• Title/Summary/Keyword: Liquid sodium

Search Result 523, Processing Time 0.028 seconds

Use of Salimeters and Sodium Reduction Education in School Foodservice in the Gyeonggi Area (경기지역 학교급식의 염도계 사용과 나트륨 저감화 교육실태)

  • Lee, Kyoungsook
    • Journal of the Korean Dietetic Association
    • /
    • v.19 no.2
    • /
    • pp.173-181
    • /
    • 2013
  • This study used survey data to identify the use of salimeters and the prevalence of sodium reduction education in the Gyeonggi region. A survey with 211 dietitians working in school foodservice (106 in elementary schools, 69 in middle schools, and 36 in high schools) was conducted from August 6 to August 17, 2012. The data were analyzed using the SPSS program. Though 86.6% of school kitchens had salimeters, the rate for checking the sodium content of soup or stew was just 62.7% and the rate for checking the sodium content of kimchi and solid food was very low. Since salimeters are mostly used to measure sodium in liquid foods, it is urgent to provide an education and manual on using salimeters and to promote salimetry for kimchi and side dishes. It is also important to provide students with nutritional information by clearly posting the sodium content of food on menus and compelling students to notice them. Sodium reduction education for cooks was conducted in the 70.3% of the kitchens; however, the dietitians perceived that the cooks did not understand the importance of the education. Also, sodium reduction education for students was mostly provided through indirect methods, rather than face-to-face education, resulting in poor educational data (only 36.4% comprehending). By providing detailed guidelines for sodium reduction and labelling accurate content of sodium of the menus, we will be able to enforce practices for sodium reduction in school lunches.

VALIDATION OF A DESIGN CODE FOR SODIUM-TO-SODIUM HEAT EXCHANGERS BY UTILIZING COMPUTATIONAL FLUID DYNAMICS (전산유체역학을 이용한 소듐-소듐 열교환기 설계코드의 검증)

  • Kim, D.;Eoh, J.H.;Lee, T.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.1
    • /
    • pp.19-29
    • /
    • 2016
  • A Prototype Gen-IV Sodium-cooled Fast Reactor which is one of the $4^{th}$ generation nuclear reactors is in development by Korea Atomic Energy Research Institute. The reactor is composed of four main fluid systems which are categorized by its functions, i.e., Primary Heat Transport System, Intermediate Heat Transport System, Decay Heat Removal System and Sodium-Water Reaction Pressure Relief System. The coolant of the reactor is liquid sodium and sodium-to-sodium heat exchangers are installed at the interfaces between two fluid systems, Intermediate Heat Exchangers between the Primary Heat Transport System and the Intermediate Heat Transport System and Decay Heat Exchangers between the Primary Heat Transport System and the Decay Heat Removal System. For the design and performance analysis of the Intermediate Heat Exchanger and the Decay Heat Exchanger, a computer code was written during previous step of research. In this work, the computer code named "SHXSA" has been validated preliminarily by computational fluid dynamics simulations.

Plugging and Re-opening Phenomena of the 5Cr-1Mo Steel Leak Hole by Water Leakage in Sodium Atmosphere (소듐 분위기에서 물누출에 의한 5Cr-1Mo Ferrite강 구멍의 막힘과 재개방 현상)

  • Jeong, Kyung-Chai;Kim, Tae-Joon;Choi, Jong-Hyeun;Park, Jin-Ho;Hwang, Sung-Tai
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.674-679
    • /
    • 1998
  • Small water leak experiment was carried out in liquid sodium atmosphere using a specimen of ferrite steel, which will be expected to be a material of the heat transfer tube of liquid metal fast breeder reactor. Self-plugging phenomena of leak path could be explained by the products of reaction and corrosion by sodium-water reaction. Also, re-opening mechanism of self-plugged path could be explained by the thermal transient and vibration of heat transfer tube. As a result, perfect re-opening time of self-plugged leak path was observed to be 129 minutes after water leak initiation. Re-opening shape of a specimen was appeared with double layer of circular type, and re-opening size of this specimen surface was about 2 mm diameter on sodium side.

