• Title/Summary/Keyword: Link Quality

Search Result 768, Processing Time 0.024 seconds

Design of DC Battery Size & Controller for Household Single-Phase ESS-PCS Considering Voltage Drop and DC Link Voltage Ripple (주택용 단상 ESS-PCS의 전압손실과 직류링크 맥동을 고려한 직류측 배터리 사이즈 및 제어기 설계)

  • Kim, Yong-Jung;Lee, Jinsung;Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.2
    • /
    • pp.94-100
    • /
    • 2018
  • Generally, in a single-phase energy storage system (ESS) for households, AC ripple component with twice the fundamental frequency exists inevitably in the DC link voltage of single-phase PCS. In the grid-connected mode of a single-phase inverter, the AC ripple component in the DC link voltage causes low-order harmonics on grid-side current that deteriorates power quality on an AC grid. In this work, a control system adopting a feedforward controller is established to eliminate the AC ripple interference on the DC link side. Optimal battery nominal voltage design method is also proposed by considering the voltage loss and AC ripple voltage on DC link side in a single-phase ESS. Finally, the control system and battery nominal voltage design method are verified through simulations and experiments.

Proposal of an Algorithm for an Efficient Forward Link Adaptive Coding and Modulation System for Satellite Communication

  • Ryu, Joon-Gyu;Oh, Deock-Gil;Kim, Hyun-Ho;Hong, Sung-Yong
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.2
    • /
    • pp.80-86
    • /
    • 2016
  • This paper proposes the algorithm for forward link adaptive coding and modulation (ACM) and the detailed design for a satellite communication system to improve network reliability and system throughput. In the ACM scheme, the coding and modulation schemes are changed by as much as the channel can provide depending on the quality of the communication link. To implement the forward link ACM system in the Ka-band, channel prediction and modulation/coding decision methods are proposed and simulated. The parameters of the adaptive filter predictor based on the least mean square are optimized, the minimum mean square error of the channel predictor is 0.0608 when step size and the number of filter tap are 0.0001 and 4, respectively. A test-bed is set up to verify the forward link ACM system, and a test is performed using a Ka-band satellite (i.e., Communication, Ocean, and Meteorological Satellite [COMS]). This test verifies that the ACM scheme can increase the system throughput.

A Technique to Link Bug and Commit Report based on Commit History (커밋 히스토리에 기반한 버그 및 커밋 연결 기법)

  • Chae, Youngjae;Lee, Eunjoo
    • KIISE Transactions on Computing Practices
    • /
    • v.22 no.5
    • /
    • pp.235-239
    • /
    • 2016
  • 'Commit-bug link', the link between commit history and bug reports, is used for software maintenance and defect prediction in bug tracking systems. Previous studies have shown that the links are automatically detected based on text similarity, time interval, and keyword. Existing approaches depend on the quality of commit history and could thus miss several links. In this paper, we proposed a technique to link commit and bug report using not only messages of commit history, but also the similarity of files in the commit history coupled with bug reports. The experimental results demonstrated the applicability of the suggested approach.

DC link Ripple Voltage Compensation of a Single-phase Grid-Connected PV System (단상 계통연계형 태양광 발전 시스템의 직류링크 맥동전압 보상)

  • Lee, Jae-Geun;Choi, Jong-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.377-387
    • /
    • 2012
  • A single-phase grid-connected PV system is known as suitable for housing of less than 3 kW. The DC link voltage in a single-phase PV system has necessarily twice component of fundamental wave. It makes high THD in the grid current. According to the problem, power quality is lower. Many engineers have studied about this problem. The most simple method is to use low pass filter on DC link voltage control. However it is affected by DC link voltage control bandwidth. If cutoff frequency is reduced to increase the performance of low pass filter, it also lowers DC link voltage control bandwidth. Second method is using band stop filter, it works good on steady state but not good on transient state. This paper proposes the new method for removing ripple voltage to get an exact current reference. It improves the responses on steady state and transient state. The performance was verified through computer simulation using MATLAB and actual experiments.

On the Performance of All-optical Amplify-and-forward Relaying with a Backup Radio-frequency Link Over Strong Atmospheric Turbulence and Misalignment Fading

  • Altubaishi, Essam Saleh
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.114-120
    • /
    • 2021
  • Free-space optical (FSO) communication is considered to be a potential solution to congestion in the radio-frequency spectrum and last-mile-access bottleneck issues in future cellular communication networks, such as 5G and beyond. However, FSO link performance may degrade significantly due to irradiance fluctuations and random temporal fluctuations from atmospheric turbulence. Therefore, in this work the main objective is to reduce the effect of the atmospheric turbulence by considering a multihop FSO communication system with amplify-and-forward relaying supported by a radio-frequency (RF) link, which form a hybrid FSO/RF communication system. The FSO link is assumed to follow the gamma-gamma fading model, which represents strong turbulence. Also, the RF link is modeled by a Rayleigh distribution. The performance of the considered system, in terms of the outage probability and average bit-error rate (BER), is investigated and analyzed under various weather conditions and pointing errors. Furthermore, the effect of the number of employed relay nodes on the performance of the system is investigated. The results indicate that the considered system reduces outage probability and average BER significantly, especially for low channel quality. Finally, the closed-form expressions derived in this work are compared to the results of Monte Carlo simulations, for verification.

