyu
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.146-150
    • /
    • 2014
  • The objective of this paper is to provide a comparison between two transverse flux rotary machines (TFRM) with different topologies of stator cores. Depending on how to make stator core with laminated steel sheets, the one topology is 'perpendicular stacking core' and the other is 'separated core'. Both of the two cores have been designed considering 3-dimensional (3-D) magnetic flux path with the same output power conditions, but the core losses are quite different and it causes different magnetic and thermal characteristics. For comparison of these two topologies of stator cores, therefore, core losses have been calculated and used as a heat source in no-load conditions, and the thermal stress has been also calculated. 3-D finite element method has been used for the magnetic field, thermal, and stress analysis to consider the 3-D flux path of the TFRM. After comparing the analysis results of the two topologies, experimental results are also presented and discussed.

태양광 발전 시스템을 위한 부스트 컨버터의 회로 구성에 따른 직류측 스위치 손실 분석 (DC Link Switch Loss Analyses according to Circuit Structures of the Boost Converter for Photovoltaic Generation System)

  • 이승요
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.192-198
    • /
    • 2012
  • Switch losses directly affect the efficiency of power conversion systems and those have big differences according to the power consumed by load systems and the structures of power conversion circuits. In this paper, analyses for switch losses in DC link converter are performed based on the circuit structures of the DC/DC converter in photovoltaic generation system whose output power is varied according to the amount of solar radiation, temperature and partial shade on the solar modules. Boost converter is adopted as a DC link converter topology of the photovoltaic generation system and the loss analyses for the switches used in the boost converters are performed according to the circuit structures. Analyses like the things performed in this paper will be a prerequisite to designing the photovoltaic generation system whose output power is changed according to the environmental variations.

Finite Element Study of Ferroresonance in single-phase Transformers Considering Magnetic Hysteresis

  • Beyranvand, Morteza Mikhak;Rezaeealam, Behrooz
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.196-202
    • /
    • 2017
  • The occurrence of ferroresonance in electrical systems including nonlinear inductors such as transformers will bring a lot of malicious damages. The intense ferromagnetic saturation of the iron core is the most influential factor in ferroresonance that makes nonsinusoidal current and voltage. So the nonlinear behavior modeling of the magnetic core is the most important challenge in the study of ferroresonance. In this paper, the ferroresonance phenomenon is investigated in a single phase transformer using the finite element method and considering the hysteresis loop. Jiles-Atherton (JA) inverse vector model is used for modeling the hysteresis loop, which provides the accurate nonlinear model of the transformer core. The steady-state analysis of ferroresonance is done while considering different capacitors in series with the no-load transformer. The accurate results from copper losses and iron losses are extracted as the most important specifications of transformers. The validity of the simulation results is confirmed by the corresponding experimental measurements.

동기 리럭턴스 전동기의 에너지 절감을 위한 효율 최적화 제어 (Efficiency Optimization Control for Energy Saving of Synchronous Reluctance Motor)

  • 이정철;이흥균;정동화
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.159-162
    • /
    • 2001
  • This paper is proposed an efficiency optimization operation algorithm for synchronous reluctance motor (SynRM) using current phase angle control technique. The SynRM has to controlled with the optimal current phase angles with load and operation speed variation, to obtain high efficiency over the wide speed ranges. An efficiency optimization condition in SynRM which minimizes the copper and iron losses is derived based on the equivalent circuit model of the machine. The objective of the efficiency optimization control algorithm compensating the optimum current angle, is to seek a combination of d and q-axis current components which provides minimum losses at a certain operating point in steady state. The usefulness of the proposed efficiency optimization control is verified through vector-controlled inverter system with the SynRM.

  • PDF

태양광 시스템용 단상 및 3-레벨 부스트 컨버터의 효율 및 전력밀도 비교 분석 (Comparative Analysis of Efficiency and Power Density of Single-Phase and 3-Level Boost Converters for PV System)

  • 김철민;김종수
    • 전력전자학회논문지
    • /
    • 제25권2호
    • /
    • pp.127-132
    • /
    • 2020
  • In this study, single-phase and three-level boost converters applied to the photovoltaic system were compared and analyzed in terms of efficiency and power density according to the input voltage and load conditions. For accurate analysis of efficiency, the losses in each device of the single-phase and three-level boost converters were derived using mathematical equations and simulations by using the PSIM thermal module. Then, the losses were compared with the efficiency confirmed through the actual experiments. Results confirmed that the efficiency and power density can be improved by applying the three-level boost converter to the system according to the selection of the switching frequency.

