• 제목/요약/키워드: Liquid in a tank

검색결과 453건 처리시간 0.029초

Self-healing and leakage performance of cracks in the wall of a reinforced concrete water tank

  • Gao, Lin;Wang, Mingzhen;Guo, Endong;Sun, Yazhen
    • Earthquakes and Structures
    • /
    • 제16권6호
    • /
    • pp.727-741
    • /
    • 2019
  • A reinforced concrete water tank is a typical functional liquid storage structure and cracks are the greatest threat to the liquid storage structure. Tanks are readily cracked due to seismic activity, thereby leading to the leakage of the stored liquid and a loss of function. In order to study the effect of cracks on liquid storage tanks, self-healing and leakage tests for bending cracks and through cracks in the walls of a reinforced concrete water tank were conducted. Material performance tests were also performed. The self-healing performance of bending cracks in a lentic environment and through cracks in a lotic environment were tested, thereby the self-healing width of bending micro-cracks in the lentic environment in the short term were determined. The through cracks had the capacity for self-healing in the lotic environment was found. The leakage characteristics of the bending cracks and through cracks were tested with the actual water head on the crack. The effects on liquid leakage of the width of bending cracks, the depth of the compression zone, and the acting head were determined. The relationships between the leakage rate and time with the height of the water head were analyzed. Based on the tests, the relationships between the crack characteristics and self-healing as well as the leakage were obtained. Thereby the references for water tank structure design and grading earthquake damage were provided.

Shaking table experiment on a steel storage tank with multiple friction pendulum bearings

  • Zhang, Ruifu;Weng, Dagen;Ge, Qingzi
    • Structural Engineering and Mechanics
    • /
    • 제52권5호
    • /
    • pp.875-887
    • /
    • 2014
  • The aim of the shaking table experiment is to verify the isolation effect of a storage liquid tank with multiple friction pendulum bearings. A 1:20 scale model of a real storage liquid tank that is widely used in the petroleum industry was examined by the shaking table test to compare its anchored base and isolated base. The seismic response of the tank was assessed by employing the time history input. The base acceleration, wave height and tank wall stress were used to evaluate the isolation effect. Finally, the influences of the bearing performance that characterizes the isolated tank, such as the friction force and residual displacement, were discussed.

액체수소 충전 비율에 따른 액체수소 연료탱크의 내부 압력 거동 비교 (Comparison of the Internal Pressure Behavior of Liquid Hydrogen Fuel Tanks Depending on the Liquid Hydrogen Filling Ratio)

  • 최동국;이수용
    • 항공우주시스템공학회지
    • /
    • 제18권3호
    • /
    • pp.8-16
    • /
    • 2024
  • 수소는 매우 낮은 밀도를 갖기 때문에 화석연료와 동일한 수준의 에너지량을 저장하기 위해서는 기존과 다른 저장방식이 요구된다. 수소의 밀도를 높이는 방법으로는 수소를 액화하여 저장하는 방법이 있다. 하지만, 수소의 액화온도는 -252 ℃의 극저온이기 때문에 외부 열 유입에 의해 쉽게 기화된다. 액체수소가 기화되면 탱크 내부의 압력이 증가되는 자가증압 현상을 발생하므로, 탱크 설계 시 이 상승하는 압력을 잘 예측해야 한다. 따라서, 본 논문에서는 극저온 액체수소 연료탱크의 액체수소 충전 비율에 따른 내부 압력을 예측하였다. 탱크 내부의 압력 상승을 예측하기 위하여 1차원 열역학적 모델을 적용하였다. 열전달 모델은 열 유입, 액체수소의 기화, 연료 배출에 현상이 고려되었다. 최종적으로 연료탱크 내의 액체수소의 충전 비율에 따라 압력 상승 거동과 최대 상승 압력에 큰 차이가 있음을 확인하였다.

