• 제목/요약/키워드: Liquid chemical tank

검색결과 40건 처리시간 0.025초

A Simple Method to Make the Quadruple Tank System Near Linear

  • Lee, Jietae;Kyoung, Inhyun;Heo, Jea Pil;Park, YoungSu;Lim, Yugyeong;Kim, Dong Hyun;Lee, Yongjeh;Yang, Dae Ryook
    • Korean Chemical Engineering Research
    • /
    • 제55권6호
    • /
    • pp.767-770
    • /
    • 2017
  • Quadruple tank liquid level systems are popular in testing multivariable control systems for multivariable processes with positive or negative zeros. The liquid level system is nonlinear and it will help to illustrate the robustness of control systems. However, due to nonlinearity, it can be cumbersome to obtain process parameters for testing linear control systems. Perturbation sizes are limited for valid linearized process models, requiring level sensors with high precision. A simple method where the outlet orifice is replaced to a long tube is proposed here. The effluent flow rate becomes proportional to the liquid level due to the friction loss of long tube and the liquid level system shows near linear dynamics. It is applied to the quadruple tank system for easier experiments.

화학물질 저장 탱크와 방류벽 사이의 공간 부족 개선을 위한 누출 방지판의 안정성 평가 기준 (Technical Criterion of Safety Evaluation of Leakage Preventing Plates for Alleviating Space Shortage Between Chemical Storage Tank and Dike)

  • 이은별;곽솔림;최영보
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.42-50
    • /
    • 2018
  • The Chemical Controls Act strictly regulates for the chemical companies to establish sufficient space between the liquid chemical tank and dike, but facilities already installed suffer from the space shortage between the tank and dike. Installing leakage preventing plates on the dike is considered as one of the economic solutions that can alleviate the space deficiency. However, there is no technical and reasonable criterion for the safety evaluation of the leakage preventing plate on the dike. In order to address this problem, we provide generalized and verified calculating equations that give maximum height and horizontal distance of leakage trajectories. Through the proposed equations, proper heights of the leakage preventing plates on the dike can be easily determined. In this study, new calculating methods are also developed to determine the impact force of the liquid to the leakage preventing plates. In addition, we performed the reactivity experiments between four corrosive liquid chemicals and two stainless steel materials that are candidate substances for the construction of the leakage preventing plate. The results of this study is expected to be applicable as a guideline in the design of safe dike and its leakage preventing plates.

약품(액상소석회) 저장조 준설 작업자의 유해인자 특성 평가 사례 (Characteristics of Hazardous Factors Regarding Chemical(Liquid Lime) Storage Tank Dredging Workers)

  • 김제훈;김기연
    • 한국산업보건학회지
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2024
  • Objectives: The study was performed to investigate characteristics of hazardous factors regarding chemical(liquid lime) tank dredging workers by case survey. Methods: Field data such as working condition, MSDS and respirators applied to chemical tank dredging work were analyzed and the work environmental factors of noise and indoor air quality were measured to compare existing data with actual work situations. Results: No health hazards to workers due to working conditions were confirmed during dredging work inside the chemical storage tank. All air quality measurement data during dredging work satisfied the management standards, and there were no by-products. During dredging work, there was a significant change in noise depending on the type of work, but considering the noise reduction rate(NRR) of the earplugs worn by workers, there was no actual health hazard due to noise exposure. Conclusions: A fit test for respirator and the expiration date of the safety helmet should be observed to ensure an appropriate level of safety and health for dredging workers in the chemical storage tank.

마이크로 컴퓨터를 이용한 구형 탱크의 액위 제어 (Liquid level control in a spherical tank by microcomputer)

  • 강원영;오민;이태희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1986년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 17-18 Oct. 1986
    • /
    • pp.459-462
    • /
    • 1986
  • The liquid level in a spherical tank was controlled with a micro-computer and the dynamic behavior of this non-linear system due to the variation of set point was studied. The adaptive control theory was used and the real values of controlled variables were compared with the theoretical values from a mathematical model.

  • PDF

시설원예용 파이프 유도식 무인방제기 개발 (I) - 무인 주행시스템 - (Development of a Self-Travelling Sprayer for a Greenhouse (I) - Self-travelling -)

  • 김태한;장익주;강춘태
    • Journal of Biosystems Engineering
    • /
    • 제24권3호
    • /
    • pp.209-216
    • /
    • 1999
  • A self-travelling sprayer was developed to avoid the exposure of an operator to agricultural chemicals and exhaust gas, to improve safety and to increase working efficiency during the application and transport work in the greenhouses. This system consists of self-travelling system and the control system for application and safety device. The auto-spray car is equipped with a liquid chemical tank of 80l capacity. The travelling system adopted mechanical steering system which link mechanism of front wheel is guided by guide rollers. The sprayer travels along the guiding pipe which is set on the furrow in the greenhouses. The sprayer stops automatically applying and traveling when the liquid chemical tank becomes empty or when the sprayer reach the turning point. The spray booms swings in a vertical plane. The control system of safety devices controls the automatic stop of the sprayer when there is an obstacle on the traveling path, or when the battery becomes discharged. The auto-spray car traveled smoothly and steadily along the guide pipe during traveling straightly and turning on the ground.

