• Title/Summary/Keyword: Liquefied natural gas (LNG)

Search Result 263, Processing Time 0.023 seconds

Program Development on the Thermofluidodynamic Analysis of LNG Storage Tanks (LNG 저장탱크의 종합 열유동 해석프로그램 개발)

  • Kim Hoyeon;Choi Sunghee;Bak Young;Lee Junghwan;Yoon Ikkeun;Kim Donghyuk;Ha Jongmann;Joo Sangwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.2 s.14
    • /
    • pp.52-61
    • /
    • 2001
  • Cryogenic LNG(Liquefied Natural Gas) which is stored in the cylindrical storage tanks of $100,000m^3$ has very complex flow phenomena and the changes of thermal properties with exterior conditions and operation modes. These complex thermofluid behaviors are affected by the storage, exterior conditions of LNG, design specifications and heat transfer characteristics of tanks. Also, those have influence on the stable storage and supply of LNG in the storage tanks. Thus this study peformed the analysis on the 2-D heat transfer of the tank with exterior conditions, on the Cool Down Process in order to cool down the LNG Storage Tank at the initial normal state, and on the Filling Process considered for incoming and rising of LNG. The analysis on the Mixing LNG Storage was studied too. At last, the visualized program on the complex thermofluidodynamic analysis was developed on the basis of the above analyses. The development of this program becomes to be used to the basic design of the commercial tanks as well as to assure technical skill of the analysis on the thermal stability of the stored LNG in the LNG Storage Tank.

  • PDF

A Study on Development of Mobile LNG Yard Tractor Refueling Standards (이동식 LNG 야드트랙터 충전 기준 개발 연구)

  • Ryou, Young-don;Yu, Chul-hee;Koo, Bon-deuk;Lee, Dong-won
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.59-64
    • /
    • 2018
  • As part of measures to reduce fine dust, the government is promoting a project to convert the fuel of Yard Tractors(YT, tractors operated at ports), from diesel to LNG (Liquefied Natural Gas). While a port having a small number of yard tractors, it is not proper to construct a stationary LNG fueling station and supply LNG to YT due to a problem of BOG (Boil off gas) generation. Therefore, it is necessary to make a regulation and a standard on mobile LNG YT refueling station installation and inspection as an alternative. In this study, we have investigated domestic and foreign mobile LNG refueling cases and refueling standards, including the USA and Europe. In addition, we have suggested the risk reduction method according to the cause after investigation of the cause of LNG accidents. And last, based on the proposed risk reduction measures, we have proposed an amendment to the Regulation of the Urban Gas Business Law in Korea. The proposed mobile LNG YT refueling amendment of the Regulation includes ; maintenance of the safety distance from the protection facility, installation of an interlock device to prevent refueling in places other than the authorized place, installation of the identification system through biometrics, separation of the tank lorry and tow vehicle before refueling, checking the wheel fixed status of tank lorry before refueling, construction of the impounding area, safety measures before, during and after refueling, etc. The safety standards proposed in this study could be used as a reference in establishing standards for mobile LNG vehicle refueling in the near future.

Improvement of Gas Turbine Performance Using LNG Cold Energy (액화천연가스의 냉열을 이용한 가스터빈의 성능향상)

  • Kim, Tong Seop;Ro, Sung Tack;Lee, Woo Il;Choi, Mansoo;Kauh, Sang Ken
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.653-660
    • /
    • 1999
  • This work describes analysis on the effect of inlet air cooling by the cold energy of liquefied natural gas(LNG) on the performance of gas turbines. Gas turbine off-design analysis program to simulate the influence of compressor inlet temperature variation is prepared and an inlet air cooler is modeled. It is shown that the degree of power augmentation is much affected by the humidity of inlet air. If the humidity is low enough, that is the water content of the air does not condense, the temperature drop amounts to $18^{\circ}C$, which corresponds to more than 12% power increase, in case of a $1350^{\circ}C$ class gas turbine with methane as the fuel. Even with 60% humidity, about 8% power increase is possible. It is found that even though the fuel contains as much as 20% ethane in addition to methane, the power improvement does not change considerably. It is observed that if the humidity is not too high, the current system is feasible oven with conceivable air pressure loss at the inlet air cooler.

