• Title/Summary/Keyword: Liver, CT

Search Result 451, Processing Time 0.028 seconds

A Study on Matched Errors between PET and CT Images in PET/CT Examination According to Breathing Protocols (PET/CT 검사에서 호흡법에 따른 PET과 CT 영상의 정합오차)

  • Kim, Sang Un;Kwak, Dong Woo;Park, Hyeon Soo;Bang, Seong Ae;Park, Yeong Jae;LEE, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.7-10
    • /
    • 2013
  • Purpose : This study evaluated the effects of breathing protocols on matching results of PET and CT images using two breathing protocols such as free breathing and acquisition in holding the breathing after the normal expiration in acquiring CT images. Materials and Methods: Whole body FDG PET and CT images of 200 patients (mean age: 58 (range 20~84), 103 males and 97 females) using Discovery VCT (GE Healthcare, Milwaukee, USA). When taking CT images, subjects were asked to breathe freely (free breathing, n=100) or hold the breathing after the normal expiration (Hold, n=100). In the whole body image coronal section where PET and CT were matched, the matched error of the boundary between diaphragm and liver was measured in length. The matched errors were compared according to breathing protocol by age, sex and disease. The verification of statistical significance was made by SPSS 15.0 (SPSS Inc., Chicago, IL, USA) via one way ANOVA. Results: The matched error in all was 0.87 mm. According to breathing protocol, there was no significant difference in matched error as1.01 mm in free breathing and as 0.73 mm in hold breathing (p=.688). The matched error according to sex did not show significant difference as 1.08 mm of males, and 0.93 mm of females in free breathing (p=.517). In hold breathing, there was no significant difference as 0.79 mm of males and 0.66 mm of females (p=.738). There was no significant difference in matched error by age between free breathing and hold breathing (free breathing (p=.728), hold (p=.465). There was no significant difference in matched error by disease between free breathing and hold breathing (free breathing (p=.197), hold (p=.518) Conclusion: The difference in matched error between free breathing and hold breathing was less than 5 mm at 99%. There was no statistically significant difference in matched error by breathing protocol, age and disease. It was proved that there was no difference in matched error between PET and CT images according to breathing protocol during PET/CT scan.

  • PDF

A Study of Influencing Factors in the Effectiveness of Vascular and Hepatic Parenchyma Enhancement During Intravenous Injection of Contrast Medium (경정맥 조영제 주입시 혈관 및 간실질의 조영증강에 영향을 미치는 외부적 인자에 관한 연구)

  • Han Dong-Hyun;Chang Kun-Jo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.30 no.1
    • /
    • pp.131-142
    • /
    • 2004
  • In this study, when intravenous contrast medium was injected in spiral CT study, the effects of injection volume, injection rate, injection mode, location and lumen of IV catheter on enhancement of contrast medium in aorta, portal vein and liver parenchym

  • PDF

Assessment of Acquisition Protocols for Post-Radioembolization Yttrium-90 PET/CT: Initial Study (90Y SIR-Spheres를 사용한 암의 간 전이치료에서 PET 영상획득에 관한 초기연구)

  • Bahn, Young Kag;Oh, Shin Hyun;Kim, Jung Yul;Lee, Seung Jae;Park, Joon Young;Shin, Heui Soon;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.89-93
    • /
    • 2014
  • Purpose: We investigated the quantitative evaluation of PET/CT images for evaluation after treatment in the treatment of liver metastasis of cancer with $^{90}YSIR$-Sphere. Materials and Methods: Confirmed the correlation between the measured counts was expressed by setting a region of interest from the image and a measure of the dose calibrator to see a correlation diagram of an image in a PET of $^{90}Y$. A portion uptake coefficients between PET images were acquired for 20 minutes LIST mode in 15 patients treated for liver metastasis of cancer using $^{90}Y$ SIR-Spheres high, intermediate portion, a lower portion, three measuring the coefficient of the region of interest is divided into parts, we studied the conditions for proper image acquisition. Results: Coefficient of sites that set the region of interest of the PET image and the measured counts of $^{90}Yappears$ that there is a correlation diagram statistically, ($R^2=0.956$), correlation diagram from the PET image of $^{90}Yis$, PET coefficient the coefficients of all regions of interest were increased in proportion to the image acquisition time, partial ROI coefficients of the PET image is higher about 10 minutes on average, about 14 minutes on average, the central portion is lower part 19 minute average in, confirmed the equilibrium of the standard deviation. Conclusion: Using the isotope $^{90}Y$, it is suitable to obtain a PET image, to obtain the time of proper image, the evaluation of PET/CT images, using the $^{90}Y$ SIR-Spheres and that in the treatment of liver metastases of cancer, it is useful for assessing treatment.