  • PDF

Decontamination of radioactive wastewater by two-staged chemical precipitation

  • Osmanlioglu, Ahmet E.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.886-889
    • /
    • 2018
  • This article presented two-staged chemical precipitation for radioactive wastewater decontamination by using chemical agents. The total amount of radioactive wastewater was $35m^3$, and main radionuclides were Cs-137, Cs-134, and Co-60. Initial radioactivity concentration of the liquid waste was 2264, 17, and 9 Bq/L for Cs-137, Cs-134 and Co-60, respectively. Potassium ferrocyanide, nickel nitrate, and ferrum nitrate were selected as chemical agents at high pH levels 8-10 according to the laboratory jar tests. After the process, radioactivity was precipitated as sludge at the bottom of the tank and decontaminated clean liquid was evaluated depending on discharge limits. By this precipitation method decontamination factors were determined as 66.5, 8.6, and 9 for Cs-137, Cs-134, and Co-60, respectively. By using the potassium ferrocyanide, about 98% of the Cs-137 was removed at pH 9. At the bottom of the tank, radioactive sludge amount from both stages was totally $0.98m^3$. It was transferred by sludge pumps to cementation unit for solidification. By chemical processing, 97.2% of volume reduction was achieved. The potassium ferrocyanide in two-staged precipitation method could be used successfully in large-scale applications for removal of Cs-137, Cs-134, and Co-60.

CFD를 이용한 가향 탱크 내부 유동에 관한 연구 (A Study on Internal Flow of Mixing Tank by CFD)

  • 정한주;조성일;양진철
    • 한국연초학회지
    • /
    • 제32권2호
    • /
    • pp.63-69
    • /
    • 2010
  • In the chemical, mineral and electronics, mechanically stirred tanks are widely used for complex liquid mixing processes. The paper present results from a computational fluid dynamics (CFD) model for the mixing tank in casing process. We used CFD software, FLUENT(Fluent, Inc, Lebanon, NH, version 6.2). A species transport model was used to model the problem. The flow patterns in a mixing tank, 1.6 m in diameter and 2.0 m in height, were studied using CFD. Numerical analysis results show that improved mixing tank was reduced low speed flow region and turbulent region in internal flow of mixing tank.

Liquid Membrane Permeation of Nitrogen Heterocyclic Compounds Contained in Model Coal Tar Fraction

  • Kim, Su-Jin;Kang, Ho-Cheol;Kim, Yong-Shik;Jeong, Hwa-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1143-1148
    • /
    • 2010
  • We investigated the separation of nitrogen heterocyclic compound (NHC) contained in a model coal tar fraction comprising four kinds of NHC [indole (In), quinoline (Q), iso-quinoline (iQ), quinaldine (Qu)], three kinds of bicyclic aromatic compound (BAC) [1-methylnaphthalene (1MN), 2-methylnaphthalene (2MN), dimethylnaphthalene (DMN) mixture with ten structural isomers (DMNs; regarded as one component)], biphenyl (Bp) and phenyl ether (Pe) by liquid membrane permeation (LMP). A batch-stirred tank was used as the permeation unit. An aqueous solution of saponin and n-hexane were used as the liquid membrane and the outer oil phase, respectively. Yield and selectivity of individual NHC was much larger than that of BAC, Bp and Pe. Increasing the initial mass fraction of the saponin to the membrane solution ($C_{sap,0}$) and the initial volume fraction of O/W emulsion to total liquid in a stirred tank (${\phi}_{OW,0}$) resulted in deteriorating the yield of individual NHC, but increasing the stirring speed (N) resulted in improving the yield of each NHC. With increasing $C_{sap,0}$, the selectivity of each NHC based on DMNs increased. Increasing ${\phi}_{OW,0}$ and N resulted in decreasing the selectivity of individual NHC based on DMNs. At an experimental condition fixed, the sequence of the yield and selectivity in reference to DMNs for each NHC was Q > Qu = iQ > In. Furthermore, we compared LPM method with methanol extraction method in view of the separation efficiency (yield, selectivity) of NHC.

가압 염소포화액체 저장탱크의 2상 흐름 누출에 대한 유해위험거리의 예측을 위한 결과영향 모델링 방법론 (Consequence Modeling Methodology for Prediction of Hazard Distance for Two-phase Flow Release from the Pressurized Chlorine Saturated Liquid Storage Tank)

  • 송덕만;박영석;박종규
    • 한국가스학회지
    • /
    • 제2권4호
    • /
    • pp.7-17
    • /
    • 1998
  • 본 연구는 화학장치설비중 가압 염소포화액체 저장탱크의 2상흐름 연속누출에 대한 유해위험거리(또는 독성완충거리)를 정량적으로 예측하기 위한 결과영향 모델링 방법론을 개발하기 위한 것이다. 누출원 모델링은 미환경청의 가이드라인에 근거한 정교한 해석방법과 SuperChems 모델의 자체계산에 의하여 각각 수행되었다. 유해위험성 평가에서 법적 독성규제농도로서 사용되는 STEL, IDLH 및 ERPGs (ERPG-2와 ERPG-3) 농도들에 대하여 유해위험거리를 예측하였다. 비상대응계획 수립시 유해위험성 평가의 가이드라인으로 활용하기 위하여 특히 ERPG-2 농도에 대하여 누출원특성 및 기상변화들의 유해위험거리에 미치는 영향을 고찰하였다.

  • PDF