• Title/Summary/Keyword: Lingual bracket

Search Result 32, Processing Time 0.021 seconds

THE DENTAL ARCH FORM IN NORMAL OCCLUSION (정상교합자의 치열궁 형태)

  • Kwon, Yong-Chul;Sung, Jung-Ok;Kwon, Oh-Won;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.19 no.1 s.27
    • /
    • pp.95-106
    • /
    • 1989
  • This study was designed to investigate dental arch shapes buccally and lingually at Bracket Level of Koreans. This involved studying 63 inviduals (37 males, 26 females) with normal occlusion ranging in age from 17 to 24 years old. The landmarks were digitized and measurements and statistical analysis were performed by NEC 9801 V-M computer. The Results were as Follows: Bicanine width, Bipremolar width and Bimolar width were larger in males than in females. Buccal and lingual arch form and coordination form were obtained by NEC 9801 V-M computer. The parabolic equations which represents buccal and lingual arch form were obtained.

  • PDF

THE POSITIONING ERRORS IN BONDING LINGUAL BRACKETS (설측브라켓 부착시 위치오차에 관한 연구)

  • Choi, Joon-Kyu;Hwang, Hyeon-Shik;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.99-111
    • /
    • 1998
  • The purpose of this study was to evaluate the positioning errors according to the method of bonding lingual brackets. Dental models of twenty orthodontic patients with malocclusion were selected for this study. The positioning errors were measured on each model that brackets were bonded to. Three different bonding methods were used. For the first method the bracket was bonded intimately to the lingual surface of the model. For the second method, the bracket was bonded intimately to the lingual surface after setting up using articulator. The passive bracketing, bonding the bracket ligated first to ideal archwire, was used after setting up as the last method. The results were as follows: 1. The brackets bonded without setting up showed greater angulation errors in the upper 1st premolar and the lower canine than those in other bonding methods. The brackets bonded without passive bracketing showed greater positioning errors in upper central incisor, lower 1st and End premolars. 2. The brackets bonded without setting up showed greater torque error in lower 2nd premolar than those in other bonding methods. The brackets bonded without passive bracketing showed greater torque errors in all upper teeth, lower 1st and 2nd premolars. 3. The brackets bonded without passive bracketing showed greater rotation errors between upper central incisors, lower central incisors, lower lateral and central incisor, lower canine and lateral incisor. 4. The brackets bonded without setting up showed greater in-out errors between upper canine and lateral incisor than those in other bonding methods. The brackets bonded without passive bracketing showed greater in-out errors between upper central incisors, upper central and lateral incisors, upper 1st and 2nd premolars, lower lateral and central incisors, lower canine and lateral incisor. These results suggest that there is a large amount of positioning error in lingual brackets even by an indirect bonding technique, and it may be reduced by passive bracketing.

  • PDF

Incisor inclination indicator for anterior torque control during retraction in lingual orthodontic treatment (설측교정치료에 있어서 전치부 후방 견인시 토오크 조절을 위한 incisor inclination indicator)

  • Hong, Ryoon-Ki;Kim, Tae-Gun;Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.34 no.6 s.107
    • /
    • pp.544-554
    • /
    • 2004
  • A device called incisor inclination indicator to control the axial inclinations of the incisors in the diagnostic setup is introduced. It is used to control the retraction of the maxillary and mandibular incisors. In this article, we describe the use of the incisor inclination indicator to prescribe adequate torque into the anterior lingual brackets and evaluate the results of treatment in a bimaxillary dentoalveolar protrusion case that underwent orthodontic treatment with the pretorqued anterior lingual brackets. Retraction of the maxillary and mandibular incisors was achieved with careful control of the axial inclination. It is indicated that the use of the incisor inclination indicator is an effective adjunctive laboratory procedure for anterior torque control during retraction in lingual orthodontic treatment.

