• 제목/요약/키워드: Liquid transfer

검색결과 1,332건 처리시간 0.023초

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권2호
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

실험실적 규모의 분무흡수건조반응기의 배출가스 중 아황산가스 처리성능 연구 (Flue Gas Sulfur Dioxide Removal Performance of a Bench-Scale Spray Absorption/Drying Reactor)

  • 동종인;구우회;임대현
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.449-457
    • /
    • 1996
  • The main purpose of this study was to investigate sulfur dioxide removal performance of flue gas desulfurization system utilizing a Spray Absorption/Drying Reactor. In this system, the size of droplets was considered the most significant factor and tested using a PDA system. Lime slurry flow rate, operating temperature, calcium/sulfur (Ca/S) ratio and applied air pressure were selected as major operation variables and tested/analyzed in terms of system performance. The results are as follows. 1. The $SO_2$ removal efficiencies were 49%, 74%, 85% for Ca$(OH)_2$ slurry flow rate of 10, 20, 30 ml/min, which implies that the increase of slurry flow rate improves removal efficiency. The optimum slurry flow rate in this study was, however, considered 20 ml/min because of constraints of system troubles and absorbent utilization. 2. As Ca/S ratio increased, $SO_2$ removal efficiency was observed to increase. 3. As air pressure, at the atomizing nozzole, increased from 3 to 5 $kg/cm^2, SO_2$ removal efficiency increased from 74% to 80%, because of droplet size reduction due to pressure increase during atomizing process and the increase of surface area, helping mass transfer between gas and liquid phase.

  • PDF

변형 Roebuck 압축기를 이용한 J-T 네온 냉각시스템의 열역학적 설계 (Thermodynamic Design of J-T Neon Refrigeration System Utilizing Modified Roebuck Compression Device)

  • 정제헌;정상권
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.432-438
    • /
    • 2003
  • This paper describes a modified Roebuck compression device as a potential compression device of a rotating cryogenic refrigeration system in superconducting machine such as generator or motor. The conventional cryogen transfer method from stationary refrigeration system to rotating system can be eliminated by an on-board cryogenic refrigeration system that utilizes well-designed multi-stage modified Roebuck compression device. This paper shows basic thermodynamic analysis of modified Roebuck compression device and its application for compressing neon at 77 K with substantial pressure ratio when the rotor diameter is 0.8 m with rotating speed of 3600 rpm. The device does not require any moving part in rotating frame, but two separate thermal reservoirs to convert thermal energy into mechanical compression work. The high temperature thermal reservoir is atmospheric environment at 300 K and the low temperature thermal reservoir is assumed as a liquid nitrogen bath at 77 K. The concept of the compression device in this paper demonstrates its usefulness of generating high-pressure neon at 77 K for rotating J-T neon refrigeration cycle of superconducting rotor.

전기부상공정에서 촉매성 산화물 전극에 따른 기포 발생량과 크기에 관한 연구 (Study on Bubble Generation and Size by Dimensionally Stable Anode in Electroflotation Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제16권10호
    • /
    • pp.1189-1195
    • /
    • 2007
  • Small gas bubbles are used in many environmental and industrial processes for solid-liquid separations or to facilitate heat and mass transfer between phases. This study examines some of the factors that affect the bubble volume and size processed in the EF (electroflotation) process. The effect of electrode material, NaCl dosage, current and electrode distance were studied. The results showed that the generated bubble volume with electrode material lay in: Pt/Ti ${\fallingdotseq}$ Ru/Ti ${\fallingdotseq}$ Ir/Ti > Ti electrode. The more NaCl dosage was high, the smaller bubble was generated due to the low electric power. Bubble generation was increased with increase of current. With the increase of NaCl dosage, bubble generation was increased at same electric power (16.2 W). Generated bubble volume was not affected by electrode distance. However, no clear trends in bubble size as a function of these parameters were evident.

Manufacturing and Temperature Measurements of a Sodium Heat Pipe

  • 이병인;이성홍
    • Journal of Mechanical Science and Technology
    • /
    • 제15권11호
    • /
    • pp.1533-1540
    • /
    • 2001
  • A high-temperature sodium stainless steel heat pipe was fabricated and its performance has been investigated. The working fluid was sodium and it was sealed inside a straight tube container made of stainless steel. The amount of sodium occupied approximately 20% of the total volume of the heat pipe and its weight was 65.7gram. The length of a stainless steel container is 1002mm and its outside diameter is 25.4mm. Performance tests were carried out in a room air condition under a free convective environment and the measured temperatures are presented. The start-up behavior of the heat pipe from a frozen state was investigated for various heat input values between 600W and 1205W. In steady state, axial temperature distributions of a heat pipe were measured and its heat transfer rates were estimated in the range of vapor temperature from 50$0^{\circ}C$ to 63$0^{\circ}C$. It is found that there are small temperature differences in the vapor core along the axial direction of a sodium heat pipe for the high operating temperatures. But for the range of low operating temperatures there are large temperature drops along the vapor core region of a sodium heat pipe, because a small vapor pressure drop makes a large temperature drop. The transition temperature was reached more rapidly in the cases of high heat input rate for the sodium heat pipe.

  • PDF

인간형 로봇 내부의 다중 열원에 대한 수냉식 냉각판의 성능 (Performance of Liquid-Cooled Cold Plates for Multiple Heat Sources in a Humanoid Robot)

  • 강상우;김서영;문종민;황규대;리광훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2053-2058
    • /
    • 2008
  • It was investigated thermal performances on two array types of a serial circulation and a two-way parallel circulation for six water-cooled cold plates covered with non-metallic material (polycarbonate, PC) to reduce weight of the cooling devices for humanoid robot cooling. Six cold plates attached on $10{\times}10\;mm^2$ copper base : $0.5{\times}0.5\;mm^2$ pin-finned surfaces of 1.5 mm high with 0.5 mm array spacing, was mounted on six copper heating blocks with isothermal conditions of $50{\sim}90^{\circ}C$, respectively. In order to compare thermal characteristics according to two circulation types, the surface temperatures of heating blocks and the cooling water temperatures at inlets and outlets of cold plates were measured. From the results, it was found that a two-way parallel circulation was better performance than a serial circulation in terms of total thermal resistance, total heat transfer rate, and surface temperature rises from $1^{st}$ heating block to last one for six multiple cold plates.

  • PDF

Micropropagation of Plants and Mass Production of Adventitious Roots from Culture of Seedling Explants of Polygonatum odoratum

  • Yoon, Eui-Soo
    • 한국자원식물학회지
    • /
    • 제11권
    • /
    • pp.40-47
    • /
    • 1998
  • When the leaves, roots and stem segments of seedling of Polygonatum odoratum were cultured on Murashige and Skoog medium with 2.0mg/l BAP, stem segments were the most efficient explants for adventitious shoot inductino. To observe the efficient combination of growth regulators on the adventitious shoot formation , stem segments were cultured on MS medium with various kinds of cytokinins (BAP, kinetin, zeatin). From this experiment, cytokinin treatement was prerequisite for theadventitious shoot formatino,especially BAP was the most effective. Auxin (NAA or IBA) in combination with cyotokinin highly enhanced the adventitious shoot formation. Twenty five percents of explants produced the adventitious shoots on medium with 2.0mg/l BAP solely, while 83% of explants produced the adventitious shoots on medium with 2.0mg/l BAP and 0.1mg/l IBA. Root formationform adventitious shoot was promoted after transfer to 1/2 MS medium supplemented with 0.1mg/l IBA and 0.5mg/l zeatin, thereafter the plantlets with shoots and roots were cultured on 1/2MS medium lacking growth regulators. When the stem segments were cultured to MS medium with 1.0mg/l 2,4 NAA and IBA , yellow and nodulous cali were formed from the stem segments which were developed into adventitious roots. These roots were actively grew after transferred to MS liquid medium lacking growth regulators.

  • PDF

고온균(高溫菌)의 tryptophanase에 관한 연구 -indole 생성균(生成菌)의 분리(分離) (Studies on the Tryptophanase of Thermophilic Bacteria -Part I. Screening of Indole-Forming Thermophile)

  • 오만진;김찬조
    • 농업과학연구
    • /
    • 제7권1호
    • /
    • pp.44-51
    • /
    • 1980
  • 고온균(高溫菌) tryptophanase을 분리하기 위하여 tryptophan이 함유된 액체배지에 화산토양(火山土壤), 온천수(溫泉水)를 비롯한 각 지역의 토양(土壤)과 퇴비(堆肥) 등의 분리원(分離源)을 접종(接種)하고 $60^{\circ}C$에서 집적배양(集積培養)한 결과 indole 생성원수(生成園數)의 변화는 다음과 같다. 집적배양(集積培養) 중에 Penicilin G 10r와 Chloramphenicol 10r의 첨가로 집적배양액(集積培養液) ml 당(當) indole 생성원(生成園)의 수(數)는 $10^3cells/ml$, $10^7cells/ml$으로 농축(濃縮)이 가능하였다. indole 생성원(生成園)은 고체배지상에 생육이 되지 아니하였음으로 순수분리(純粹分離)를 위하여서는 액체배지를 이용한 분리 방법 등의 검토가 요망되었다.

  • PDF

Volume-Junction Method를 이용한 우주왕복선 액체로켓엔진 열교환기 모델링 (Modeling of Space Shuttle Main Engine heat exchanger using Volume-Junction Method)

  • 차지형;고상호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.213-217
    • /
    • 2017
  • 액체로켓엔진 고장에서 시동과정이 30% 이상을 차지하며 특히, 우주왕복선 주 엔진(Space Shuttel Main Engine, SSME)은 2%의 밸브위치 오차 또는 0.1초의 시간오차와 같은 작은 변화에도 급격하게 변화하는 매우 민감한 시스템으로 시동과정의 모델링이 중요하다. 하지만, 시동과정에서 비선형 질량 유량과 열전달 특성 때문에 많은 어려움이 발생한다. 본 논문에서는 이를 해결하기 위하여 부분적인 전산유체해석(Computational Fluid Dynamics, CFD) 방법을 사용하였으며 본 논문에서는 구성품의 모델링을 수행하여 정상상태에서 확인을 하였다.

  • PDF

LINEAR INSTABILITY ANALYSIS OF A WATER SHEET TRAILING FROM A WET SPACER GRID IN A ROD BUNDLE

  • Kang, Han-Ok;Cheung, Fan-Bill
    • Nuclear Engineering and Technology
    • /
    • 제45권7호
    • /
    • pp.895-910
    • /
    • 2013
  • The reflood test data from the rod bundle heat transfer (RBHT) test facility showed that the grids in the upper portion of the rod bundle could become wet well before the arrival of the quench front and that the sizes of liquid droplets downstream of a wet grid could not be predicted by the droplet breakup models for a dry grid. To investigate the water droplet generation from a wet grid spacer, a viscous linear temporal instability model of the water sheet issuing from the trailing edge of the grid with the surrounding steam up-flow is developed in this study. The Orr-Sommerfeld equations along with appropriate boundary conditions for the flow are solved using Chebyshev series expansions and the Tau-Galerkin projection method. The effects of several physical parameters on the water sheet oscillation are studied by determining the variation of the temporal growth rate with the wavenumber. It is found that a larger relative steam velocity to water velocity has a tendency to destabilize the water sheet with increased dynamic pressure. On the other hand, a larger ratio of steam boundary layer to the half water sheet thickness has a stabilizing effect on the water sheet oscillation. Droplet diameters downstream of the spacer grid predicted by the present model are found to compare reasonably well with the data obtained at the RBHT test facility as well as with other data recently reported in the literature.