• Title/Summary/Keyword: Liquid-liquid separation

Search Result 1,125, Processing Time 0.03 seconds

Effect of REM Addition on The Surface Tension and The Critical Temperature of The Immiscible Liquid Phase Separation of The 60%Bi-24%Cu-16%Sn alloy

  • Park, Joong-Chul;Min, Soon-Ki;Lee, Joon-Ho
    • Korean Journal of Materials Research
    • /
    • v.19 no.2
    • /
    • pp.111-114
    • /
    • 2009
  • For the fabrication of core-shell structure bimetallic lead-free solder balls, both the critical temperature ($T_{cr}$) for the phase separation of two immiscible liquid phases and the temperature coefficient of the interfacial tension between the two separated liquid phases are required. In order to obtain this information, the temperature dependence of the surface tension of 60%Bi-24%Cu-16%Sn(-REM) alloys was measured using the constrained drop method. The slope of the temperature dependence of the surface tension changed clearly at a critical temperature for the separation of two immiscible liquid phases. The critical temperature of the 60%Bi-24%Cu-16%Sn alloy was estimated to be 1097K. An addition of 0.05% Ce decreased the critical temperature to 1085K, whereas that of 0.05% La increased it to 1117K. It was found that the surface tension and its temperature coefficient of the 60%Bi-24%Cu-16%Sn alloy were slightly increased by the addition of 0.05% Ce and 0.05% La. In addition, additions of Ce and La increased the temperature coefficient of the interfacial tension.

Flow Characteristics of Fine Particles for Separated Device Shapes (분리장치의 형상에 따른 미립자 유동특성)

  • Hwang, Seon Kyeong;Lee, Seoung Soo;Jung, Hyo Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.544-551
    • /
    • 2013
  • Recently high speed mixer, which is mixing, grinding, dispersion for liquid-liquid material, has been widely used several industries such as food, cosmetics, pharmaceuticals, fine chemicals, electronic material. This high speed mixer has a core element part called particle separation device. Particle separation device, which makes mixed liquid and liquid material using shear forces from a rotor and a stator, is a decisive factor in the distributed parts. In this study, we examined the velocity distribution of the two models of particle separation device using computation fluid dynamics, so that we were able to see the difference of the velocity distribution according to the shape. Also, by experiment, we observed that the use of rotor-screen type is deemed more suitable in case of accurately considering the effect of improving of the dispersibility through the circulation of the future.

The Use of the Online Two-dimensional Liquid Chromatography Coupled with a Universal Detector for the Screening of Non-volatile Potential Migrants in Food Packaging Materials (식품포장재내 비휘발성 잠재 이행물질들의 스크리닝을 위한 이차원크로마토 그래피와 범용검출기의 이용)

  • Yoon, Chan-Suk;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.16 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • For screening test of the non-volatile compounds which migrate from food packaging materials into foodstuffs, the traditional high performance liquid chromatography (HPLC) systems suffer from the lack of universal detector with high sensitivity and universality and high efficiency HPLC separation column which provides complete separation of complex mixtures into all individual substances. In this work, the use possibility of online two-dimensional liquid chromatography (2D-LC) system coupled with a charged aerosol detector (CAD), a universal detector, was reviewed. 2D-LC system permits to improve peak capacity and resolving power for complex mixtures. Charged aerosol detector (CAD) offers a new feasibility for detection of any non-volatile compounds with high sensitivity and constant response factor in a calibration range. The combination of size exclusion chromatography (SEC) and normal phase HPLC (NP-HPLC) is most frequently used for the separation of the natural and synthetic polymers which are mainly used as raw materials for the manufacture of food packaging materials. However, there is no commercial software available for data acquisition and handling and therefore the quantification in 2D-LC analysis is still rare.