콘크리트포장에서 하중전달효과 영향인자 연구 (A Study on Effect Factor of Load Transfer Efficiency in Concrete Pavement)

  • 양홍석;서영찬;권수안
    • 한국도로학회논문집
    • /
    • 제3권3호
    • /
    • pp.147-158
    • /
    • 2001
  • 콘크리트포장의 구조적 능력을 평가하는 가장 중요한 요소 중의 하나는 하중전달효과이다. 하중전달효과는 슬래브 상 하부 온도차, 다우월바 시공여부, 포장 노후도, 그리고 균열틈 등에 영향을 받는다. 본 연구의 목적은 콘크리트 포장의 하중전달효과 특성을 파악하고 하중전달효과에 영향을 주는 요소를 정량화하고 적절한 하중전달효과 조사방법을 제시하는 것이다. 연구결과 하중전달효과는 슬래브 표면온도가 아닌 슬래브 평균온도 영향을 받는 것으로 나타났다. 하중전달효과는 온도가 내려가고 균열틈이 벌어질수록 감소하는 것으로 나타났다. 다우월바를 시공한 구간의 경우 온도변화에 따라 하중전달효과는 큰 차이를 보이지 않은 반면, 다우월바를 시공하지 않은 구간에서는 온도가 내려갈수록 하중전달효과는 급격히 감소하였다. 다우월바를 시공한 구간이라도 포장이 노후화되면 하중전달효과는 온도가 하락함에 따라 감소하는 것으로 나타났다. 본 조사대상 구간에서는 슬래브 단위온도 하락시 하중전달효과는 1.4% 감소하는 것으로 나타났다.

  • PDF

전기적인 거리를 고려한 한계송전손실계수 산정 방법론 개발 (Development of Evaluation Method for Transmission Marginal Loss Factors Considering the Electrical Distance)

  • 박종배;이기송;이찬주;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.488-490
    • /
    • 2003
  • This paprer presents the evlauation method for transmission marginal loss factors(MLFs) considering the electrical distance. Generally, MLFs are represented as the sensitivity of transmission losses, which is computed from the change of generation by the change of the load. MLFs are classified as load-focused MLFs and generator-focused MLFs. The existing evaluation method for generator focused MLFs has the limit not reflecting the characteristic of power systems since the method has been introduced the assumption which the output of a generator is supplied to all of the load buses on the power system. Therefore, to overcome the limit of evaluation method for generator-focused MLFs, we have applied the process, which it approximately can find the load buses that supplied a generator to the method. We have applied the proposed method to the simple 5-bus system because the proposed method is not analytic but the hybrid method incorporated the Kirschen and Bialek's algorithm to the existing analytic method to find the load buses supplied by a generator.

  • PDF

A New Dual-Active Soft-Switching Converter for an MTEM Electromagnetic Transmitter

  • Wang, Xuhong;Zhang, Yiming;Liu, Wei
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1454-1468
    • /
    • 2017
  • In this study, a new dual-active soft-switching converter is proposed to improve conversion efficiency and extend the load range for an MTEM electromagnetic transmitter in geological exploration. Unlike a conventional DC/DC converter, the proposed converter can operate in passive soft-switching, single-active soft-switching, or dual-active soft-switching modes depending on the change in load power. The main switches and lagging auxiliary switches of the converter can attain soft-switching over the entire load range. The conduction and switching losses are greatly reduced compared with those of ordinary converters under the action of the cut-off diodes and auxiliary windings coupled to the main transformer in the auxiliary circuits. The conversion efficiency of the proposed converter is significantly improved, especially under light-load conditions. First, the working principle of the proposed converter is analyzed in detail. Second, the relationship between the different operating modes and the load power is given and the design principle of the auxiliary circuit is presented. Finally, the Saber simulation and experimental results verify the feasibility and validity of the converter and a 50 kW prototype is implemented.

TCN 딥러닝 모델을 이용한 최대전력 예측에 관한 연구 (A Study on Peak Load Prediction Using TCN Deep Learning Model)

  • 이정일
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제12권6호
    • /
    • pp.251-258
    • /
    • 2023
  • 안정적으로 전력을 공급하고 전력계통을 운영하기 위해서는 최대전력을 정확히 예측해야 한다. 특히, 최대전력이 높게 발생하는 겨울과 여름에는 그 중요성이 매우 커진다. 최대전력을 실제 수요보다 높게 예측하면 발전소 기동 비용이 증가하여 경제적 손실이 발생하고, 최대전력을 실제 수요보다 낮게 예측하면 기동이 가능한 발전소가 부족하여 정전이 발생할 수 있다. 최대전력의 예측 오차를 최소화함으로써 경제적 손실과 정전을 예방할 수 있다. 본 논문에서는 최대전력 예측의 오차를 최소화하기 위하여 최신 딥러닝 모델인 TCN을 이용한다. 딥러닝 모델은 하이퍼 파라미터를 어떻게 설정하느냐에 따라 성능 차이가 발생하므로, TCN의 하이퍼 파라미터를 최적화하는 방법을 제안한다. 2006년부터 2021년까지의 데이터를 입력하여 모델을 훈련하고, 2022년의 데이터를 이용하여 예측 오차를 실험하였다. 실험을 수행한 결과 본 논문에서 제안한 최적화 방법을 이용한 TCN 모델의 성능이 다른 딥러닝 모델보다 성능이 우수한 것을 확인하였다.