Studying Route Optimality in Multi-Hop Wireless Mesh Networks (다중 홉 무선 메쉬 네트워크에서 최적 경로에 관한 연구)

  • Kim, Seong-Kwan;Lee, Ok-Hwan;Lee, Sung-Ju;Choi, Sung-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.1B
    • /
    • pp.16-23
    • /
    • 2009
  • This paper investigates how many optimal routes can be established in terms of a given wireless mesh routing metric. Although many of routing metrics have been devised to precisely derive the wireless link quality in mesh, most (if not all) metrics have not been evaluated their optimality along with routing protocols. We consider stateof-the-art routing metrics and a widely accepted routing protocol in order to observe the optimality of established routes varying the number of source nodes. Also, we propose a unidirectional routing to deal with possible link asymmetry feature in wireless links. Through comparative simulation evaluations, we show that the portion of optimally established routes becomes less as the network traffic load increases, regardless of employed metrics, network topologies, and routing protocols.

Design and Simulation of analog controller for 3 Phase PWM Converter Based on Stationary Reference Frame (3상 PWM Converter를 위한 정지 좌표계법 Analog 제어기 설계 및 시뮬레이션)

  • 이영국;노철원;최종률
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.14-20
    • /
    • 1997
  • Due to several advantages of Pulse Width Modulated(PWM) Converter, such as unity power factor with low-harmonics and energy regeneration, PWM converter has been widely used in industrial application. In every application of energy conversion equipment, the design and implementation must be carried out considering performance and cost. High quality with low cost is the best choice for energy conversion equipment. High dc link voltage can reduce inverter and motor side losses and system dimension compare to low dc link voltage. Analog controller can make PWM converter cheaper without considerable degradation of the performance than digital controller. This paper shows the simplified analog controller-for 600V dc link voltage using stationary reference frame control and the simulation results.

  • PDF

An Improvement On-Line Failure Diagnosis of DC Link Capacitor in PWM Power Converters (PWM 전력 컨버터에서 DC 링크 커패시터의 개선된 온라인 고장 진단)

  • Shon, Jin-Geun;Na, Chae-Dong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • DC link electrolytic capacitors are widely used in various PWM power converter system, such as adjustable speed driver(ASD) or DC/DC converter. Electrolytic capacitors, which is the most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. This objective of this paper is to propose a improvement method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC link of PWM power converter. The ESR detection scheme is based on the determination of the electrolytic capacitor AC losses calculated from voltage/current measurement using AC coupling. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity compare with BPF method. Simulation results show the veridity of the proposed on-line ESR estimation method.

Steering Axis Analysis of Multi-link Suspensions with Bushing Compliance (컴플라이언스 특성을 고려한 멀티링크 현가장치의 조향축 해석)

  • Kim, Sang Sup;Kim, Seong Hun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.194-202
    • /
    • 2014
  • Steering axis of suspensions is an important factor that affects ride and handling quality in the vehicle chassis development. Macpherson strut and double wishbone's steering axis are defined geometrically, but multi-link suspensions can not be geometrically analyzed. In this case instant axis theory is commonly used to find a steering axis. Since the steering axis is moving with varying caster and kingpin inclination angle, this method approximately corresponds with exact solution. In this paper, we propose a velocity analysis method to find a pure rotational axis of the wheel relative to suspension arms, that is exact solution of the steering axis. This paper extends the method to analyze the steering axis of multi-link suspensions with bushing compliance. The analysis results applied to double wishbone and multi-link suspensions demonstrate validity and accuracy of the proposed method.

Finite Element Analysis on Welded Part of control Link for Automobile (자동차용 컨트롤 링크 업셋 용접부의 용접성 및 피로강도 향상에 관한 유한요소 해석)

  • 조해용;권혁홍;이봉규
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.6
    • /
    • pp.63-70
    • /
    • 2001
  • This study is concerned with Finite Element Analysis on welded part of control link fur automobile. For analysis, control link was modeled into two parts, ring and rod. Heating condition, temperature distributions and fatigue fracture strength were analyzed using "HEAT III" and "NDURE" module of NISA II. Metal flow in the process of welding was simulat- ed by $DEFORM^{TM}2D$.The analyzed results were compared with experimental inspection. Quality of welded part was able to be improved by controlling metal flow in the process of welding by increase the friction constant of ring part. Heat transfer analysis and flow simulations were in good agreement wish welding experiments.

  • PDF