  • PDF

Preliminary Study on Separation of Germanium and Gallium for Development of a 68Ge/68Ga Generator

  • Lee, Heung Nae;Kim, Sang Wook;Park, Jeong Hoon;Kim, Injong;Yang, Seung Dae;Hur, Min Goo
    • Journal of Radiation Industry
    • /
    • v.5 no.2
    • /
    • pp.101-106
    • /
    • 2011
  • The separation of germanium and gallium ion with metal oxide was introduced into the development of $^{68}Ge/^{68}Ga$ generator. Germanium and gallium within mixed solution were respectively separated by using a liquid-liquid extraction and a column chromatographic method. The separation of Ge within high concentrated hydrochloric and sulfuric acid was conducted by the extraction to $CCl_4$ and the back-extraction to 0.05 M HCl. An optimum condition of the extraction by $CCl_4$ was in 5~7 M HCl and efficiency was around 80%. The gallium was selectively separated by using $Al_2O_3$ among metal oxides as sorbents from the mixed solution in 0.04~0.10 M HCl condition.

A Newly Developed Analytical and Semi-preparative Enantiomer Separation of Fluoxetine using Polysaccharide-derived Chiral Stationary Phases by High Performance Liquid Chromatography (고성능 액체 크로마토그래피에 의한 다당 유도체의 키랄 고정상에서 플록세틴의 새롭게 개발된 분석 및 반분취의 광학분리)

  • Kim, Seok Jin;Nam, Kyung Wook;Park, Bohyun;Islam, Md. Fokhrul;Lee, Wonjae
    • KSBB Journal
    • /
    • v.31 no.3
    • /
    • pp.186-191
    • /
    • 2016
  • A liquid chromatographic method for the enantiomer separation of fluoxetine was performed using covalently bonded and coated type polysaccharide-derived chiral stationary phases (CSPs). The degree of enantioseparation is affected by the used CSPs and mobile phases. The performance of Chiralpak IC was superior to the other CSPs used in this study. Out of various solvent composition and additives, the greatest separation and resolution was observed using Chiralpak IC with mobile phase of 2-propanol in hexane with diethylamine as an additive. Semi-preparative separation of fluoxetine was performed on the analytical Chiralpak IC column to obtain (R)- and (S)-fluoxetine enantiomer with high chemical and optical purity. From the overall study, the developed liquid chromatographic method on polysaccharide-derived CSPs is expected to be very useful for the enantiomer separation of fluoxetine.

Experimental Study of Characteristics on Double Heat Exchange Pipe Used Separation Type Air-Conditioner (분리형 에어컨용 2중 열교환 배관 특성에 관한 실험적 연구)

  • Kim, J.D.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.31-37
    • /
    • 2006
  • In this study, the ability for the function of double pipe inserted liquid pipe with small diameter in the gas pipe with large diameter for the circulating of liquid of high temperature and high pressure and low temperature and low pressure at the same time is presented. And in this double pipe, liquid pipe of high temperature and pressure is used to connect condenser and expansion valve and gas pipe of low temperature is used to connect evaporator and compressor. Also, when liquid refrigerant of high temperature and gas refrigerant of low temperature is circulated by reversed flow in the double pipe. The contribution of liquid gas heat exchange pipe is studied by comparison of the effect of heat transfer by temperature difference when liquid pipe and gas pipe is installed separately.

  • PDF

A Study of the Performance Improvement of a Centrifugal Separator for Gas-Liquid Two-Phase Flow (기액이상류 원심분리기의 성능개선에 관한 연구)

  • Kim, Jin-Man;Lee, Jun-Hee;Yoon, Yong-Kwan;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3215-3220
    • /
    • 2007
  • Gas-liquid separator has been designed for the sake of reducing expenses associated with production operations. To date, a number of gas-liquid separators have been installed and put to use for various applications. Despite the advantages of simple and compact configuration of separator with no moving part, its efficient operation is limited in terms of total pressure losses, separation performance and flow-induced noise and vibration, which are closely associated with the very complicated flow phenomena involved. In the present study, a gas-liquid centrifugal separator with a swirl vane is investigated for the purpose of water separation from compressed moisture air. The 3D Navier-Stokes equations are numerically solved using a fully implicit finite volume scheme. Based upon the obtained solutions, tangential velocities, centrifugal forces, vortices and total pressure losses are analyzed to find out the best design parameters. From the present study, several attempts are made to improve the performance of conventional separators of centrifugal type.

  • PDF

Development of Heat Pump Use Slurry Pig Manure Evaporation Drying System (열펌프를 이용한 슬러리 돈분뇨 증발건조처리시스템 개발)

  • Kim H. T.;Choi H. L.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.32-37
    • /
    • 2005
  • This study was conducted the slurry pig manure treatment by condensation drying of liquid from the slurry manure with a heat-pump and electric heater combined with air flow channel system. The system was designed as liquid and solid matters separation of slurry manure, and it can doing continuous input of slurry manure from a pig house, and it can operated year round use for pig farms. The separation of liquid and solid matters from slurry manure needed the prevention of solid accumulation in the system. The system was designed as closed space from outside air space for maximized evaporation of liquid and the condensation of liquid from slurry manure. The system can be operated the pig slurry manure treatment regardless of seasons in a yew. The separated evaporation water from the pig slurry manure by the heat-pump was satisfactorily pure water that can be used as washing water in livestock farms. The system can applicate to about 100 heads of pig, and the proper area of evaporation plate system was considered around $10\;m^2$. The input electrical energy of about 15 kWh which the cost equal to 250,000 won per month.

Enhanced Adhesion and Transmittance Uniformity in Laminated Polymer-Dispersed Liquid Crystal Films

  • Yoo, Seong-Hyeon;Park, Min-Kyu;Park, Ji-Sub;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.753-761
    • /
    • 2014
  • We propose a two-step UV irradiation procedure to fabricate polymer-dispersed liquid crystal (PDLC) films by lamination. During the first UV treatment, before lamination, the UV-curable monomers coated on one film substrate are solidified through photo-polymerization as the phase separation between the liquid crystals and the monomers. Introducing an adhesion-enhancement layer on the other plastic substrate and controlling the UV irradiation conditions ensure that UV-induced cross-linkable functional groups remain on the surfaces of the photo-polymerized layers. Thereby, the adhesion stability between the top and bottom films is much improved during a second (post-lamination) UV treatment by further UV-induced cross-linking at the interface. Because the adhesion-enhancement and PDLC layers prepared by the bar-coating process are solidified before lamination, the PDLC droplet distribution and the cell gap between the two plastic substrates remain uniform under the lamination pressure. This ensures that the voltage-controlled light transmittance is uniform across the entire sample.

Effect of 50 ㎛ class granules on the Injection Behavior of Brushite Bone Cement Prepared via Pre-dissolution Route

  • Mun, Da Hye;Lee, Sang Cheon;Oh, Kyung-Sik
    • Journal of Powder Materials
    • /
    • v.27 no.6
    • /
    • pp.468-476
    • /
    • 2020
  • The bone cement used for vertebroplasty must be sufficiently injectable. The introduction of granules reduces the amount of liquid required for liquefaction, implying that higher fluidity is achieved with the same amount of liquid. By employing β-tricalcium phosphate granules with an average diameter of 50 ㎛, changes in injectability are observed based on the paste preparation route and granular fraction. To obtain acceptable injectability, phase separation must be suppressed during injection, and sufficient capillary pressure to combine powder and liquid must work evenly throughout the paste. To achieve this, the granules should be evenly distributed. Reduced injection rates are observed for dry mixing and excessive granular content, owing to phase separation. All these correspond to conditions under which the clustered granules weakened the capillary pressure. The injected ratio of the paste formed by wet mixing displayed an inverted U-type shift with the granular fraction. The mixture of granules and powder resulted in an increase in the solid volume fraction, and a decrease in the liquid limit. This resulted in the enhancement of the liquidity, owing to the added liquid. It is inferred that the addition of granules improves the injectability, provided that the capillary pressure in the paste is maintained.