• Title/Summary/Keyword: Liver CT Scan

Search Result 98, Processing Time 0.025 seconds

Computer Tomography and Magnetic Resonance Image Manifestations of Primary Hepatic Neuroendocrine Cell Carcinomas

  • Huang, Juan;Yu, Jian-Qun;Sun, Jia-Yu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2759-2764
    • /
    • 2014
  • Aim: This study aims to investigate the manifestation of CT, MRI and dynamic enhanced scans for primary hepatic neuroendocrine cell carcinoma. Methods: CT or MRI arterial and venous phase scan images of 19 cases of pathologically confirmed PHNEC were retrospectively analyzed. Results: 14 cases (73.68%) with single lesion, 5 cases (26.3%) with multiple lesions, with an average diameter of 13.2 cm. Some 12 cases (63.16%) showed inhomogeneous enhancement, seven cases (36.8%) showed homogeneous enhancement, 13 cases (68.4%) demonstrated significant enhancement in the arterial phase, 13 cases (68.4%) had significantly enhanced portal venous phase including 7 cases (36.8 %) with portal venous phase density or signal above the arterial phase and 5 cases (26.3%) with the portal vein density or signal below the arterial phase. Seven cases (36.8%) had continued strengthened separate shadows in the center of the lesion. Thrombosis were not seen in portal veins. Conclusion: CT and MRI images of liver cell neuroendocrine carcinoma have certain characteristics that can provide valuable information for diagnosis and differential diagnosis.

Diaphragmatic Hernia of the Right Hepatic Lobe Mistaken for Diaphragmatic Paralysis in Adult (성인에서 횡격막마비로 오인한 우엽간 횡격막탈장 1예)

  • Park, Jung-Hyun;Hwang, Ki-Eun;Kim, So-Young;Kim, Hak-Ryul;Yang, Sei-Hoon;Kim, Hwi-Jung;Jeong, Eun-Taik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.5
    • /
    • pp.298-300
    • /
    • 2010
  • Diaphragmatic paralysis can be demonstrated through diaphragmatic elevation on chest X-ray after thoracic lung surgery or the placement of chest tubing. Additional causes of diaphragmatic paralysis are iatrogenic, mass, atelectasis, etc. For the diagnosis of diaphragmatic paralysis, it required some studies (fluoroscopy, computed tomography [CT], magnetic resonance imaging). Diaphragmatic hernia of the liver is a rare clinical entity, usually found after trauma in adults. Congenital diaphragmatic hernia in neonates requires surgery. Non-traumatic diaphragmatic hernia of the liver in an adult is a rare right-sided diaphragmatic hernia. On developing any symptoms, surgery must be performed. When diaphragmatic hernia is incidentally found in adults without trauma, it is placed under observation for a time period. We diagnosed the diaphragmatic herniation of a right hepatic lobe by 16-slice CT scan without surgery.

Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

The effect of atrophied pancreas as shown in the preoperative imaging on the leakage rate after pancreaticoduodenectomy

  • Ashraf Imam;Harbi Khalayleh;Meni Brakha;Ariel A. Benson;Naama Lev-Cohain;Gidon Zamir;Abed Khalaileh
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.26 no.2
    • /
    • pp.184-189
    • /
    • 2022
  • Backgrounds/Aims: The soft texture of the pancreas parenchyma may influence the incidence of pancreatic leakage after pancreaticcoduodenectomy (PD). One possible method to assess pancreatic texture and atrophy, is via computed tomography (CT) scan of the abdomen. The purpose of our study was to evaluate the relation between the preoperative CT scan and the incidence of pancreatic fistula after PD. Methods: A retrospective single-center study including patients who underwent PD for a benign and malignant tumor of the periampullary region between the years 2000 and 2016. Demographic and imaging data were analysed and a correlation with the post-operative leak was evaluated. Results: Pancreatic leak was documented in 34 out of 154 (22.1%) patients. All the leakage cases occurred in the preserved pancreas group (33.1% of the total preserved pancreas group alone). No leak was documented in the atrophic pancreas group. This difference between the two groups was found to be statistically significant (p ≤ 0.00001). Conclusions: Atrophic pancreas in the preoperative CT scan may be protective against leakage after PD. These findings may help the surgeon to risk stratify patients accordingly. In addition, the findings suggest that patients with a preserved pancreas may require more protective methods to prevent leakage.

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.