  • PDF

Antimicrobial Effect of Buffered Sodium Citrate (BSC) on Foodborne Pathogens in Liquid Media and Ground Beef

  • Ryu, Si-Hyun;Fung, Daniel -Y. C.
    • Preventive Nutrition and Food Science
    • /
    • v.15 no.3
    • /
    • pp.239-243
    • /
    • 2010
  • The antimicrobial effects of a commercially available, buffered sodium citrate (BSC) were evaluated for the reduction of total aerobic bacteria count, Salmonella Typhimurium, Escherichia coli O157:H7, Listeria monocytogenes and Staphylococcus aureus in a liquid medium and ground beef. BSC at 0, 1, 2 and 4.8% (wt/vol) or 0, 3, and 4.8% (wt/wt) was mixed into inoculated brain heart infusion (BHI) broth and ground beef (80% lean), respectively. BSC at concentrations of 1 and 2% did not inhibit growth of the pathogens tested in BHI broth. E. coli O157:H7 in BHI broth with 4.8% BSC was significantly reduced (p<0.05) by 3~4 log CFU/mL compared with the control for up to 4 days. At 4.8%, BSC treatment of ground beef most significantly reduced (p<0.05) total aerobic count and E. coli O157:H7 by 2.1 and 2.0 log CFU/g, respectively. This study indicates that the legally allowable level of 1.3% (wt/wt) BSC is not effective for reducing the pathogens tested in ground beef stored at $7^{\circ}C$.

Validations of Analysis Methods for Decursin and Decursinol Angelate of Angelicae gigantis Radix by Reversed-Phase Liquid Chromatography

  • Lee, Jong-Pill;Chang, Seung-Yeup;Park, Sang-Yong
    • Natural Product Sciences
    • /
    • v.10 no.6
    • /
    • pp.262-267
    • /
    • 2004
  • A reversed-phase liquid chromatographic method for decursin and decursinol angelate of Angelicae gigantis Radix, an important crude drug in Korean traditional medicine, was developed and validated. Decursin and decursinol angelate, the structure isomer (pyranocoumarin) each other, are the main organic constituents in Angelicae gigantis Radix. This method was developed using a RP-18 column, UV detector at 280 nm and 50% acetonitrile solution containing 0.01 M sodium dodecyl sulfate and 25 mM sodium dihydrogen phosphate (pH 5.0) as the mobile phase. Various validation parameters were included and evaluated satisfactorily. Linearity was established in range 2-75 mg/ml of decursin and decursinol angelate (correlation coefficient = 0.9997 and 0.9995, respectively). This analytical method showed good accuracy (98.1% and 99.5%, respectively). Precision (repeatability) revealed a relative standard deviation value of 1.71% (decursin) and 3.19% (decursinol angelate). For intermediate precision measure the considered variables were equipment and days. A robustness test showing the influence of deferent counter-ion concentration in mobile phase was also performed.

Advantages of Acoustic Leak Detection System Development for KALIMER Steam Generators

  • Kim, Tae-Joon;Valery S. Yughay;Hwang, Sung-Tai;Chai, Jeong-Kyung;Choi, Jong-Hyeun
    • Nuclear Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.423-440
    • /
    • 2001
  • For sodium cooling liquid metal reactors during the last 25 years, it was most important to verify the safety of the steam generator, which absolutely requires a water leak detection system with fine sensitivity and response. This study describes the structure and leak classification of the HAMMER (Korea Advanced Liquid Metal Reactor) steam generator, compared with other classifications, and explains the effects of leak development. The requirements and experimental situations for the development of the KALIMER acoustic leak detection system (KADS) which detects micro leaks, not intermediate leaks, are introduced. We proposed four frequency bands, 1∼8kHz, 8∼20kHz, 20∼40kHz and 40∼200kHz, split effectively for analyzing the detected acoustic leak signals obtained from the sodium-water reaction model or water model in the mock-up system.

