• 제목/요약/키워드: Liquid Nitrogen

검색결과 1,389건 처리시간 0.03초

Simple and Flexible Temperature Control System for Space Environment Test

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won;Choi, Seok-Weon
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.29.1-29.1
    • /
    • 2008
  • The temperature control system which is using liquid and gaseous nitrogen has been known as the most economical system to simulate space temperature condition due to relatively not expansive price of the liquid nitrogen (less than 0.2 USD per liter). And, among these systems, the closed loop system which circulates compressed nitrogen gas come from sprayed liquid nitrogen by blower and makes a target temperature with heat from an electrical heater and flow rate of liquid nitrogen is prevail all over the world. But, this complete closed loop system requires expansive equipments such as blower, heater, and liquid nitrogen injector, and special maintenance on the system. Therefore, KARI is developing efficient and simple open loop system which utilizes liquid and gaseous nitrogen with eliminating a special blower and other expansive units. In this study, this open loop system with more efficiency and flexibility will be designed and introduced.

  • PDF

Lubrication Effect of Liquid Nitrogen in Cryogenic Machining Friction on the Tool-chip Interface

  • Jun Seong-Chan
    • Journal of Mechanical Science and Technology
    • /
    • 제19권4호
    • /
    • pp.936-946
    • /
    • 2005
  • The liquid nitrogen as an environmentally safe coolant has been widely recognized in cryo­genic machining, its function as a lubricant is plausible due to its chemical inertness, physical volatility and low viscosity. Since a reduced friction is a direct witness of the lubrication effect from a tribological viewpoint, this paper presents an evaluation of the apparent friction coefficient on the tool-chip interface in cryogenic cutting operations to prove and characterize the lubricity of LN2 in cryogenic machining. The cryogenic cutting technology used in this study is based on a cooling approach and liquid nitrogen delivery system which are intended to apply liquid nitrogen in well-controlled fine jets to selectively localized cutting zones and to penetrate liquid nitrogen to the tool-chip interface. It has been found that the apparent friction coefficient can be significantly reduced in cryogenic machining, depending on the approach of liquid nitrogen delivery.

액체질소를 이용한 액체 로켓 엔진 연소 가스 냉각 특성 연구 (A Study on Cooling Characteristics of Combustion Gas by Liquid Nitrogen in a Liquid Rocket Engine)

  • 전준수;이양석;송재강;김유;고영성
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.147-150
    • /
    • 2007
  • 본 연구에서는 액체로켓엔진의 연소 가스에 액체 질소를 혼합하여 연소 가스의 냉각 특성을 알아보고자 하였다. 이를 위해 기존에 사용되던 액체로켓 연소실 후단에 액체 질소 분사용 분사기를 설계/제작하여 장착하였으며, 두 가스의 혼합 가스의 안정화를 위한 연소실과 노즐을 질소 분사링 뒤에 장착하였다. 액체질소 분사에 의한 상류 점화/연소 상태의 영향을 살펴보기 위한 시험이 먼저 수행되었으며, 이후 10초 연소 실험을 성공적으로 수행하였다. 따라서 기존의 액체로켓엔진에 액체질소를 분사함으로써, 연소 가스의 온도를 저하시킬 수 있음을 확인하였다.

  • PDF

액화질소에 의한 간흡충 피낭유충의 살충에 대한 연구 (Larvicidal Action of Liquid Nitrogen against. Metacercariae of Clonorchis sinensis)