The effect of composite-elastomer isolation system on the seismic response of liquid-storage tanks: Part I

  • Shahrjerdi, A.;Bayat, M.
    • Earthquakes and Structures
    • /
    • 제15권5호
    • /
    • pp.513-528
    • /
    • 2018
  • A typical viable technique to decrease the seismic response of liquid storage tanks is to isolate them at the base. Base-isolation systems are an efficient and feasible solution to reduce the vulnerability of structures in high seismic risk zones. Nevertheless, when liquid storage tanks are under long-period shaking, the base-isolation systems could have different impacts. These kinds of earthquakes can damage the tanks readily. Hence, the seismic behaviour and vibration of cylindrical liquid storage tanks, subjected to earthquakes, is of paramount importance, and it is investigated in this paper. The Finite Element Method is used to evaluate seismic response in addition to the reduction of excessive liquid sloshing in the tank when subjected to the long-period ground motion. The non-linear stress-strain behaviour pertaining to polymers and rubbers is implemented while non-linear contact elements are employed to describe the 3-D surface-to-surface contact. Therefore, Nonlinear Procedures are used to investigate the fluid-structure interactions (FSI) between liquid and the tank wall while there is incompressible liquid. Part I, examines the effect of the flexibility of the isolation system and the tank aspect ratio (height to radius) on the tank wall radial displacements of the tank wall and the liquid sloshing heights. Maximum stress and base shear force for various aspect ratios and different base-isolators, which are subjected to three seismic conditions, will be discussed in Part II. It is shown that the composite-base isolator is much more effective than other isolators due to its high flexibility and strength combined. Moreover, the base isolators may decrease the maximum level pertaining to radial displacement.

액체저장탱크의 지진응답해석 모델 중 빔 모델의 적용성 (Applicability of Beam Model among Earthquake Response Analysis Models of Liquid-Storage Tank)

  • 진병무;전세진;김영진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.696-699
    • /
    • 2004
  • Generally, the time history analysis among seismic response analyses of a structure needs more times than static analysis. Therefore the mechanical model of a structure has been used as a simple lumped parameter model in time history analysis. For the most cases, the simple mechanical model shows the similar results to that of detailed finite element model. so it is reasonable to use the simple mode] in preliminary analysis. In seismic design of liquid storage tank, such as LNG storage tank, the lumped parameter mode] also is being used in preliminary analysis, however sometimes shows the differences to the results of detailed finite element model. Therefore in this study, the dynamic characteristics between lumped parameter model and detailed finite model is compared for the variables such as height/diameter of liquid-storage tank and thickness of wall, then the applicability of beam mode] to the seismic response analysis are evaluated for some liquid storage tanks.

  • PDF

연료탱크내 액체연료와 고체입자의 혼합 수치해석 연구 (A Numerical Study on Mixing of Liquid Fuel and Solid Particles in a Fuel Tank)

  • 김명호;유경원;민성기;황기영
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.745-749
    • /
    • 2011
  • 혼합용 임펠러를 장착한 연료탱크의 액체연료와 미세 고체입자의 부유, 혼합 현상을 분석하고자 2차원 혼합 유동 수치해석을 수행하였다. 다상 유동해석은 Eulerian Grandular Multiphase 기법을 사용하였고, 해석기법을 12vol% 고체 혼합 조건 실험의 축방향 고체 농도 분포와 비교하여 확인하였다. 해석용 연료탱크는 10.5vol% 고체입자를 액체연료와 혼합하는 것으로 회전수 700rpm 조건에서 4가지 경우의 임펠러 위치와 유속 조건으로 해석을 수행하였다. 각 경우에 대한 Quality of Suspension 결과를 비교하여 적합한 임펠러 위치와 속도방향을 확인하였다.

  • PDF

액체 슬로싱 제어를 위한 입력성형 (Input Shaping for Control of Liquid Sloshing)

  • 김동주;홍성욱;김경진
    • 한국정밀공학회지
    • /
    • 제28권9호
    • /
    • pp.1018-1024
    • /
    • 2011
  • Liquid sloshing occurs when a partially filled liquid tank is subjected to undesirable external forces or acceleration/deceleration for positioning control. Installation of baffles is still the most popular way to suppress the sloshing, but recent successes of input shaping in reducing structural vibrations may give a possible alternative. We aim at investigating the applicability of input shaping to sloshing suppression by numerically solving fluid motions in a rectangular tank. The tank is partially filled with water and it is suddenly put into a sequence of horizontal motions of acceleration and constant speed. The flow is assumed to be two-dimensional, incompressible, and in viscid, and a VOF two-phase model is used to capture the free surface. Results show that the sloshing can be successfully suppressed by shaping the input, i.e., the velocity or acceleration profile of tank. Three different input shapers (ZII, ZVD, and two-mode convolved ZV shapers) are tested and compared in this study Among them, the convolved ZV shaper shows a best performance to eliminate the sloshing almost completely.