  • PDF

A Case of Rhabdomyosarcoma in the Liver (간에서 발견된 횡문근육종 1례)

  • Lee, Dong-Jun;Yoon, Ji-Sung;Kim, Joon-Hwan;Park, Chan-Won;Suh, Jeong-Il;Lee, Heon-Ju;Kim, Ki-Kweon
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.2
    • /
    • pp.360-366
    • /
    • 1996
  • Pure primary hepatic rhabdomyosarcoma in adult is very uncommon. There have been only five previous case of primary rhabdomyosarcoma of the adult liver. A case of hepatic rhabdomyosarcoma was diagnosed in a 52 year-old female. She was admitted to the hospital due to the epigastric pain and weight loss. A CT scan of the abdomen showed a large hypodense mass with focal calcification occupies most of the both lobes of the liver. The liver biopsy showed massive liver tumor composed entirely of oval shaped cells showing light microscopic and immunohistochemical evidence of rhabdomyoblastic differentiation. We report a case of hepatic rhabdomyosarcoma with review of literature.

  • PDF

Investigation of the Effect of kV Combinations on Image Quality for Virtual Monochromatic Imaging Using Dual-Energy CT: A Phantom Study

  • Jeon, Pil-Hyun;Chung, Heejun;Kim, Daehong
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Background: In this study, we investigate the image quality of virtual monochromatic images synthesized from dual-energy computed tomography (DECT) at voltages of 80/140 kV and 100/140 kV. Materials and Methods: Virtual monochromatic images of a phantom are synthesized from DECT scans from 40 to 70 keV in steps of 1 keV under the two combinations of tube voltages. The dose allocation of dual-energy (DE) scan is 50% for both low- and high-energy tubes. The virtual monochromatic images are compared to single-energy (SE) images at the same radiation dose. In the DE images, noise is reduced using the 100/140 kV scan at the optimal monochromatic energy. Virtual monochromatic images are reconstructed from 40 to 70 keV in 1-keV increments and analyzed using two quality indexes: noise and contrast-to-noise ratio (CNR). Results and Discussion: The DE scan mode with the 100/140 kV protocol achieved a better maximum CNR compared to the 80/140 kV protocol for various materials, except for adipose and brain. Image noise is reduced with the 100/140 kV protocol. The CNR values of DE with the 100/140 kV protocol is similar to or higher than that of SE at 120 kV at the same radiation dose. Furthermore, the maximum CNR with the 100/140 kV protocol is similar to or higher than that of the SE scan at 120 kV. Conclusion: It was found that the CNR achieved with the 100/140 kV protocol was better than that with the 80/140 kV protocol at optimal monochromatic energies. Virtual monochromatic imaging using the 100/140 kV protocol could be considered for application in breast, brain, lung, liver, and bone CT in accordance with the CNR results.

Incidental Visualization of Hepatic Hemangioma by Tc-99m-HDP Bone Scan (골스캔에서 우연히 발견된 간혈관종)

  • Chung, Yong-An;O, Joo-Hyun;Kim, Jung-Ho;Yoo, Ie-Ryung;Kim, Sung-Hoon;Sohn, Hyung-Sun;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.4
    • /
    • pp.266-267
    • /
    • 2005
  • Hepatic hemangioma is the most common benign liver tumor and must be considered in the differential diagnosis of other space occupying hepatic masses. A 54-year-old man was referred to evaluate bone metastases of lung adenocarcinoma. In our case, we thought that a focal hepatic uptake in the bore scan was a metastatic lesion, because of underlying lung adenocarcinoma. However, the findings of abdominal CT and Tc-99m RBC scan results were deemed to be characteristic of hepatic hemangioma. The biopsy of the lesion was not performed.

Hepatic Pseudolymphoma Mimicking a Hypervascular Tumor: A Case Report (과혈관성 종양으로 오인된 간의 가성림프종: 증례보고)

  • Im, Bora;Jang, Suk Ki;Yeon, Jae Woo;Paik, So Ya;Park, Sang Jong;Kim, Hyuk Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.6
    • /
    • pp.348-353
    • /
    • 2018
  • Hepatic pseudolymphoma is a rare benign liver mass that is characterized by proliferation of non-neoplastic lymphocytes extranodally. To the best of our knowledge, only 46 cases have been reported in the English literature. We described the case of a 75-year-old woman with hepatic pseudolymphoma mimicking a hypervascular tumor. After the histological confirmation of the rectal neuroendocrine tumor, CT scan revealed a 1.0 cm-sized, poorly-defined and low-density nodule in the liver. On MRI, the hepatic nodule showed an arterial enhancement and a low-signal intensity on the hepatobiliary phase. On diffusion-weighted imaging, the hepatic nodule showed a high signal intensity on a high b-value. On fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT, it revealed a high standardized uptake value nodule. The US showed the hypoechoic nodule and the US-guided biopsy confirmed the hepatic pseudolymphoma.