• Title/Summary/Keyword: Liver CT 검사

Search Result 109, Processing Time 0.026 seconds

Study to Protocol of PET Acquisition Time for Patient Body Type in PET/CT (PET/CT 검사에서 환자체형에 따른 적정검사 프로토콜에 관한 고찰)

  • Cho, Seok Won;Ham, Joon-Chul;Kang, Chun Goo;Bahn, Young Kag;Lee, Seung Jae;Lim, Han Sang;Lee, Chang-Ho;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.72-77
    • /
    • 2013
  • Purpose: Whole-body PET using radiopharmaceutical is one of the imaging study methods for physiological changes of body. High specificity of the PET-CT examination is used to detect an early stages of cancer and metastatic cancer by imaging a physiological changes. During the imaging process, PET image has been characterized by a relatively low image quality due to its low sensitivity and the acquisition of random and scatter coincidences as well as patients figure. Therefore, the image quality as the changes of the acquisition times of patient weight was evaluated in this study. Materials and Methods: Thirty patients who presented to our hospital were enrolled. They were divided to normal, overweight, and obese group using BMI index, respectively. The patients with a liver disease and diabetes were excluded. $^{18}F-FDG$ was administered to the patients as 5.2 MBq per kg. After an hour from an injection, image acquisition was obtained as List mode in a part of liver in 1 bed. SNR (signal-to-noise ratio) of each groups acquisition times were confirmed from the calculated radiation counts and random fractions. The statistical significance of three groups was confirmed through one-way ANOVA test. On the basis of the counts of 2 minutes on normal group, the SNR of overweight group and obese group were compared. Results: The SNR were increased with loger aquisition time in 3 groups. In the condition of same acquisition time, the SNR had a statistical significance (P<0.05). The SNR were decreased to the normal, overweight, and obese, respectively. Liver activity had no significance difference on each group and RF had the significance differences (P<0.05). On the basis of the counts of 2 minutes on normal group, there were no statistical significance in a three minute acquisitions of overweight group and two minute acquisitions of obese group (P=0.150). Conclusion: In this study, the administrated amount of radiation dose did not adjust as the change of the patients weight. Increasing the acquisition time when the administration of the same amount of dose was able to get a good result of SNR. When the Based 2 minute on normal group, if overweight and obese case the increased acquisition time of 3 minute was able to obtain a similar SNR. On the basis of the normal group, the acquisition times of overweight and obese group were increased to 3 minutes per bed and the SNR were similar to the normal group.

  • PDF

Hereditary Pancreatitis - Report of a Kindred - (유전성 췌장염 - 1가계보고 -)

  • Kim, Hyoung-Ran;Chung, Jae-Hee;Song, Young-Tack;Yoon, Won-Jae;Ryu, Ji-Kon;Kim, Yong-Tae
    • Advances in pediatric surgery
    • /
    • v.12 no.1
    • /
    • pp.24-31
    • /
    • 2006
  • Hereditary pancreatitis (HP) appears as an autosomal dominant trait. If the patient has (1) more than 2 affected relatives in different generations and (2) no known etiological factors such as alcohol or gallstones, or has R122H or N29I mutation in the cationic trypsinogen (CT) gene, the diagnosis of HP can be applied. Risk of pancreatic cancer is estimated to be 53-fold higher than in a general population after the age of 50 years. We report a kindredof HP, involving three of its family together; two siblings (14 years old, 13 years old) and cousin (26 years old). The patient had complicating chronic pancreatitis and pancreatic stone, and was treated with amodified Puestow-Gillesby procedure. Her sisters showed chronic pancreatitis. Her cousin underwent a drainage procedure of the pancreatic duct for chronic pancreatitis during the high school period. All the three members showed the R122H mutation of the CT gene.

  • PDF

Solitary Hepatic VX2 Tumor Model and Its CT Findings in Rabbits (가토에서 VX2 단일간암모델과 CT 소견)

  • Lee, Hae-Beom;Lee, Ki-Chang
    • Journal of Veterinary Clinics
    • /
    • v.23 no.4
    • /
    • pp.388-392
    • /
    • 2006
  • To verify the solitary nodular hepatocellular tumor model induced by intraparenchymal VX2 tumor cell injection and assess the diagnostic imaging character by computed tomography in rabbits. The tumor cell fragment ($1{\sim}2mm^3$) was loaded in Seldinger needle and directly implanted into the livers of 80 New Zealand white rabbits. The tumor size and patterns of tumor growth were evaluated using spiral computed tomography (CT) at 1, 2, and 3 weeks after tumor implantation. A solitary nodular tumor was successfully created in 82.5% (66/80). The mortality rate was 5% (4/80). The tumor sizes measured were 7.46.3, 14.210.8, 16.212.6 cm at 1, 2, and 3 weeks after tumor implantation on arterial phase CT images. The tumors were round to oval shape with peripheral enhancement and central hypoattenuation on arterial phase, and hypoatteuated wash-out pattern on portal phase. It is considered that inoculation of tumor fragment loaded in Seldinger needle is useful and practical method for creating a solitary hepatic tumor. And CT scanning are valuable to investigate the hepatic tumor and compatible to the observations on macro-and microscopic findings.

Correlation of Hepatic $^{18}F-Fluorodeoxyglucose$ Uptake with Fatty Liver (간의 $^{18}F-Fluorodeoxyglucose$ 섭취 양상과 지방간의 관계)

  • An, Young-Sil;Yoon, Joon-Kee;Hong, Seon-Pyo;Joh, Chul-Woo;Yoon, Seok-Nam
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.5
    • /
    • pp.243-248
    • /
    • 2006
  • Purpose: Liver demonstrates heterogeneous FDG uptake and sometimes it shows abnormally increased uptake even though there is no malignant tissue. However, there was no previous study to correlate these various pattern of hepatic FDG uptake with benign liver disease. Therefore, we evaluated the significance of hepatic FDG uptake associated with various clinical factors including fatty liver, liver function tests and lipid profiles. Materials and Methods: We reviewed a total of 188 patients (male/female: 120/68, mean age: $50{\pm}9$) who underwent PET/CT for screening of malignancy. Patients with DM, impaired glucose tolerance, previous severe hepatic disease or long-term medication history were excluded. The FDG uptake in liver was analyzed semi-quantitatively using ROI on transaxial images (segment 8) and we compared mean standardized uptake value (SUV) between fatty liver and non-fatty liver group. We also evaluated the correlation between hepatic FDG uptake and various clinical factors including serum liver function test (ALT, AST), ${\gamma}-GT$, total cholesterol and triglyceride concentration. The effect of alcoholic history and body mass index on hepatic FDG uptake was analyzed within the fatty liver patients. Results: The hepatic FDG uptake of fatty liver group was significantly higher than that of non-fatty liver group. Serum total cholesterol and triglyceride concentration showed significant correlation with hepatic FDG uptake. However, there was no significant correlation between other factors (ALT, AST, and ${\gamma}-GT$) and FDG uptake. Also there was no difference of mean SUV between normal and abnormal groups on the basis of alcoholic history and body mass Index within fatty liver patients. Fatty liver and high serum triglyceride concentration were the independent factors affecting hepatic FDG uptake according to multivariate analysis. Conclusion: In conclusion, hepatic FDG uptake was strongly correlated with fatty liver and serum triglyceride concentration.

A Case of Pyogenic Liver Abscess Caused by Staphylococcus epidermidis in a Healthy Child (건강한 소아에서 발생한 Staphylococcus epidermidis에 의한 화농성 간농양 1례)

  • Gwak, Ji Hye;Eem, Yeun Joo;Choi, Ui Yoon;Kang, Jin Han
    • Pediatric Infection and Vaccine
    • /
    • v.20 no.1
    • /
    • pp.36-40
    • /
    • 2013
  • Staphylococcus epidermidis is a normal inhabitant of skin, throat, mouth, vagina, and urethra. It is not usually pathogenic, particularly in immunocompetent hosts. This report describes a case of a pyogenic liver abscess caused by Staphylococcus epidermidis in a healthy 12-year-old boy. He was admitted to Seoul St. Mary's Hospital with intermittent fever for 6 days. Findings on abdominal computed tomography (CT) showed a mass measuring $7.0{\times}6.5$ cm in the right hepatic lobe. Culture of the abscess resulted in growth of Staphylococcus epidermidis as a causative organism. The patient was successfully treated with intravenous administration of antibiotics and percutaneous drainage of the abscess.