  • PDF

Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT (PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가)

  • Moon, A-Reum;Lee, Hyuk;Kwak, In-Suk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.36-40
    • /
    • 2011
  • Purpose: $^{18}F$-FDG injected dose to the patient is quite different between the recommended dose from manufacturer and the actual dose applied to each of hospitals. injection of inappropriate $^{18}F$-FDG dose may not only increase the exposed dose to patients but also reduce the image quality. we thus evaluated the proper $^{18}F$-FDG injected dose to decrease the exposed dose to patients considering the image quality. Materials And Methods: NEMA Nu2-1994 phantom was filled with $^{18}F$-FDG increasing hot cylinder radioactivity concentration to 1, 3, 5, 7, 9 MBq/kg based on the ratio of 4:1 between the hot cylinder and background activity. after completing the transmission scan using ct, emission scan was acquired in 3D mode for 2 minutes 30 seconds/bed. ROI was set up on hot cylinder and background radioactivity region. after measuring $SUV_{max}$ those regions, then analyzed SNR at the points. clinical experiment has been conducted the object of patients who have came to smc from november 2009 to august 2010, 97 patients without having a hepatic lesions were selected. ROI was set up in the liver and thigh area. after measuring $SUV_{max}$, the image quality was compared following the injected dose. Results: in phantom study, as the injected radioactivity concentration per unit mass was 1, 3, 5, 7, 9 MBq/kg, $SUV_{max}$ was 23.1, 24.1, 24.3, 22.8, 23.6 and SNR was shown 0.48, 0.54, 0.56, 0.55, 0.55. according to increment of the injected dose, $SUV_{max}$ and SNR was increased under 5 MBq/kg but they were decreased over 7 MBq/kg. in case of clinical experiment, as increased the injected radioactivity concentration per unit mass was 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg, $SUV_{max}$ was 2.68, 2.67, 2.26, 1.88, 1.95 and SNR was shown 0.52, 0.53, 0.46, 0.46, 0.44. if the injected dose exceeds 5 MBq/kg, showed a decrease pattern as phantom study. Conclusion: increasing $^{18}F$-FDG injected dose considered patient's body weight improve image quality within a certain range. if it exceeds the range, it can be reduced image quality due to random and scatter coincidences. this study indicates that the optimal injected dose was 5 MBq/kg per unit mass the injected radioactivity concentration in 3d wb pet/ct.

  • PDF

Study on the hypochlolesterolemic and antioxidative effects of tyramine derivatives from the root bark of Lycium chenese Miller

  • Cho, Sung-Hee;Park, Eun-Jung;Kim, Eun-Ok;Choi, Sang-Won
    • Nutrition Research and Practice
    • /
    • v.5 no.5
    • /
    • pp.412-420
    • /
    • 2011
  • The aim of the present study was to investigate the hypocholesterolemic effect and potential of tyramine derivatives from Lycii Cortex Radicis (LCR), the root bark of lycium (Lycium chenese Miller) in reducing lipid peroxidation. The activities of enzymes, hepatic 3-hydroxy 3-methylglutaryl (HMG) CoA reductase and acyl-CoA:cholesterol acyltransferase (ACAT) and LDL oxidation were measured in vitro and animal experiments were also performed by feeding LCR extracts to rats. The test compounds employed for in vitro study were trans-N-p-coumaroyltyramine (CT) and trans-N-feruloyltyramine (FT), LCR components, N-(p-coumaroyl)serotonin (CS) and N-feruloylserotonin (FS) from safflower seeds, ferulic acid (FA) and 10-gingerol. It was observed that FT and FS at the concentration of 1.2 mg/mL inhibited liver microsomal HMG CoA reductase activity by ~40%, but no inhibition of activity was seen in the cases of CT, CS, FA and 10-gingerol. Whereas, ACAT activity was inhibited ~50% by FT and CT, 34-43% by FS and CS and ~80% by 10-gingerol at the concentration of 1 mg/mL. A significant delay in LDL oxidation was induced by CT, FT, and 10-gingerol. For the animal experiment, five groups of Sprague-Dawley male rats were fed high fat diets containing no test material (HF-control), 1 and 2% of LCR ethanol extract (LCR1 and LCR2), and 1% of extracts from safflower seed (Sat) and ginger (Gin). The results indicated that total cholesterol level was significantly lower in Saf, LCR2 and Gin groups, and HDL cholesterol level was lower only in Gin group when compared with HF-control group; while there was no difference in the serum triglyceride levels among the five experimental groups. The level of liver cholesterol was significantly lower in LCR1 and LCR2 groups than HF-control Serum levels of TBARS were significantly lower only in LCR2 group when compared with HF-control group. From the observed results, we concluded that LCR can be utilized as a hypocholesterolemic ingredient in combination with ginger, especially for functional foods.

Radiofrequency Ablation in Treating Colorectal Cancer Patients with Liver Metastases

  • Xu, Chuan;Huang, Xin-En;Lv, Peng-Hua;Wang, Shu-Xiang;Sun, Ling;Wang, Fu-An
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.18
    • /
    • pp.8559-8561
    • /
    • 2016
  • Purpose: To evaluate efficacy of radiofrequency ablation (RFA) in treating colorectal cancer patients with liver metastases. Methods: During January 2010 to April 2012, 56 colorectal cancer patients with liver metastases underwent RFA. CT scans were obtained one month after RFA for all patients to evaluate tumor response. (CR+PR+SD)/n was used to count the disease control rates (DCR). Survival data of 1, 2 and 3 years were obtained from follow up. Results: Patients were followed for 10 to 40 months after RFA (mean time, $25{\pm}10months$). Median survival time was 27 months. The 1, 2, 3 year survival rate were 80.4%, 71.4%, 41%, 1 % respectively. 3-year survival time for patients with CR or PR after RFA was 68.8% and 4.3% respectively, the difference was statistically significant. The number of CR, PR, SD and PD in our study was 13, 23, 11 and 9 respectively. Conclusions: RFA could be an effective method for treating colorectal cancer patients with liver metastases, and prolong survival time, especially for metastatic lesions less than or equal to 3 cm. But this result should be confirmed by randomized controlled studies.

