Development and Performance Evaluation of a Liquid Particle Generator (액적 발생 장치 개발 및 성능 평가)

  • Heo, Jung-Hyuk;Kim, Dae-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4334-4340
    • /
    • 2012
  • In this work, we developed and evaluated the Liquid Particle Generator for generating fine particles in the air. The Liquid Particle Generator, which was based on the spray-evaporation method, had two kinds of orifices: 0.3 mm and 0.5 mm. The Liquid Particle Generator was operated at different pressure between 1 bar and 4 bars to find relationship between input pressure and droplet output rate. In addition, the size distribution of the droplets generated by the Liquid Particle Generator with different orifices was measured by the SMPS system and the optical particle counter. As a result, it was shown that the Liquid Particle Generator with 0.3 mm orifice generated droplets of around 0.3 ${\mu}m$ and atomized particles very stably. The Liquid Particle Generator having 0.5 mm orifice generated bigger droplets, compared with the Liquid Particle Generator with 0.3 mm orifice. Additionally, in these Liquid Particle Generators (0.3 mm and 0.5 mm orifice), little coagulation of particles did occur because of fine droplets atomized by the jet. Therefore, the Liquid Particle Generator could be used as an aerosol generator for atomizing fine particles.

Measurement of Liquid-Metal Flow with a Dynamic Neutron Radiography (중성자 래디오그래피를 이용한 액체금속 유동장 측정)

  • Cha, Jae-Eun;Saito, Yasushi
    • Journal of the Korean Society of Visualization
    • /
    • v.9 no.4
    • /
    • pp.63-68
    • /
    • 2011
  • The flow-field of a liquid-metal system is very important for the safety analysis and the design of the steam generator of liquid-metal fast breeder reactor. Dynamic neutron radiography (DNR) is suitable for a visualization and measurement of a liquid metal flow and a two-phase flow in a metallic duct. However, the three dimensional DNR techniques is not enough to obtain the velocity information in the wide channel up to now. In this research, a high speed DNR technique was applied to visualize the heavy liquid-metal flow field in the narrow channel with the HANARO-beam facility. The images were taken with a high frame-rate neutron radiography at 250 fps and analyzed with a Particle Image Velocimetry(PIV) method. The images were compared with the results of the commercial CFX code to study the feasibility of DNR technique for the measuring the heavy liquid-metal flow field. The PIV images could discern the turbulent vortex flow in the two-dimensional narrow channel.

Breakdown Properties in Physiological Saline by High Voltage Pulse Generator

  • Byeon, Yong-Seong;Song, Ki-Baek;Uhm, Han-Sup;Shin, Hee-M.;Choi, Eun-Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.333-333
    • /
    • 2011
  • We have investigated the breakdown properties in liquids by high voltage pulse system. High voltage pulse power system is consisted of the Marx-generator with two capacitors (0.5 ${\mu}F$, withstanding voltage is 40 kV), to which the charging voltage can be applied to maximum 30 kV DC, spark gap switch and charging resistor of 20 $M{\Omega}$. We have made use of tungsten pin electrodes of anode-cathode (A-K), which are immersed into the liquids. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current monitor (IPC CM-1.S). Especially the high speed breakdown or plasma propagation characteristics in the pulsed A-K gap have been investigated by using the high speed ICCD camera. We have measured the electron temperature through the Boltzmann plot method from the breakdown spectrums. Here the A-K gap has been changed by 1 mm, 2 mm, and 3 mm. The used liquids are distilled water and solution of salt (0.9 %). The output voltage and current signals at breakdown in distilled water are shown to be bigger than those in saline solution. The breakdown voltage and current characteristics in liquids will be discussed in accordance with A-K gap distances. It is also found that the electron temperatures and plasma densities in liquids are decreased in conformity with A-K gap.