Study on the Calculation of Towing Force for LNG Bunkering Barge (LNG 벙커링 바지의 예인력 계산에 관한 연구)

  • Oh, Seung-Hoon;Jung, Jae-Hwan;Hwang, Sung-Chul;Jung, Hyun-Woo;Cho, Seok-Kyu;Jung, Dong-Ho
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2018.11a
    • /
    • pp.158-161
    • /
    • 2018
  • In this paper, the towing force is calculated for the LNG bunker barge. LNG bunkering barge is being developed as an infrastructure for the bunkering of LNG(Liquefied Natural Gas), an eco-friendly energy source. In the case of the LNG bunker barge, a self-propulsion is considered through retrofit from an operating point. Therefore, the LNG bunker barge is similar to the shape of the ship as compared to a towed barge, so a rule of the towed barge overestimates the towing force. In order to improve accuracy, the calm water resistance is calculated according to the ITTC 1978 method considering the wave resistance by the Rankine source method. The added resistance in waves is calculated using the modified radiated energy method considering the shortwave correction method of NMRI. The performance of the towing resistances through the calm water resistance and the added resistance in waves was compared with rules of the towed barge.

  • PDF

Study on the Estimation of Towing Force for LNG Bunkering Barge (LNG 벙커링 바지의 예인력 산정에 관한 연구)

  • Oh, Seung-Hoon;Jung, Dong-Ho;Jung, Jae-Hwan;Hwang, Sung-Chul;Cho, Seok-Kyu;Sung, Hong-Gun
    • Journal of Navigation and Port Research
    • /
    • v.42 no.6
    • /
    • pp.378-387
    • /
    • 2018
  • In this paper, the towing force for the LNG bunkering barge was investigated. Currently, LNG bunkering barge is being developed as an infrastructure for the bunkering of LNG (Liquefied Natural Gas), an eco-friendly energy source. In the case of the LNG bunkering barge, self-propulsion is considered through retrofit from an operating point. Therefore, the LNG bunkering barge's shape is similar to that of the ship as compared to a towed barge, so a rule of the towed barge overestimates the towing force. In order to improve accuracy, the calm water resistance was calculated using ITTC 1978 method which considers wave resistance by the Rankine source method. The added resistance in waves was calculated using the modified radiated energy method which considers the shortwave correction method of NMRI. The performance of the towing resistances through the calm water resistance and the added resistance in waves was compared to rules associated with towed barges.

Mechanical Properties Analysis of Epoxy and Polyurethane Adhesive for Accurate Structural Analysis of LNG Cargo Hold (LNG 화물창 정밀 구조해석을 위한 에폭시와 폴리우레탄 접착제 기계적 물성치 분석)

  • Jeong, Yong-Cheol;Jeong, Yeon-Jae;Kim, Jeong-Dae;Park, Seong-Bo;Kim, Yong-Tai;Oh, Hoon-Gyu;Lee, Jae-Myung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.2
    • /
    • pp.66-72
    • /
    • 2021
  • As the demand for natural gas that satisfies environmental regulations increases, the quantities of natural gas cargo that carrier can load is also increasing. Natural gas is transported in a liquefied state at -163 ℃ to increase loading efficiency. Among several LNG CCS types, MARK-III types are generally adopted in terms of loading efficiency. The secondary barrier adhesives of the MARK-III, nevertheless, is subjected to tensile stress due to thermal contraction and tension in the environment. In terms of these reasons, local analysis of the adhesive to evaluate the stress state must be carried out. According to previous studies, local analysis is unavailable since material properties for secondary barrier adhesives have not been reported. Thus, in this study, the cryogenic tensile test and coefficient of thermal expansion of epoxy and polyurethane (PU15, PU45), which are most widely used at cryogenic temperatures, were experimentally analyzed. At cryogenic temperature, the mechanical behavior of the polyurethane adhesive was better than epoxy of the adhesive. the joint of FSB and epoxy adhesive of the secondary barrier has the maximum coefficient of thermal expansion difference at 25 ℃ and minimum at -150 ℃, respectively.