Primitive Neuroectodermal Tumor of the Liver in a 13-year-old Boy: A Case Report (염증성 거짓 종양으로 오인된 간 내 발생한 원시신경외배엽종양)

  • Lee, Sang-Goo;Kim, Ji-Eun;Lee, Ji-Hyuk;Lee, Hye-Jin;Lee, Jong-Seung;Lee, Jee-Hyun;Choe, Yon-Ho
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.2
    • /
    • pp.214-218
    • /
    • 2008
  • Primary primitive neuroectodermal tumor (PNET) of the liver is a rare disease with aggressive behavior and poor prognosis. We report a case of a PNET of the liver in a 13-year-old boy. The patient was admitted to the hospital with fever and abdominal pain. Abdominal CT and MRI revealed a 5.5 cm sized, septated, non-enhancing mass in the hepatic hilum. The patient was initially diagnosed with an inflammatory pseudotumor. Despite 9 days of antibiotic therapy, the patient's clinical symptoms did not improve. A liver biopsy was performed in the interest of formulating a differential diagnosis. This procedure revealed tumor cells positive for CD99 on immunohistochemistry. The patient was diagnosed with a PNET.

  • PDF

A Case of Mesenchymal Hamartoma Associated with Biliary Atresia (담도 폐쇄증 환아에서 우연히 발견된 간엽 과오종 1례)

  • Choi, Kyung-Dan;Seo, Jeong-Kee;Shin, Eon-Woo;Ko, Jae-Sung;Kim, Woo-Sun;Park, Young-Su;Kang, Kyung-Hoon;Chi, Je-Geun
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.1
    • /
    • pp.113-119
    • /
    • 2001
  • Mesenchymal hamartoma is an uncommon benign tumor usually found in childhood, especially during the first two years of life. The tumor consists of a solid component and multiple cyst. Without treatment, these lesions can grow to an enormous size. We experienced a case of mesenchymal hamartoma which was found incidentally, in a 8 month old girl who had ascending cholangitis after Kasai operation due to biliary atresia. On abdominal ultrasonography and CT, there was a well-defined homogeneous small echogenic mass in the right lobe of the liver with cirrhosis. Five months later, she underwent liver transplantation. Gross picture of the resected liver showed a dark greenish pigmented solid mass in the right lobe of the cirrhotic liver. Microscopic findings showed reactive mesenchyma and epithelial overgrowth.

  • PDF

Segmental Liver Stiffness Evaluated with Magnetic Resonance Elastography Is Responsive to Endovascular Intervention in Patients with Budd-Chiari Syndrome

  • Peng Xu;Lulu Lyu;HaitaoGe;Muhammad Umair Sami;Panpan Liu;Chunfeng Hu;Kai Xu
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.773-780
    • /
    • 2019
  • Objective: To assess segmental liver stiffness (LS) with MRI before and after endovascular intervention in patients with Budd-Chiari syndrome (BCS). Materials and Methods: Twenty-three patients (13 males and 10 females; mean age, 42.6 ± 12.6 years; age range, 31-56 years) with BCS as a primary liver disease were recruited for this study. Two consecutive magnetic resonance elastography (MRE) examinations were performed before the endovascular treatment. Fifteen patients who underwent endovascular intervention treatment also had follow-up MRE scans within three days after the procedure. LS was measured in three liver segments: the right posterior, right anterior, and left medial segments. Inter-reader and inter-exam repeatability were analyzed with intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Segmental LS and clinical characteristics before and after the intervention were also compared. Results: Within three days of the endovascular intervention, all three segmental LS values decreased: LS of the right posterior segment = 7.23 ± 0.88 kPa (before) vs. 4.94 ± 0.84 kPa (after), LS of the right anterior segment = 7.30 ± 1.06 kPa (before) vs. 4.77 ± 0.85 kPa (after), and LS of the left medial segment = 7.22 ± 0.87 kPa (before) vs. 4.87 ± 0.72 kPa (after) (all p = 0.001). There was a significant correlation between LS changes and venous pressure gradient changes before and after treatments (r = 0.651, p = 0.009). The clinical manifestations of all 15 patients significantly improved after therapy. The MRE repeatability was excellent, with insignificant variations (inter-reader, ICC = 0.839-0.943: inter-examination, ICC = 0.765-0.869). Bland-Altman analysis confirmed excellent agreement (limits of agreement, 13.4-19.4%). Conclusion: Segmental LS measured by MRE is a promising repeatable quantitative biomarker for monitoring the treatment response to minimally invasive endovascular intervention in patients with BCS.

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF