• Title/Summary/Keyword: Liver CT Scan

Search Result 98, Processing Time 0.027 seconds

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Differential Absorption Analysis of Nonmagnetic Material in the Phantom using Dual CT

  • Kim, Ki-Youl;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.286-292
    • /
    • 2016
  • This study evaluates the change of computer tomography (CT) number in the case of the metal artifact reduction (MAR) algorithm, using the phantom. The images were obtained from dual CT using a gammex 467 tissue characterization phantom, which is similar to human tissues. The test method was performed by dividing pre and post MAR algorithm and measured CT values of nonmagnetic materials within the phantom. In addition, the changes of CT values for each material were compared and analyzed after measuring CT values up to 140 keV, using the spectral HU curve followed by CT scan. As a result, in the cases of N rod (trabecular bone) and E rod (trabecular bone), the CT numbers decreased as keV increasing but were constant above 90 keV. In the cases of I rod (dense bone) and K rod (dense bone), the CT numbers also decreased as keV increased but were uniform above 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of J rod (liver), D rod (liver), L rod (muscle), and F rod (muscle). For A rod (adipose), G rod (adipose), B rod (breast) and O rod (breast), the CT numbers increased as keV increased but were constant after 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of C rod (lung (exhale)), P rod (lung (exhale)), M rod (lung (inhale)) and H rod (lung (exhale)). Conclusively, because dual CT exhibits no changes in image quality and is able to analyze nonmagnetic materials by measuring the CT values of various materials, it will be used in the future as a useful tool for the diagnosis of lesions.

Measurements of the Hepatectomy Rate and Regeneration Rate Using Deep Learning in CT Scan of Living Donors (딥러닝을 이용한 CT 영상에서 생체 공여자의 간 절제율 및 재생률 측정)

  • Sae Byeol, Mun;Young Jae, Kim;Won-Suk, Lee;Kwang Gi, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.434-440
    • /
    • 2022
  • Liver transplantation is a critical used treatment method for patients with end-stage liver disease. The number of cases of living donor liver transplantation is increasing due to the imbalance in needs and supplies for brain-dead organ donation. As a result, the importance of the accuracy of the donor's suitability evaluation is also increasing rapidly. To measure the donor's liver volume accurately is the most important, that is absolutely necessary for the recipient's postoperative progress and the donor's safety. Therefore, we propose liver segmentation in abdominal CT images from pre-operation, POD 7, and POD 63 with a two-dimensional U-Net. In addition, we introduce an algorithm to measure the volume of the segmented liver and measure the hepatectomy rate and regeneration rate of pre-operation, POD 7, and POD 63. The performance for the learning model shows the best results in the images from pre-operation. Each dataset from pre-operation, POD 7, and POD 63 has the DSC of 94.55 ± 9.24%, 88.40 ± 18.01%, and 90.64 ± 14.35%. The mean of the measured liver volumes by trained model are 1423.44 ± 270.17 ml in pre-operation, 842.99 ± 190.95 ml in POD 7, and 1048.32 ± 201.02 ml in POD 63. The donor's hepatectomy rate is an average of 39.68 ± 13.06%, and the regeneration rate in POD 63 is an average of 14.78 ± 14.07%.

Incidental Extramammary Findings on Preoperative Breast MRI in Breast Cancer Patients: A Pictorial Essay (유방암 환자의 수술 전 유방 MRI에서 우연히 발견된 유방 외 소견: 임상화보)

  • Jin-A Ryoo;Shin Young Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.372-385
    • /
    • 2023
  • Breast cancer is one of the most common cancers and causes several complications in females. Currently, MRI is a necessary method for preoperative studies in patients with breast cancer. A high frequency of breast MRI can lead to an increase in the number of incidental extramammary findings. Moreover, it can provide accurate preoperative workup; therefore, the prognosis of patients can be improved. Herein, we provide several extramammary findings, including the mediastinum, lung, upper abdomen, bone, and soft tissue, correlating with US, chest CT, liver MRI, PET-CT, and bone scan.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

Evaluation of SUV Which was Estimated Using Mini PACS by PET/CT Scanners (PET/CT 장비 별 mini PACS에서 측정한 표준섭취계수(SUV)의 유용성 평가)

  • Park, Seung-Yong;Ko, Hyun-Soo;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.47-52
    • /
    • 2011
  • Purpose: Facilities use own sever or mini PACS system for storage and analysis of the PET/CT data. Mini PACS can storage scan data as well as measuring SUV. Therefore, the study was performed to confirm whether or not measured SUV on mini PACS is measured equally on PET/CT workstation. Materials and Methods: In February 2011, 30 patients who were performed $^{18}F$-FDG wholebody PET/CT scan in Biograph 16, Biograph 40 and Discovery Ste 8 were enrolled. First, using each workstation, SUV in liver and aorta of mediastinum level was measured. Second, using mini PACS, SUV was measured by same method. Result: The correlation coefficient of SUV in liver between PET/CT scanner and min PACS in Biograph 16, Biograph 40, Discovery Ste 8 was 0.99, 0.98, 0.64 respectably, the correlation coefficient of SUV in aorta was 0.98, 0.98, 0.66, and these were showed positive correlation coefficient. Difference of SUV between Biograph workstation and mini PACS was not showed statistical significant difference at 5% level of significance. Difference of SUV between Discovery Ste 8 workstation and mini PACS was showed statistical significant difference at 5% level of significance. Conclusion: In case that patient was scanned by the other scanner, if the correction of SUV formula in mini PACS for each scanners is performed, mini PACS will be usefully used to provide consistently quantitative assessment.