  • 송수복
    • Parasites, Hosts and Diseases
    • /
    • 제25권2호
    • /
    • pp.123-128
    • /
    • 1987
  • The author investigated the larvicidal action of liquid nitrogen against the metacercariae of Clonorchis sinensis, with an observation on the freshness and change of taste in the flesh of fishes. The results obtained were as follows: 1. The metacercariae in the mesh of Pseudorasbora parve, which were treated with liquid nitrogen ($-192^{\circ}C$), were not killed within 10 seconds, but completely killed over 30 seconds. In comparison, the metacercariae in the flesh of p. parka kept in a refrigerator ($-12^{\circ}C$) were killed only in 84% in 10-hour exposure group. 2. The freezing speed of fishes by liquid nitrogen was 4 min.(') and 15 seconds(") for Cyprinus carpio, 1'22" for Carassius carassius and only $30^{\circ}C$ for Pseudorasbora larva. 3. As for the freshness and taste of raw fresh water fishes, they were not deteriorated after the treatment with liquid nitrogen. 4. In animal infection experiment of C. sinensis metacercariae after freezing, they were found not infective after they were treated with liquid nitrogen. From the results, it is inferred that the treatment of fresh water fishes for longer than 30 seconds with liquid nitrogen is helpful to reduce the possibility of C, sinensis infection without alteration of the freshness and taste of fishes.

  • PDF

연속적으로 누출되는 액체질소 풀의 확산에 관한 실험적 연구 (Experimental Study of Liquid Nitrogen Pool Spreading with Continuous Spill)

  • 최재환;김명배;최병일;김태훈
    • 에너지공학
    • /
    • 제23권3호
    • /
    • pp.174-180
    • /
    • 2014
  • 연속적으로 누출되는 극저온 액체의 풀 확산을 액체질소를 사용하여 실험적으로 연구하였다. 본 실험을 위해 Cement mortar 재질의 Plate 위에 액체질소를 연속적으로 누출시켜 Plate 표면에서 풀 확산이 일어나도록 하였다. 전자저울을 이용하여 Plate 위에서 증발되는 액체질소의 단위면적당증발률을 측정했고, 시간에 따라 반경 방향으로 퍼지는 액체풀의 확산 거리는 열전대의 온도 변화로부터 측정하였다. 실험 결과 액체질소의 단위면적당증발률은 풀 확산이 진행될수록 감소하는 경향을 보였다.

톡소플라즈마원충(原蟲)(RH주(株))의 5년간 동결보존시험 (Preservation of Toxoplasma gondii (RH strain) in liquid nitrogen for 5 years)

  • 전영;장환
    • 대한수의학회지
    • /
    • 제33권2호
    • /
    • pp.285-287
    • /
    • 1993
  • Toxoplasma gondii frozen by the method of very slow cooling ($-30^{\circ}C/3hrs.{\rightarrow}\;-60^{\circ}C/lhr.{\rightarrow}\;-196^{\circ}C$ of liquid nitrogen)were inoculated mice after storage in the liquid nitrogen for 5 years. The results obtained were as follows; 1. Toxoplasma gondii was detected in mice 4~5th day after intraperitoneal inoculation of organisms stored in the liquid nitrogen once a year for 5 years. 2. Toxoplasma gondii could be preserved longer than 5 years in liquid nitorgen being evidenced by the in vivo test.

  • PDF

77K 이하 극저온 상에서의 부분방전 특성 분석 (Analysis of Partial Discharge Characteristics at Cryogenic Temperature below 77K)

  • 이상화;김복렬;신우주;이방욱;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1562-1563
    • /
    • 2011
  • Partial discharge measurement is one of the effective diagnostic techniques to predict abnormal high voltage dielectric insulation conditions of the electric equipments. Recently partial discharge diagnostic techniques were also utilized to evaluate the cryogenic dielectric insulation of high temperature superconducting electric equipment in liquid nitrogen. Generally, liquid nitrogen at 77 K is used used as the cryogenic and dielectric media for many high temperature superconducting high voltage applications. When a quench in the superconductor occurs, bubbles are generated which can affect the dielectric properties of the liquid nitrogen. So in order to reduce the bubble formation, subcooled nitrogen was also employed for this purpose. In this work, investigation of partial discharge characteristics of subcooled liquid nitrogen were conducted in order to clarify the retardation of partial discharge initiation voltage according to the different subcooling temperature of liquid nitrogen. And also the relation of partial discharge phenomena and the activities of bubbles were analyzed. It was observed that PD inception voltages shows rather different characteristics according to the decrease of subcooling temperature and the activities of bubbles were strongly influenced by temperature of the subcooled liquid nitrogen.