Program Development on the Thermofluidodynamic Analysis of LNG Storage Tanks (LNG 저장탱크 종합 열유동 해석프로그램 개발)

  • Kim, Ho-Yeon;Choi, Sung-Hee;Lee, Jung-Hwan;Bak, Young;Ha, Jong-Mann;Joo, Sang-Woo
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.683-688
    • /
    • 2001
  • Cryogenic LNG(Liquefied Natural Gas) which is stored in the cylindrical storage tanks of $100,000m^{3}$ has very complex flow phenomena and the changes of thermal properties with exterior conditions and operation mdoes. These complex thermofluid behaviors are affected by the storage, exterior conditions of LNG, design specifications and heat transfer characteristics of tanks, Also, those have influence on the stable storage and supply of LNG in the storage tanks. Thus this study performed the analysis on the 2-D heat transfer of the tank with exterior conditions, on the Cool Down Process in order to cool down the LNG Storage Tank at the initial normal state, and on the Filling Process considered for incoming and rising of LNG. The analysis on the Mixing LNG Storage was studied too. At last, the visualized program on the complex thermofluidodynamic analysis was developed on the basis of the above analyses. The development of this program becomes to be used to the basic design of the commercial tanks as well as to assure technical skill of the analysis on the thermal stability of the stored LNG in the LNG Storage Tank.

  • PDF

An Experimental Study on the NOx Formation of LNG Flame in Fuel Staged Combustor (다단 연소기를 이용한 LNG 화염의 NOx 발생에 관한 실험적 연구)

  • Chung, Jin-Do;Han, Ji-Woong;Ahn, Kook-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.4
    • /
    • pp.389-394
    • /
    • 2004
  • An experimental study on the NOx formation of LNG flame in fuel staged combustor has been studied. The design concept of multi fuel/air staged combustor is creation of two separate flame, a primary flame is a act as a pilot flame for the secondary combustion stage combustion zone, where most of fuel bums. Experiments were performed on a semi-industrial scale (thermal input 0.233 MW) in a laboratory furnace and Liquefied Natural Gas(LNG) was used as a primary and secondary fuels. This study included parametric study to identify the optimum operating conditions which are primary/secondary fuel ratio, and primary/secondary air ratio for reducing NOx emission with two types of nozzle. The test demonstrated that NOx emission can be reduced by >70% in accordance with operating conditions.

An Experimental study on the NOx Formation of LNG Flame in Fuel Staged Combustor (다단 연소기를 이용한 LNG 화염의 NOx 발생에 관한 실험적 연구)

  • Han, Ji-Woong;Ahn, Kook-Young;Kim, Han-Seok;Chung, Jin-Do;Park, Kyung-Jin
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.161-166
    • /
    • 2001
  • An Experimental study on the NOx formation of LNG flame in fuel staged combustor has been studied. The design concept of multi fuel/air staged combustor is creation of two separate flame, a primary flame is act as a pilot flame for the secondary combustion stage combustion zone, where most of fuel burns. Experiments were performed on a semi-industrial scale (thermal input 0.233 MW) in a laboratory furnace and Liquefied Natural Gas(LNG) was used as primary and secondary fuels. The study included parametric study to identify the optimum operating conditions which are primary/secondary fuel ratio, and primary/secondary air ratio for reducing NOx emission with two types of nozzle. The test demonstrated that NOx emission can be reduced by >70% in accordance with operating conditions.

  • PDF

Analysis method on Structural Safety Evaluation of Butterfly Valve of Piping for LNG carrier (LNG 선박용 배관에 사용되는 Butterfly Valve의 구조 안정성 평가에 관한 해석 기법)

  • Park, Young-Chul;Park, Han-Seok;Kim, Si-Pom
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.4
    • /
    • pp.76-81
    • /
    • 2008
  • A cryogenic butterfly valve is used to transfer the liquefied natural gas (LNG) which temperature is $-162^{\circ}C$. This valve is core part in the piping system using LNG. This paper performed coupling analysis using FEM to evaluate safety of cryogenic butterfly valve. Flow analysis is calculated numerically the CAE and CFD methods are useful to predict the thermal matter and the inner flow field of the valve. Thermal analysis and structural analysis used ANSYS Workbench.

  • PDF