• 제목/요약/키워드: Liquid Time-constant

검색결과 151건 처리시간 0.02초

Comparison of Potential and Viscous Codes for Water Entry Problem

  • Kwon, Sun-Hong;Park, Chang-Woo;Shin, Jae-Young
    • International Journal of Ocean System Engineering
    • /
    • 제2권1호
    • /
    • pp.32-36
    • /
    • 2012
  • This paper presents a comparison of potential and viscous computational codes for the water entry problem. A po-tential code was developed which adopted the boundary element method to solve the problem. A nonlinear free surface boundary condition was integrated to find new locations of free surface. The dynamic boundary condition was simplified by taking constant potential values for every time steps. The simplified dynamic boundary condition was applied in the new position of the free surface not at the mean level, which is the usual practice for linearized theory. The commercial code FLUENT was used to solve the water entry problem from the viscosity point of view. The movement of the air-liquid interface is traced by distribution of the volume fraction of water in a computational cell. The pressure coefficients were compared with each other, while experimental results published by other researchers were also examined. The characteristics of each method were discussed to clarify merits and limitations when they were applied to the water entry problems.

"Leak Current" correction for critical current measurement of no-insulation HTS coil

  • Song, Jung-Bin;Hahn, Seungyong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.48-52
    • /
    • 2017
  • Discrepancy between a power supply current and an actual "spiral" coil current makes the conventional 4-probe measurement of a critical current ($I_c$) of a no-insulation (NI) high temperature superconductor (HTS) coil inaccurate and time-consuming. This paper presents a fast and accurate approach for $I_c$ measurement of NI HTS coils. With an NI HTS coil energized at a constant ramping rate, a complete analytic expression for the spiral coil current was obtained from a first-order partial differential equation that derived from an equivalent circuit model of the NI coil. From the analytic solution, both spiral coil current and radial leak current can be obtained simultaneously, which enables fast and accurate measurement of the NI coil $I_c$. To verify the proposed approach, an NI double-pancake (DP) coil, wound with GdBCO tapes of $6mm{\times}0.1mm$, was constructed and its $I_c$ was repeatedly measured with various ramping rates in a bath of liquid nitrogen at 77 K. The measured results agreed well with the calculated ones, which validates the proposed approach to measure $I_c$ of an NI HTS coil.

수직환상주형내 Al-Cu합금의 응고과정 및 냉각속도의 조대편석에 대한 영향 (Solidification Process of an Al-Cu Alloy in a Vertical Annular Mold and Effects of Cooling Rate on Macrosegregation)

  • 유호선
    • 대한기계학회논문집
    • /
    • 제18권7호
    • /
    • pp.1818-1832
    • /
    • 1994
  • Transport process during solidification of an AI-CU alloy in a vertical annular mold of which inner wall is cooled is numerically simulated. A model which can take account of local density dependence on the solute concentration is established and incorperated in the analysis. Results show that thermally and solutally induced convections are developed in sequence, so that there is little interaction between them. Thermal convection effectively removes the initial superheat from the melt and vanishes as solidification proceeds from the cooling wall. On the other hand, solutal convection which is developed later over the meshy and the pure liquid regions leads to large-scale redistribution of the consituents. The degree of the initial superheating hardly affects overall solidification behavior except the early stage of the process, when the cooling rate is kept constant. Macrosegregation is reduced remarkably with increasing cooling rate, because not only the liquidus interface advances so quickly that time available for the solute transport is not enough, but also the interdendritic flow is strongly damped by rapid crystal growth within the mushy region.

이단중유연소 버너의 수치해석적 연구 (Flame simulation on the two stage heavy oil combustion)

  • 이승수;김혁주;박병식;김종진;최규성
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.209-214
    • /
    • 2002
  • Computations were performed to investigate the flow, temperature and pollutants in two stage heavy-oil combustion burner. The burner geometry and flow conditions were provided by a burner company. The goal of the study is to understand combustion phenomena according to each air inlet's velocity, excessive air ratio and air temperature through CFD. Air flow rates at two inlets are adjusted by a damper inside a burner. Here, injection conditions of liquid fuel are kept constant throughout all simulations. This assumption is made in order to limit the complexity of oil combustion though it may cause some disagreement. The final goal of this research is to design a Low-NOx heavy oil combustion burner through comparison between computational study and experimental ones. Besides experiments, simulation works can give us insights into heavy oil combustion and help us design a Low NOx burner while saving time and cost. The computational study is based on k-e model, P-1 radiation model(WSGGM) and PDF, and is implemented on a commercial code, FLUENT.