  • PDF

Analysis of Methoxyfenozide and Bentazone in Plant with HPLC by pH-Adjusted Liquid-liquid Partition Cleanup (pH조절 분배추출에 의한 식물체 중 Methoxyfenozide와 Bentazone의 HPLC 분석)

  • Lo, Seog-Cho;Hwang, Cheol-Hwan;Yoo, Ki-Yong;Han, Seong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.3
    • /
    • pp.246-253
    • /
    • 2007
  • This study was performed to enhance the cleanup efficiency of methoxyfenozide and bentazone by pH adjustment in the course of liquid-liquid partition and to develop an optimum analytical conditions using HPLC coupled with DAD for two matrices, brown rice and rice straw. Preparation procedure of brown rice sample was "extraction${\rightarrow}$coagulation${\rightarrow}$liquid-liquid partition$\rightarrow$-florisil C.C", and this procedure was samely applied to two compounds. In rice straw, preparation procedure of methoxyfenozide sample was "extraction$\rightarrow$-alkalization$\rightarrow$liquid-liquid extraction$\rightarrow$coagulation$\rightarrow$florisil C.C", and in the case of bentazone, "extraction$\rightarrow$alkalization$\rightarrow$liquid-liquid partition$\rightarrow$acidification$\rightarrow$liquid-liquid extraction$\rightarrow$florisil C.C". All these purified samples were redissolved in the mobile phases, acetonitile : 20 mM sodium acetate (75:25, v/v) for methoxyfenozide and acetonitrile : 75 mM sodium acetate, pH 6.0 (40:60, v/v) for bentazone. Recoveries of methoxyfenozide analysis in brown rice and rice straw were 83.5-97.4 and 86.4-97.3%, and detection limits were 0.02 and 0.04 mg/kg, respectively. Recoveries of bentazone in brown rice and rice straw were 86.8-101.9 and 88.3-94.5% and detection limits were 0.005 and 0.01 mg/kg, respectively. This methods seem to be usefully applied to the residue analysis of two compounds in the view of producing stable analytical condition and fair reproducibility.

Long-Term Life Test of A Stainless Steel-Sodium Heat Pipe (스테인리스 스틸-나트륨 히트파이프의 장기 수명 시험)

  • Park, S.Y.;Jung, E.G.;Boo, J.H.;Kang, H.K.;Yoo, J.H.;Park, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1058-1062
    • /
    • 2004
  • High-temperature cylindrical stainless steel/sodium heat pipe was manufactured and tested under long-term operation. The container material was stainless steel 316L and the working fluid was sodium. The heat pipe was 25.4 mm in diameter and 1000 mm in length with a two-layer screen mesh wick. The evaporator part was 600 mm and the condenser part was 300 mm in length. Total measurement points on heat pipe were 15 points and 12 points were located in condenser part. The heat pipe was heated for 142 days(3400 hours) at $800^{\circ}C$. In the test period, the maximum temperature difference was increased from $18^{\circ}C$ o $28^{\circ}C$ and the maximum thermal resistance was as low as $0.015^{\circ}CW$.

  • PDF

Evaporation Characteristics of a Water Droplet Containing Sodium Acetate Trihydrate as an Additive (첨가제로 아세트산 나트륨-3수화물을 함유한 물 액적의 증발 특성)

  • Park, Jae-Man;Shin, Chang-Sub
    • Journal of the Korean Society of Safety
    • /
    • v.19 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • The evaporation phenomena of waterr droplet which has sodium acetate trihydrate($CH_3COONa{\cdot}3H_2O$) as a fire suppression additive were studied. Solutions of sodium salt up to 50% and heated stainless-steel surface were used in the experiment. The evaporation process was recorded using a charge-coupled-device camera at 120 frames per second. The average evaporation rate of the sodium acetate trihydrate soluation was lower than that of pure water at a given surface temperature and decreased with the concentration increase due to the precipitation of salt in the liquid film and change of surface tension. The variation of liquied film diameter was measured by time and it was increased by the hot surface temperature increase.

Analysis of Sodium Spray Fire Using Gaussian Droplet Size Distribution (Gaussian 액적 크기 분포 함수를 이용한 분무형 화재 현상 해석)

  • Kim, B.H.;Hahn, D.H.;Suh, S.H.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.1
    • /
    • pp.72-81
    • /
    • 2004
  • Study on the analysis of sodium spray fire using Gaussian drop size distribution, which redistributes a droplet spectrum with given mean diameter if its size classes with critical diameter(D>8mm) occur, was carried out. In this case, the oversized droplets were reduced to a stable diameter. Results calculated by the code using Gaussian drop size distribution were in better agreement with AI experimental results than those of NACOM and SPRAY code. The effect of variance on pressure in the test cell appeared greatly by introducing Gaussian function, which could represent various sodium droplet size distribution. The increase of the variance with mean droplet size resulted had an important effect upon the pressure in the test cell.