• 제목/요약/키워드: Liquid breakdown

검색결과 175건 처리시간 0.024초

Development of Liquid Stub and Phase Shifter

  • Wang, Son-Jong;Yoon, Jae-Sung;Hong, Bong-Guen
    • Nuclear Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.201-208
    • /
    • 2001
  • The high power RF transmission line components are required for transmitting MW level RF power continuously in RF heating and current drive system which heat the plasma and produce plasma current in fusion reactor The liquid stub and phase shifter is proposed as the superior to the conventional stub and phase shifter. Experimental results show that they are reliable and easy to operate compared to the conventional stub and phase shifter. There is no distortion of reflected power during the raising of the liquid level. RF breakdown voltage is over 40kV. Temperature increment of the liquid is expected not to be severe. These results verify that the liquid stub and phase shifter can be used reliably in the high power continuous RF facilities.

  • PDF

극저온화에 따른 액화 $SF_6$ 및 액체질소의 방전특성 (Discharge Characteristics of Liquid $SF_6$ & $N_2$ at Very Low Temperature)

  • 최은혁;이현철;윤대희;박광서;김종환;박창기;김기채;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1808-1810
    • /
    • 2004
  • This paper describes the discharge characteristics of liquid $SF_6$ (-41$[^{\circ}]$, 1.7[atm]) and $LN_2$ for plane to plane, needle to plane, plane to needle and sphere to plane electrode with gap variations from 1[mm] to 12[mm]. From this result, the breakdown voltage was increased with increasing gap length. Especially, the formation of bubbles by evaporation was observed in spite of non-applying voltage source. A corona is created of the applying voltage from the bubbles on the electrodes applied voltage. We consider it equal mechanism of corona as void exists in solid insulator. The results of liquid $SF_6$ and $LN_2$ discharge characteristics were caused by bubble formed evaporation and applied electric field voltage. Corona was happened to weak bubble and was proceed to new bubble breakdown.

  • PDF

Double Pancake Coil형 고온초전도 변압기의 전기적 절연 특성 (Dielectric Insulation Properties of Double Pancake Coil Type HTS Transformer)

  • 백승명;정종만;이현수;한철수;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권2호
    • /
    • pp.151-156
    • /
    • 2003
  • High temperature superconductor can only be applied against an engineering specofication that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. However, in order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. Therefore, the composite insulation of double pancake coil type transformer are described and AC breakdown voltage characteristics of liquid nitrogen(LN$_2$) under HTS pancake coil electrode made by Bi-2223/Ag are studied. The Breakdown of LN$_2$ is dominated electrode shape and distance. The influence of pressure on breakdown voltage is discussed with th different electrode. For the electrical insulation design of turn-to-turn insulation for the HTS transformer, we tested breakdown strength of insulation sheet under varying pressure. And we investigated surface flashover properties of LN$_2$ and complex conition of cryogenic gaseous nitrogen(CGN$_2$) obove a LN$_2$ surface. The surface voltage of GFRP was measured as a function of thickness and electrode distance in LN$_2$ and complex condition of CGN$_2$ above a LN$_2$ surface. this research presented information of electrical insulation design for double pancake coil(DPC) type HTS transformer.

Double Pancake Coil형 고온초전도 변압기의 전기적 절연 설계를 위한 절연파괴 특성 (Breakdown Properties for Electrical Insulation Design of Double Pancake Coil Type HTS Transformer)

  • 백승명;정종만;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.52-57
    • /
    • 2002
  • High temperature superconductors can only be applied against an engineering specification that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. However, in order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. Therefore, the composite insulation of double pancake coil type transformer are described and ac breakdown voltage characteristics of liquid nitrogen($LN_{2}$) under HITS pancake coil electrode made by Bi-2223/Ag are studied. Breakdown in $LN_{2}$ is dominated electrode shape and distance. And we investigated AC breakdown properties of $LN_{2}$ and complex conition of cryogenic gaseous nitrogen($CGN_{2}$) obove a $LN_{2}$ surface. Also, the surface voltage of GFRP was measured as a function of thickness and electrode distance in $LN_{2}$ and complex condition of $CGN_{2}$ above a $LN_{2}$ surface. This research presented information of electrical insulation design for double pancake coil type HTS transformer.

