DOI QR코드

DOI QR Code

Study on Bubble Generation and Size by Dimensionally Stable Anode in Electroflotation Process

전기부상공정에서 촉매성 산화물 전극에 따른 기포 발생량과 크기에 관한 연구

  • Published : 2007.10.31

Abstract

Small gas bubbles are used in many environmental and industrial processes for solid-liquid separations or to facilitate heat and mass transfer between phases. This study examines some of the factors that affect the bubble volume and size processed in the EF (electroflotation) process. The effect of electrode material, NaCl dosage, current and electrode distance were studied. The results showed that the generated bubble volume with electrode material lay in: Pt/Ti ${\fallingdotseq}$ Ru/Ti ${\fallingdotseq}$ Ir/Ti > Ti electrode. The more NaCl dosage was high, the smaller bubble was generated due to the low electric power. Bubble generation was increased with increase of current. With the increase of NaCl dosage, bubble generation was increased at same electric power (16.2 W). Generated bubble volume was not affected by electrode distance. However, no clear trends in bubble size as a function of these parameters were evident.

Keywords

References

  1. 한무영,신민석,2002,회분식 전해부상법(EF)에서 극판 재질이 탁도의 제거효율에 미치는 영향,상하수도학회지,16(1),87-92
  2. 김원태,2001,전해부상법에서 미세기포와 입자의 기초특성 연구를 통한 제거 메커니즘 연구,석사학위논문,지구환경시스템공학부,서울대학교,서울
  3. 박용호,한무영,안현주,허창원,2003,전해부상법에 의한 슬러지 농축특성,대한환경공학회 춘계학술발표회 논문집,271-274
  4. 윤창곤,2005,전해부상을 이용한 하수슬러지 고액분리의 최적화,석사학위논문,토목환경공학과,성균관대학교,서울
  5. American Water Works Association,1999,Water quality and treatment 5th ed., McGraw Hill Inc.,278-290pp
  6. 이준,2004,부상공정에 의한 상수슬러지 농축,석사학위논문,지구환경시스템공학부,서울대학교,서울
  7. Hosny, A. Y., 1996, Separating oil from oil-water emulsions by electro-flotation technique, Sepa. Tech., 6, 9-17 https://doi.org/10.1016/0956-9618(95)00136-0
  8. 박영식, 2007, 전기부상을 이용한 하수슬러지 농축기술개발, 산학협동재단(재) 최종보고서, 40-43pp
  9. 신민석, 2002, 전해부상법에서 금속이온이 기포의 제타전위에 미치는 영향, 석사학위논문, 지구환경시스템공학부, 서울대학교, 서울
  10. Gao, P., Chen, X., Chen, F., and Chen, G., 2005, Removal of chromium(VI) from wastewater by combined electrocoagulation-electroflotation without a filter, Sepa, and Puri. Tech., 43, 117-123 https://doi.org/10.1016/j.seppur.2004.10.008
  11. Moulai, N., and Tir, M., 2004, Coupling flotation with electroflotation for waste oil/water emulsion treatment. optimization of the operating conditions, Desalination, 161, 115-121 https://doi.org/10.1016/S0011-9164(04)90047-1
  12. 신민석, 이광형, 김단중, 한무영, 2001, 전해부상법에 의한 축산폐수의 처리 특성, 상하수도학회지, 15(5), 379-384
  13. 김동석, 박영식, 2007, 불용성 전극을 이용한 Rhodamine B의 전기화학적 탈색, 한국물환경학회지, 23(3), 377-384
  14. Bailey, J. E., Ollis, D. F., 1986, Biochemical engineering fundamentals, 2nd ed., McGrowHill Inc., 480-485pp
  15. 한무영, 박용효, 이준, 2001, 전해부상에서 미세기포의 크기특성, 대한상하수도학회한국물환경학회 공동추계학술발표회 논문집, 297-280
  16. 박용효, 한무영, 2002, 전해부상에서 전압과 극판 재질에 따른 미세기포의 크기 특성, 상하수도학회지, 16(6), 663-669
  17. 조강우, 김윤중, 정태학, 2006, 전해부상을 이용한 활성슬러지의 부상 특성에 관한 연구, 한국물환경학회대한상하수도학회 공동춘계학술발표회 논문집, 173-180
  18. Chen, G., 2004, Electrochemical technologies in wastewater treatment, Sepa. and Puri. Tech., 38, 11-41 https://doi.org/10.1016/j.seppur.2003.10.006

Cited by

  1. Removal of Freshwater Microalgae by Flocculation-Enhanced Electro-flotation Using Stainless Steel Mesh Electrode pp.2191-4281, 2018, https://doi.org/10.1007/s13369-017-2712-y