  • PDF

Pharmacokinetics of Diltiazem and its Major Metabolite, Deacetyldiltiazem after Oral Administration of Diltiazem in Mild and Medium Folate-Induced Renal Failure Rabbits

  • Choi, Jun-Shik;Lee, Jin-Hwan;Burm, Jin-Pil
    • Archives of Pharmacal Research
    • /
    • 제24권4호
    • /
    • pp.333-337
    • /
    • 2001
  • The pharmacokinetic changes of diltiazem (DTZ) and its main metabolite, deacetyldiltiazem (DAD) were studied after oral administration of DTZ to normal rabbits and mild and medium folate-induced renal failure rabbits. DTZ 10 mg/kg was given to the rabbits either orally (n=6). Plasma concentrations of DTZ and DAD were determined by a high performance liquid chromatography assay. The area under the plasma concentration-time curves (AUC) and maximum plasma concentration ($C_{max}$) of DTZ were significantly increased in mild and medium folate-induced renal failure rabbits. The metabolite ratio of the DTZ to DAD were significantly decreased in mild and medium folate-induced renal failure rabbits. The volume of distribution ($V_{d}$) and total body clearance ($CL_{t}$) of DTZ were significantly decreased in mild and medium folate-induced renal failure rabbits. The elimination rate constant ($\beta$) of DTZ was significantly decreased in folate-induced renal failure rabbits, but that of DAD was significantly increased. These findings suggest that the hepatic metabolism of DTZ was inhibited and the $V_{d}$, $CL_{t}$ and $\beta$ of DTZ were significantly decreased in mild and medium folate-induced renal failure rabbits.

  • PDF

Chemical coagulation and sonolysis for total aromatic amines removal from anaerobically pre-treated textile wastewater: A comparative study

  • Verma, Akshaya K.;Bhunia, Puspendu;Dash, Rajesh R.
    • Advances in environmental research
    • /
    • 제3권4호
    • /
    • pp.293-306
    • /
    • 2014
  • The present study primarily focuses on the evaluation of the comparative effect of chemical coagulation and ultrasonication for elimination of aromatic amines (AAs) present in anaerobically pretreated textile wastewater containing different types of dyes including azo dyes. Color and COD reduction was also monitored at the optimized conditions. The production of AAs was measured spectrophotometrically in the form of total aromatic amines (TAAs) and also verified with high performance liquid chromatography (HPLC) selectively. A composite coagulant, magnesium chloride (MC) aided with aluminium chlorohydrate (ACH) in an equal ratio (MC + ACH) was utilized during the coagulation process, which yielded 31% of TAAs removal along with 85% of color and 52% of COD reduction. At optimized power (200 W) and sonication time (5 h), an appreciable TAAs degradation efficiency (85%) was observed along with 51% color reduction and 62% COD removal using ultrasonication. The chromatographic data indicate that sulphanilic acid and benzidine types of aromatic amines were produced after the reductive cleavage of utilized textile dyes, which were effectively mineralized after ultrasonication. The degradation followed the first order kinetics with a correlation coefficient ($R^2$) of 0.89 and a first-order kinetic constant (k) of $0.0073min^{-1}$.

Acid green-25 removal from wastewater by anion exchange membrane: Adsorption kinetic and thermodynamic studies

  • Khan, Muhammad Imran;Ansari, Tariq Mahmood;Zafar, Shagufta;Buzdar, Abdul Rehman;Khan, Muhammad Ali;Mumtaz, Fatima;Prapamonthon, Prasert;Akhtar, Mehwish
    • Membrane and Water Treatment
    • /
    • 제9권2호
    • /
    • pp.79-85
    • /
    • 2018
  • In this work, batch adsorption of anionic dye acid green-25 (AG-25) from aqueous solution has been carried out at room temperature using anion exchange membrane (DF-120B) as a noval adsorbent. The effect of various experimental parameters such as contact time, membrane dosage, ionic strength and temperature on the adsorption of dye were investigated. Kinetic models namely pseudo-first-order, pseudo-second-order, Elovich, liquid film diffusion, Bangham and modified freundlich models were employed to evaluate the experimental data. Parameters like adsorption capacities, rate constant and related correlation coefficients for every model are calculated and discussed. It showed that adsorption of AG-25 onto DF-120B followed pseudo-first-order rate expression. Thermodynamic study indicates that adsorption of AG-25 onto DF-120B is an exothermic and spontaneous process.