  • PDF

Evaluation of the dose of 16-MDCT and 64-MDCT in case of Coronary Artery CT Angiography using Thermoluminescence Dosimeter (열형광선량계를 이용한 16-MDCT와 64-MDCT의 관상동맥 CT 혈관조영술 시 선량평가)

  • Kim, Sang-Tae;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.336-343
    • /
    • 2010
  • Coronary artery CT angiography has short scanning length, the exposure dose is high. Therefore, it is required to study on the organ dose when using MDCT. We compared the differences between the absorbed dose and effective dose in the major organs assessing the absorbed dose in the major organs by 16-MDCT and 64-MDCT in the subjects with coronary artery CT angiography, the same protocol by 16-MDCT and 64-MDCT. As a result, the great orders of absorbed dose when conducting coronary artery CT angiography had been shown as heart, stomach, liver, pancreas, kidney, spleen, large intestine, lung, small intestine, thyroid gland, ovary, bladder, and orbit with the absorbed dose distribution of $0.538{\pm}0.026(Mean{\pm}SD,\;p<0.05)mGy{\sim}71.316{\pm}4.316mGy$ in 16-MDCT, and heart, stomach, pancreas, spleen, liver, kidney, small intestine, large intestine, lung, thyroid gland, ovary, bladder, and orbit with the absorbed dose distribution of $0.87{\pm}0.01mGy{\sim}115.26{\pm}1.59mGy$ in 64-MDCT, demonstrating some different distributions. The exposed doses to the patient per one time scanning with coronary artery CT angiography were $71.316{\pm}4.316mGy$ in 16-MDCT as the absorbed dose based on the heart and $115.26{\pm}1.59mGy$ in 64-MDCT. The effective doses were 7.41 mSv and 12.11 mSv in 16 and 64-MDCT, respectively. Taking into account the results of brain CT with 2.8 mSv that has comparatively large scanning length and size, facial CT 0.8 mSv, chest CT 5.7 mSv, pelvic CT 7.2 mSv, and abdominal and pelvic CT 14.4 mSv, it is very high considering the scanning length of 13 cm limited to the heart for the scanning range.

Recent Research Trend in Lateral Flow Immunoassay Strip (LFIA) with Colorimetric Method for Detection of Cancer Biomarkers (암 바이오마커 검출용 비색법 기반 측면 흐름 면역 크로마토그래피 분석법(LFIA) 스트립의 최신 연구 동향)

  • Lee, Sooyoung;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.31 no.6
    • /
    • pp.585-590
    • /
    • 2020
  • Successful early diagnosis of cancer diseases such as lung, prostate, liver and adrenocortical carcinoma is a key step in determining the cost of treatment, survival rate, and cure rate. Most of current cancer diagnosis systems including biopsy, computed tomography (CT), positron emission tomography (PET)-CT, magnetic resonance imaging (MRI), ultrasonography, etc., require expensive and complicated equipment with highly trained human resources. Global medical and scientific communities have thus made numerous efforts on developing effective but rapid disease management system via introducing a wide spectrum of point-of-care medical diagnosis devices. Among them, a lateral flow immunoassay strip technique has gained a great attention due to many advantages such as cost-effectiveness, short inspection time, and user friendly accessibility. In this mini-review, we will highlight recent research trend on the development of colorimetry based LFIA strips for cancer diagnosis and discuss the future research direction and potential applications.

A Study on the Radiation Dose in Computed Tomographic Examinations (전산화단층촬영 검사의 방사선 선량에 관한 연구)