방향전환 기동 시 액체연료가 위성체의 관성모멘트 및 자세운동에 미치는 영향 분석 (Effects of Liquid Fuel on Spacecraft's Moment of Inertia and Motion during Reorientation)

  • 강자영;이상철
    • 한국항공운항학회지
    • /
    • 제17권1호
    • /
    • pp.1-8
    • /
    • 2009
  • In this paper, reorientation based on angular momentum exchange is applied for a bias momentum stabilized satellite, which is equipped with a spherical fuel tank, and the effect of liquid slosh on the attitude properties such as inertia tensor and angular rate is investigated. In order to represent the slosh motion of liquid an equivalent mechanical model is adopted and full nonlinear equations of motion for three-body system are derived. Computer simulations are performed for several cases, which use the viscosity of liquid and the center location of the tank as input parameters, mainly in order to observe how the viscosity of liquid and the center location of the tank influence the spacecraft’s attitude. The investigation includes observing time-variations of the inertia tensor, especially presence of components of product of inertia during the maneuver.

  • PDF

In-situ measurement of railway-traffic induced vibrations nearby the liquid-storage tank

  • Goktepe, Fatih;Kuyuk, Huseyin S.;Celebi, Erkan
    • Earthquakes and Structures
    • /
    • 제12권5호
    • /
    • pp.583-589
    • /
    • 2017
  • In this study, result of a field investigation of railway traffic-induced vibrations is provided to examine acceptability levels of ground vibration and to evaluate the serviceability of a liquid-storage tank. Free field attenuation of the amplitudes as a function of distance is derived by six accelerometers and compared with a well-known half-space Bornitz's analytical solution which considers the loss of the amplitude of waves due to geometrical damping and material damping of Rayleigh. Bornitz's solution tends to overlap vertical free field vibration compared with in-situ measured records. The vibrations of the liquid-storage tank were compared with the USA, Federal Transportation Railroad Administration (FTA) criteria for acceptable ground-borne vibrations and with the criteria in DIN 4150-3 German standard. Comparing the thresholds stated in DIN 4150-3, absolute peak particle velocities are within the safe limits, however according to FTA velocity level at the top of the water tank exceeds the allowable limits. Furthermore, it is intended to indicate experimentally the effect of the kinematic interaction caused by the foundation of the structure on the free-field vibrations.

초음파와 전기전도 센서를 이용한 우레아 탱크 수위, 농도 및 온도의 동시 측정 방안 (Simultaneous Measurement of Liquid-level, Concentration and Temperature of a Urea Tank using Ultrasonic and Electrical Conductivity Sensors)

  • 최병철;김태욱
    • 동력기계공학회지
    • /
    • 제21권5호
    • /
    • pp.71-78
    • /
    • 2017
  • The purpose of this study is to propose the basic data for the development of a sensor capable of simultaneously measuring the liquid-level, concentration and temperature of a urea tank using ultrasonic and electrical conductivity sensors for diesel vehicles with a urea-SCR system. It was found that the liquid-level of the urea tank using the ultrasonic sensor showed a good linearity with the actual liquid-level, and the urea concentration maintained good linearity in the range of 32.5 wt% to 10 wt%. It was an effective measurement of urea concentration to use the electrical conductivity sensor in the temperature range of $-10{\sim}22^{\circ}C$ and to use the ultrasonic sensor at $22^{\circ}C$ or more. Simultaneous measurement of concentration, liquid-level and temperature of the urea tank will be possible by attaching the electrical conductivity sensor and the ultrasonic sensor (split-type) to one sensor together.