하이브리드 자동차용 엔진 내부의 전자식 수온조절기의 감온성 및 유량제어 정확도 향상을 위한 수치 및 실험적 연구 (Numerical and Experimental Study to Improve Thermal Sensitivity and Flow Control Accuracy of Electronic Thermostat in the Engine for Hybrid Vehicle)

  • 정수진;정진우;하승찬
    • 한국분무공학회지
    • /
    • 제26권3호
    • /
    • pp.135-141
    • /
    • 2021
  • High-efficient HEV Engine cooling systems reflects variable coolant temperature because it can decrease the hydrodynamic frictional losses of lubricated engine parts in light duty conditions. In order to safely raise the operating temperature of passenger cars to a constant higher level, and thus optimize combustion and all accompanying factors, a new thermostat technology was developed : the electronically map-controlled thermostat. In this work, various crystalline plastics such as polyphthalamide (PPA) and polyphenylenesulfide (PPS) mixed with various glass fiber amounts were introduced into plastic fittings of automotive electronic controlled thermostat for the purpose of suppressing influx of coolant into the element and undesirable opening during hot soaking. Skirt was installed around element frame of automotive electronic controlled thermostat for improving thermal sensitivity in terms of response time, hysteresis and melting temperature. To validate the effectiveness and optimum shape of skirt, thermal sensitivity test and three-dimensional CFD simulation have been performed. As a consequence, important improvement in thermal sensitivity with less than 3℃ of maximum coolant temperature between opening and engine inlet was obtained.

인젝터 구동 전류 패턴 변화가 솔레노이드 타입 커먼레일 인젝터 분사율 특성에 미치는 영향에 대한 컴퓨터시뮬레이션 (A Computer Simulation of Injection Rate Characteristics of Solenoid Type Common Rail Injector According to Injector Driving Current Patterns)

  • 이충훈
    • 한국분무공학회지
    • /
    • 제24권3호
    • /
    • pp.114-121
    • /
    • 2019
  • The effect of injector driving current pattern on fuel injection rate of solenoid diesel common rail injector was studied by computer simulation. The time resolved fuel injection rate and injected quantity per stroke of a common rail injector driven with the five current patterns were computer simulated. The fuel injection rate and injected quantity per stroke according to the rail pressure and fuel injection period were also computer simulated. When the common rail injector was driven with the five driving current patterns of peak & hold, there was no difference in the fuel injection rate in the peak section regardless of all the current patterns of the five cases. On the other hand, the magnitude of the hold current value influenced the injection rate and injected quantity per stroke. That is, in the current pattern of three cases where the hold current value is equal to or more than a constant value of the peak current value, the fuel injection rates for the given common rail rail pressure and injection period are same one another. On the other hand, the current pattern of the two cases, in which the hold current value is smaller than a certain value, there is a large fluctuation in the fuel injection rate.

간접냉각시스템을 이용한 인코넬 718소재의 가공성 평가 (Machinability Evaluation of Inconel 718 Material Using Indirect Cooling System)

  • 김진형;이여울;박성환;이동진;강명창
    • 한국기계가공학회지
    • /
    • 제18권2호
    • /
    • pp.96-101
    • /
    • 2019
  • This paper presents a machinability evaluation of Inconel 718 material when using a new uniform-temperature indirect cooling method that incorporates constant-pressure liquid nitrogen (LN2). The flank wear of a TiAlN coated tool used with this indirect cooling system was much lower than that of the tool used with dry machining under all machining conditions. Also, the surface roughness resulting from machining with this indirect method was far less than that of a dry machined surface after the same cutting time. Reduced heat generation and uniform temperature in turning operations play important roles in tool life and surface quality.