  • PDF

초전도 한류기의 턴간 절연특성 (Dielectric Characteristics of Turn-ro-Turn Insulation for SFCL)

  • 백승명;정종만;이창화;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 초전도 자성체 연구회
    • /
    • pp.65-68
    • /
    • 2003
  • Interconnected power system operation has given rise to the problem of increased fault levels and leads to over stressing of all the components. Use have been made of recently developed high Tc superconductor in devising a superconducting fault current limiter (SFCL) that promises optimum performance in terms of capital cost, size, auto sensing, operational losses, response time and reliability. Recently, research about the application of the SFCL is actively progressing in Korea. To be applied for SFCL practically, the electrical insulation design of SFCL must be developed. Therefore, this paper presents the result of an investigation of the dielectric characteristics of turn-to-turn insulation for SFCL in liquid nitrogen. The dielectric characteristics of turn-to-turn insulation models of SFCL were investigated. We obtained following results. The breakdown voltages increased as the spacer thickness and length increased. And the breakdown voltages of turn-to-turn model without spacer were higher than the breakdown voltages of turn-to-turn model with spacer under impulse as well as AC voltages. The information gathered in this test series should be helpful in the design of liquid nitrogen filled SFCL.

  • PDF

Breakdown Properties in Physiological Saline by High Voltage Pulse Generator

  • Byeon, Yong-Seong;Song, Ki-Baek;Uhm, Han-Sup;Shin, Hee-M.;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.333-333
    • /
    • 2011
  • We have investigated the breakdown properties in liquids by high voltage pulse system. High voltage pulse power system is consisted of the Marx-generator with two capacitors (0.5 ${\mu}F$, withstanding voltage is 40 kV), to which the charging voltage can be applied to maximum 30 kV DC, spark gap switch and charging resistor of 20 $M{\Omega}$. We have made use of tungsten pin electrodes of anode-cathode (A-K), which are immersed into the liquids. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current monitor (IPC CM-1.S). Especially the high speed breakdown or plasma propagation characteristics in the pulsed A-K gap have been investigated by using the high speed ICCD camera. We have measured the electron temperature through the Boltzmann plot method from the breakdown spectrums. Here the A-K gap has been changed by 1 mm, 2 mm, and 3 mm. The used liquids are distilled water and solution of salt (0.9 %). The output voltage and current signals at breakdown in distilled water are shown to be bigger than those in saline solution. The breakdown voltage and current characteristics in liquids will be discussed in accordance with A-K gap distances. It is also found that the electron temperatures and plasma densities in liquids are decreased in conformity with A-K gap.

  • PDF

초전도 케이블용 절연재료의 절연파괴 특성과 기구에 관한 연구 (Study on the Breakdown Characteristics and Mechanisms of Insulating Material for Superconducting Cable)

  • 김현희;권영환;마대영;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 춘계학술대회 논문집
    • /
    • pp.44-48
    • /
    • 1993
  • Recently, superconducting cable has attracted a great deal of interest from the viewpoint of energy saving, one of the most important and difficult problems to be solved to assure the high reliability, safety and economy of cable is breakdown is cryogenic temperature. In this paper, we will report on the characteristics and mechanisms of the breakdown and creeping discharge in cryogenic liquids, dual role of those as the cooling and insulating material, and composited system of cryogenic liquid - gas taking into consideration for application.

  • PDF

건조공기/에폭시 복합절연물의 AC 파괴전압 분석 (Analysis of AC Breakdown Voltage of Composite Insulation for Dry-Air/Epoxy)

  • 허준;이승수;임기조;정해은;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.289-290
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

저밀도 폴리에틸렌 필림의 결정화도 및 전기적 특성 (The crystallinity and electrical characteristics of low density polyetylene thin film)

  • 윤중락;권정열;이헌용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.164-168
    • /
    • 1996
  • The relation between crystallinity and thermal history in low density polyethylene thin films and their effect on electric conduction phenomena and dielectric breakdown was studied. The low density polythylene thin films obtained by the solution growth method heat-treated at 140[$^{\circ}C$] for 2 h and subsequently cooling to various ways. The degree of crystallinity was estimated by the X-ray diffraction measurement for the specimen of slowly cooling, ICE quenching and liquid nitrogen quenching. The result shows that the crystallinity decreases become faster as the cooling speed increased, and that conduction phenomenon is governed by the space charge limited current in high field. It was found that the dielectric breakdown field increases with an increase in cooling speed and test number in self-healing breakdown method.

  • PDF

평등전계시 $SF_6$의 상변화에 따른 절연파괴특성 (Breakdown Characteristics about $SF_6$ in Different Slate under Uniform Fields)

  • 최은혁;박혜리;우성훈;장승호;김이국;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.261-264
    • /
    • 2008
  • In this paper the experiments of breakdown characteristics $SF_6$ liquid ($LSF_6$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, The ability of $LSF_6$ insulation is higher than high-pressurized $SF_6$ gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery which will be studied and developed in the future.

  • PDF