This study was conducted to establish the control program for preventing unfavorable health effects of nitrogen dioxide($NO_2$) exposure in homes by preparing the fundamental data for evaluation of relation-ships between $NO_2$ levels and influencing factors through measurements of indoor-outdoor $NO_2$ levels and personal $NO_2$ exposures for housewives with questionnaire survey on 172 homes in Pusan area from April to June, 1987 $NO_2$ measurements were made by using diffusion tube samplers(Palmes tube $NO_2$ sampler) for one week at 4 sites in homes ; kitchen(KIT), bedroom(BED), living room(LIV), outdoor(OUT) and near the collar of housewives(personal exposure livel, PNO). The details of questionnaire were number of household members(FAM), number of regular smokers (SMOKER), daily number of meals eaten(MEAL), type of housing units(HOUSE), location of house with distance from the heavy traffic roads as walking time(DIST), and of kitchen(KAREA), kind of cooking fuels(FUEL), cooking time of each meal(CTIME), usage of kitchen fan for cooking(FAN), type of heating facilities(HEAT) and so on of subject homes. The Obtained results were as fellows : 1) The mean $NO_2$ level was significantly higher at indoors than outdoors(p<0.01) and the kitchen $NO_2$ level was the highest with $33.7{\pm}13.6ppb$(9.5-81.5ppb). The mean personal exposure level of $NO_2$ for housewives was $20.6{\pm}8.8ppb$(3.1-46.9ppb). 2) The mean indoor $NO_2$ level was significantly higher in the group of household members above 5 than below 4(p<0.05), in detached dwellings than apartments(p<0.001), within 5 minutes of distance than over 5 minutes(p<0.001), in the group of unusing fan(p<0.001), in the group of longer cooking time(p<0.001), and it was in order of coal briquette, gas, electricity and oil by kind of cooking fuels(p<0.05). 3) Variables showing significant correlation(p<0.001) with indoor $NO_2$ level were kitchen $NO_2$ level(r=0.8677), cooking time(r=0.5921), outdoor $NO_2$ level(r=0.5192), personal $NO_2$ exposure level(r=0.4615), usage of kitchen fan(r=0.3573) and location of house(r=-0.2988) 4) As a result of multiple regression analysis, the most significant influencing variable to the kitchen $NO_2$ level was cooking time[KIT=$-0.378{\pm}11.772$(CTIME)+0.298(OUT)+3.102(FAN)], it was kitchen $NO_2$ level to the indoor $NO_2$ level[IND=6.996+0.458(KIT)+0.230(OUT)-1.127(KAREA)], and it was indoor $NO_2$ level to the personal $NO_2$ exposure level[PNO=15.562+0.729(IND)-4.542(DIST)-0.200(KIT)] 5) It was recognized that aritificial ventilation in the kitchen, suppression of unnecessary combustion and replacement of cooking fuel, as much as possible, were effective means for decreasing indoor $NO_2$ levels in homes.