  • Lim, Chung-Hwang;Cho, Jung-Keun;Lee, Man-Koo
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.381-389
    • /
    • 2007
  • The purpose of this study is investigation of radiation dose in CT scan. Data were collected from various references and organizations. Doses measured by CT scanners of each medical organization were analyzed and they were calculated through the examination protocol. The results are as follows : 1. $CTDI_W$ value per 100mAs measured by Head Phantom was the highest in <4-slice MDCT scanner> of 24.20 mGy. $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 2. $CTDI_W$ value per 100 mAs measured using body phantom was the highest in <4-slice MDCT scanner> of 13.58 mGy and the $CTDI_W$ values were significantly different among scanner generations(p < 0.01). 3. When contrast medium was not used, the highest scanner was <16 slice MDCT> of $818.83\;mGy{\codt}cm$ in exposure dose in brain scan(p < 0.05). When the contrast medium was used, the highest scanner was <4 slice MDCT> and its average was $1,460.77\;mGy{\cdot}cm$(p < 0.1). 4. When the contrast medium was not used, the highest scanner was <16-slice MDCT> of $521.63\;mGy{\cdot}cm$ on average in terms of the exposure dose in chest inspection(p<0.05). when the contrast medium was used, the highest scanner was found in 8 slice MDCT scanner and its average was $1,174.70\;mGy{\cdot}cm$. There was no statistically significant difference among scanners. 5. When the contrast medium was not used, the highest scanner was <16-slice MDCT> and its average was $856.27\;mGy{\cdot}cm$ in exposure dose on the abdomen-pelvis(p<0.05). when the contrast medium was used, the highest scanner was <16-slice MDCT> and its average was $1,720.64\;mGy{\cdot}cm$ on average (p < 0.05). 6. When the contrast medium was not used, the highest scanner was <8-slice MDCT> and its average was $612.07\;mGy{\cdot}cm$ in exposure dose in liver inspection(p < 0.05). when the contrast medium was used, the highest scanner was <8-slice MDCT scanner> and its average was $2,197.93\;mGy{\cdot}cm$ in exposure dose(p < 0.1). seventy six point two percent of medical facilities were in risk of radiation exposure while the number of phase was three to four times in their dose inspection of contrast medium.

  • PDF

Assessment of Systemic Arterial Thromboembolism with Multi-Slice Spiral CT in a Dog (개에서 다중나선형 CT촬영에 의한 동맥혈전색전증의 평가)

  • Shin, Seung-Ho;Lee, Ki-Chang
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.208-213
    • /
    • 2007
  • A 15 kg 6-year-old intact male Jindo dog with a history of a respiratory distress, hindlimb paralysis with necrosed skin of dorsal digit for three weeks was referred to Animal Medical Center, Chonbuk National University. Heartworm infection was identified by kit examination. In plain thoracic radiographs, dilated pulmonary arteries reverse D sign and focal interstitial pattern was compatible with heartworm infection and possible pulmonary thromboembolism. Abdominal radiographs showed poor serosal detail indicating fluid accumulation within peritoneal cavity. No evidence of musculoskeletal abnormalities was found. Ultrasonography presented focal wedge-shaped hyperechogenecity on the both poles of left kidney, weak or absent pulse on the distal to the external iliac artery as well as ascites and irregular liver margin. Multi-organ failure was strongly supposed by blood profile including leukocytosis, anemia, hemoglobinuria bililubinemia, hypoalbuminemia, imbalance of electrolytes, and increased hepatic and renal function values. Interestingly, the glucose level is remarkably lower in pelvic limb compared to thoracic limb. Suspected pulmonary thromboembolism, renal infarction and femoral arterial embolization causing hindlimb paralysis and dermatic necrosis were confirmed by 3D reconstructed CT imaging. Prior to taking a consideration of euthanasia, interventional radiology was experimentally attempted but failed due to not recovered from general anesthesia. Early and accurate diagnosis of thromboembolism is valuable and 3D reconstructed CT images might be very useful to show the correct way to treat effectively.

A Case of Mesenchymal Hamartoma Associated with Biliary Atresia (담도 폐쇄증 환아에서 우연히 발견된 간엽 과오종 1례)

  • Choi, Kyung-Dan;Seo, Jeong-Kee;Shin, Eon-Woo;Ko, Jae-Sung;Kim, Woo-Sun;Park, Young-Su;Kang, Kyung-Hoon;Chi, Je-Geun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.1
    • /
    • pp.113-119
    • /
    • 2001
  • Mesenchymal hamartoma is an uncommon benign tumor usually found in childhood, especially during the first two years of life. The tumor consists of a solid component and multiple cyst. Without treatment, these lesions can grow to an enormous size. We experienced a case of mesenchymal hamartoma which was found incidentally, in a 8 month old girl who had ascending cholangitis after Kasai operation due to biliary atresia. On abdominal ultrasonography and CT, there was a well-defined homogeneous small echogenic mass in the right lobe of the liver with cirrhosis. Five months later, she underwent liver transplantation. Gross picture of the resected liver showed a dark greenish pigmented solid mass in the right lobe of the cirrhotic liver. Microscopic findings showed reactive mesenchyma and epithelial overgrowth.

  • PDF