  • PDF

액상 황산철(liquid ferrous sulfate)을 육계 깔짚에 처리시 암모니아 발생량, pH및 총 질소 함량 변화 (Changes in Ammonia Fluxes, pH and Total Nitrogen in Liquid Ferrous Sulfate-treated Litter)

  • 정태호
    • 한국환경과학회지
    • /
    • 제28권2호
    • /
    • pp.287-290
    • /
    • 2019
  • This study investigates the changes in ammonia fluxes, pH and total nitrogen of liquid ferrous sulfate-treated litter over 5 weeks. A total of 200 broiler chicks (Arbor Acres, 1 d old) was separated into two treatment groups (0 g and 100 g liquid ferrous sulfate/kg litter) with four replications of 25 birds in each group. Liquid ferrous sulfate was sprayed on the litter by using a small sprayer. There was no difference (p>0.05) in the ammonia fluxes observed between the control and liquid ferrous sulfate treatment groups at 0, 1, and 5 weeks, except for 2, 3 and 4 weeks. At 5 weeks, the litter pH and total nitrogen content did not show any difference (p>0.05) between the control and liquid ferrous sulfate treatment groups. In conclusion, the use of liquid ferrous sulfate is not a suitable for use in poultry litter to reduce ammonia and pH or improve the total nitrogen content.

고압의 가압식 액체질소 공급 설비 구축 (Construction of High-Pressure Pressurized Liquid Nitrogen Supply Facilities)

  • 신민규;오정화;김석원;고영성;정용갑
    • 항공우주시스템공학회지
    • /
    • 제14권5호
    • /
    • pp.26-32
    • /
    • 2020
  • 본 연구에서는 액체로켓 연소기의 연소 불안정 모사를 위해 극저온 유체인 액체질소를 공급하는 설비를 구축하였다. 가압 및 공급 성능을 예측하였으며 실험을 통하여 검증하였다. 액체질소 공급 시스템은 가압식 공급 시스템으로 구성하였으며, 가압제 압력 조정은 돔 레귤레이터를 사용하였다. 액체질소 공급 유량 제어는 캐비테이션 벤추리를 사용하였으며, 액체 질소 공급 조건은 초당 유량 2.55 kg/s, 벤추리 입구 압력은 100 bar 이상이다. 초기 실험 결과 예측된 가압제의 양이 충분히 공급되지 못하여, 탱크압력 강하가 발생해 목표 유량을 공급하지 못하였다. 구축된 설비의 변경 및 보완을 통하여, 최종적으로 목표 유량 공급에 성공하여 극저온 액체질소 공급 설비를 검증하였다.

액체질소 중 열기포 형상 및 절연 특성 (Shape and Dielectric Strength of Thermal Bubbles in Liquid Nitrogen)

  • 백승명;김해종
    • 한국전기전자재료학회논문지
    • /
    • 제28권5호
    • /
    • pp.326-331
    • /
    • 2015
  • In this paper, we study the insulating properties of the liquid nitrogen(LN2) including the thermal bubbles. The shape of the thermal bubbles in accordance with the current change was observed in the 77 K and 65 K LN2. According to the temperature of liquid nitrogen, bubbles were generated differently. The round shape of the bubble is occurred in 77 K LN2. But the layer shape of bubble is occurred in 65 K LN2. When the bubbles present, the dielectric strength of liquid nitrogen is low. However, the breakdown patterns were different according to the electrode arrangement. AC breakdown voltage(BDV) was lower than the DC BDV due to the influence of bubbles. Therefore, the design of a high-voltage superconducting equipments should consider the bubbles.