  • PDF

A Case of Hepatosplenic Tuberculous Abscess (간과 비장에서 발생한 결핵성 농양 1례)

  • Han, Yu Seok;Chung, Ju Young;Kim, Sang Woo;Kim, Sung Hee
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.7 no.1
    • /
    • pp.108-111
    • /
    • 2004
  • Tuberculosis is not a common cause of liver abscess and it is rarely considered in the differential diagnosis of a patient with hepatic mass. We report a case of tuberculous abscess of liver and spleen in a 15-year-old boy who presented with abdominal pain, fever and weight loss. The ultrasonographic and computed tomographic scan of the abdomen revealed multiple cystic lesions in the liver and spleen. Mycobacterium tuberculosis was cultured from the ascitic fluid and biopsy specimen of lymph node. Follow up CT scan of the abdomen after anti-tuberculosis medication for eighteen months showed complete resolution of the cystic lesions with calcified nodules.

  • PDF

A case of pyogenic liver abscess in a 10-year-old girl

  • Byun, Jung-Lim;Bae, Sun-Hwan;Park, Sang-Woo
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.5
    • /
    • pp.666-668
    • /
    • 2010
  • Pyogenic liver abscesses are rare in children. In pediatric patients, altered host defences seem to play an important role. However, pyogenic liver abscess also occurs in healthy children. We experienced a case of pyogenic liver abscess in a healthy immunocompetent 10-year-old-girl. The patient presented two distinct abscesses: one subphrenic and the other intrahepatic. The intrahepatic abscess resolved with percutaneous drainage and 3 weeks of parenteral antibiotic therapy but the subphrenic abscess which could not be drained needed prolonged parenteral antibiotic therapy in addition to oral antibiotic therapy. We performed follow-up serial CT scan of the abscess cavity to decide on the duration of antibiotic therapy. Here we present this case with a brief review of the literature.

The study on Standard Uptake Value(SUV) change according to time input difference in PET/CT scan (PET/CT 검사에서 시간 입력 차이에 따른 표준화섭취계수(SUV) 변화에 대한 고찰)

  • Kim, Kyung-Sik;Lee, Ju-Young;Jung, Woo-Young;Kim, Jung-Sun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.21-25
    • /
    • 2011
  • Purpose: $^{18}F$-FDG Fusion Whole Body PET scan is performed approximately 1 hour after injecting $^{18}F$-FDG. At this point in the injection procedure, as a tool of the criteria of time input, time of clocks or computers can be used and in the scan procedure, time of workstation can be used. In case that synchronized time input is not done in the injection and scan procedures for PET scan, time error from injection to scan can occur. This time error may affect Standard Uptake Value (SUV) being used as quantitative assessment. Therefore, in this study, we analyzed the change of SUV according to time input difference and necessity of time synchronization. Materials and Methods: The analysis was performed to 30 patients ($54.8{\pm}15.5$ years old) who examined $^{18}F$-FDG Fusion Whole Body PET scan in Department of nuclear medicine, Asan Medical Center from December 2009 to February 2010. To observe the change of SUV according to time input difference, the image was reconstructed and analyzed by artificially changing time difference of 1, 2, 3, 5, 10, 20 min against the same patients based on 60 minutes. Result: SUV of the image that reconstructed the images of 30 patients by giving intervals of 1, 2, 3, 5, 10, 20 min respectively and the image that entered original time was compared and analyzed through paired t-test. Based on 0 minute, mean SUV of aorta was changed by 0.3, 1.1, 1.4, 3.2, 4.7, 12.5% respectively and there was no statistically significant difference in 1, 2 minutes (p>0.05) but there was significant difference in 3, 5, 10, 20 min (p<0.05). The changes of $SUV_{avg}$ of liver were 1.6, 2.5, 3.0, 4.2, 6.6, 12.8% in 1, 2, 3, 5, 10, 20 min respectively and the changes of $SUV_{max}$ of primary lesion were 1.0, 1.5, 2.2, 3.5, 6.6, 12.8% respectively (p<0.05). Conclusion: Errors may occur in the process of measuring or recording variables affecting SUV such as height and weight of patients, $^{18}F$-FDG dose, Emission scan start time etc. and as these errors are more, the accurate assessment of SUV is interfered. Therefore, in order to assess SUV more accurately, it is thought that efforts to minimize these errors should be made. Of these efforts, time synchronization will be a cornerstone for accurate scanning.

  • PDF

A Case of Probable Mixed-Infection with Clonorchis sinensis and Fasciola Sp.: CT and Parasitological Findings

  • Kim, Tae-Yun;Lee, Yun-Sik;Yun, Ji-Hye;Kim, Jeong-Ju;Choi, Won-Hyung;Oh, In-Hwan;Song, Hyun-Ouk;Chu, Jong-Phil
    • Parasites, Hosts and Diseases
    • /
    • v.48 no.2
    • /
    • pp.157-160
    • /
    • 2010
  • We report here a human case probably mixed-infected with Clonorchis sinensis and Fasciola sp. who was diagnosed by computed tomography (Cn scan, serological findings, and/or fecal examination. The patient was a 43-year-old Korean female and was admitted to Kyung Hee University Hospital with the complaints of fever and abdominal pain. On admission, marked eosinophilia was noted in her peripheral blood. CT scan showed specific lesions for clonorchiasis and fascioliasis in the liver, along with lesions suggestive of amebic abscess. Micro-ELISA revealed positive results for the 2 helminthic infections. Eggs of C. sinensis and trophozoites of Entamoeba histo/ytica were observed in the stool. Treatment with praziquantel followed by metronidazole and tinidazole reduced abnormalities in the liver and eosinophilia. This is the first case report of a possible co-infection with 2 kinds of liver flukes in the Republic of Korea.