  • PDF

Collection Characteristics of a MOUDI Cascade Impactor for Coarse Particles (다단 임팩터(MOUDI)의 조대 입자 채취 특성)

  • 배귀남;지준호;문길주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.6
    • /
    • pp.799-804
    • /
    • 1999
  • Particle collection characteristics of the MOUDI cascade impactor has been studied for coarse particles in the range of 2 to 20$mu extrm{m}$ in aerodynamic diameter. A vibrating orifice aerosol generator was empolyed to generate monodisperse test aerosols. The oleic acid and sodium chloride(NaCl) particles were used as test aerosols. Aluminum foil and Teflon filter were selected as impaction media. The sampling flow rate was changed from 25 to 35L/min. Particle collection efficiency for single stage was examined for liquid particles. The stage response was obtained experimentally for the cascade impactor composed of three stages and a backup filter. The results showed that most of particle collection efficiencies measured in this work are similar to the efficiency curves obtained by Marple et al.(1991). For particles less than cut-off size of the stage, the collection efficiencies of solid particles are similar to those of loquid particles. However, the collection efficiency of solid particles decreases with mereasing particle diameter for the particles greater than the actual cut-off size of the impactor. The particle collection efficiency increases with increasing sampling flow rate at the same particel size. However, the collection efficiency curves seem not to be greatly shifted with the flow rate. The stage responses obtained by direct measurements in this work are in good agreement with those derived from the collection efficiency curves for single stage.

  • PDF

An Experimental Study on Swirling Flow in a Sudden Expansion Tube using 3D PIV Technique (3D PIV 기법을 이용한 선회유동의 급팽창에 관한 실험적 연구)

  • Chang, Tae-Hyun;Kil, Sang-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.272-281
    • /
    • 2009
  • The effect of swirl on the flow characteristics in a sudden expansion tube was examined experimentally by using 3D PIV(particle image velocimetry) to capture the velocity profiles. The swirling flow of water through a sudden 1:2 axisymmetric expansion has previously been studied experimentally within a horizontal round tube. A kind of tangential slot is used as a swirl generator for swirling flow and a honey comb is used for without swirl flow. The work with the swirl and without swirl results are compared to each other at the same Reynolds number. Liquid crystal was employed to measure temperature profiles and heating coil used for heat transfer with and without swirl flow. And then the Nusselt number ratoes(Nu/Nudb) are calculated along the test section.

An experimental study on the impingement spray of a common-rail diesel injector (2) -atomization characteristics- (커먼레일식 디젤 인젝터의 충돌 분무에 대한 실험적 연구(2) -미립화 특성-)

  • Lee, C.S.;Park, S.W.;Seo, S.H.
    • Journal of ILASS-Korea
    • /
    • v.8 no.3
    • /
    • pp.19-26
    • /
    • 2003
  • In this study, experimental study on atomization characteristics of the fuel spray impinging on the wall was at different wall distances and angles of wall inclination. The fuel injection system was composed based on the common rail system. and the injection signal was synchronized by the delay generator. The atomization characteristics of the injected spray were analyzed in terms of the SMD and velocities which were measured by using the phase Doppler particle analyzer system. It is revealed that the free spray is atomized actively above 50mm form the injector tip. In the cases of the impinged spray, the 5MD and velocity of the impinged spray are smaller than those of the free spray. The impinged spray has the maximum near the 35mm of the radial distance from the injector axis, and the atomization performance is enhanced with the decrease of the wall distance.

  • PDF

The Fundamental Study on th e Soil Remediation for Copper Contaminated Soil using Nanobubble Water (나노버블수에 의한 구리 오염 토양의 정화에 관한 기초 연구)

  • Jeong, So-Hee;Kim, Dong-Chan;Han, Jung-Geun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.1
    • /
    • pp.31-39
    • /
    • 2017
  • The fundamental study for an application of nanobubble as a soil remediation enhancer on heavy metal contaminated soil was carried out. The existence and long-term stability of hydrogen nanobubbles were investigated by particle analysis and zeta-potential analysis. And the removal efficiency of copper using nanobubble water(NBW) and distilled water(DW) were compared and analyzed through a batch desorption test. As a result, it is confirmed that nanobubble which was fabricated by compression-dissolution type generator can exist for more than 14 days. The results of batch test show that copper removal of NBW was higher than that of DW irrespectively to soil type and increased as solid-liquid ratio and contact time increased, respectively. According to the pH change, the removal of copper on sand was higher on the acid side but the removal difference was slightly lower on the clay. It is considered that a high efficiency of NBW in copper removal is due to the large surface area and high zeta-potential of nanobubbles. Therefore, the nanobubble can be applied to soil remediation for heavy-metal contaminated soil as an eco-friendly enhancer.