Fracture resistance of ceramic brackets to arch wire torsional force (토오크 양에 따른 세라믹 브라켓의 파절 저항성)

  • Han, Jung-Heum;Chang, Minn-Hii;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.37 no.4
    • /
    • pp.293-304
    • /
    • 2007
  • The purpose of this study was to estimate the fracture resistance of commercially available ceramic brackets to torsional force exerted from arch wires and to evaluate the characteristics of bracket fracture. Methods: Lingual root torque was applied to maxillary central incisor brackets with 0.022-inch slots by means of a $022\;{\times}\;028-inch$ stainless steel arch wire. A custom designed apparatus that attached to an Instron was used to test seven types of ceramic brackets (n = 15). The torque value and torque angle at fracture were measured. In order to evaluate the characteristics of failure, fracture sites and the failure patterns of brackets were examined with a Scanning Electron Microscope. Results: Crystal structure and manufacturing process of ceramic brackets had a significant effect on fracture resistance. Monocrystalline alumina (Inspire) brackets showed significantly greater resistance to torsional force than polycrystalline alumina brackets except InVu. There was no significant difference in fracture resistance during arch wire torsional force between ceramic brackets with metal slots and those without metal slots (p > 0.05). All Clarity brackets partially fractured only at the incisal slot base and the others broke at various locations. Conclusion: The fracture resistance of all the ceramic brackets during arch wire torsion appears to be adequate for clinical use.

Digital Orthodontics using Customized Appliance System (개인 맞춤형 장치를 이용한 디지털 교정치료)

  • Kim, Yoon-Ji R.;Ha, Hye-Jung;Lee, Sung-Jong;Lee, Eon-Hwa;Ryu, Jae-Jun
    • The Journal of the Korean dental association
    • /
    • v.54 no.2
    • /
    • pp.134-141
    • /
    • 2016
  • Use of ready-made orthodontic appliance can lead to inefficiencies in the final stages of the orthodontic treatment. Because patients' teeth have anatomic variations, brackets that have been designed to fit on average tooth surface may result in positional discrepancies when leveling and alignment is completed. As a result, additional steps such as rebonding, wire bending and use of auxiliaries may be needed. Even in patients who have normal tooth anatomy and proper tooth size relationships, precise bracket placement is crucial in order to efficiently control the tooth positions. Digital models can provide advantages in clinical orthodontics as virtual tooth setup could be performed, and clinicians can easily visualize the predicted final occlusion. Through this setup model, customized brackets with individualized prescription and archwires that optimally fit with the patients' dental arches can be produced using CAD/CAM technology. Also, the brackets can be accurately placed with an aid of 3D-printed jigs. The purpose of this article is to introduce the commonly used labial and lingual customized orthodontic appliance systems using digital technology.

  • PDF

Clinical limitations and its solutions of the clear overlay appliance treatment (투명교정장치의 임상적 한계와 그 해결)

  • Bae, Gi-Sun
    • The Journal of the Korean dental association
    • /
    • v.54 no.7
    • /
    • pp.563-574
    • /
    • 2016
  • A clear overlay appliance is a type of a removable appliance made from transparent thermoplastic plastic film that covers the entire dentition to move the teeth. It is one of the most favored orthodontic methods opted for by adult patients; this treatment is esthetic, does not cause discomfort and allows oral hygiene to be easily managed when compared to other conventional fixed treatment methods. However, the use of clear overlay appliances, such as invisalign or clear aligner, is associated with various clinical challenges. In particular, the appliances require longer treatment periods compared to fixed treatment, and due to the structural characteristics of the appliances, it is difficult to make proper posterior occlusion and certain type of tooth movement, including extrusion, rotation and tip. Thus, the clear overlay appliances are regarded as supplementary appliances by most orthodontists and have been used for simple orthodontic treatments, such as partial anterior alignments or orthodontic relapse cases. Owing to the remarkable advancement in the field of 3D digital technology over a period of 15 years, the accuracy and convenience of modern clear overlay appliances have continuously improved. Moreover, orthodontic outcomes have also been greatly improved by the introduction of new materials and successful application of various biomechanical methods from conventional orthodontic treatments in the design of clear overlay appliances. This study investigates the clinical limitations that should be considered during the application of clear overlay appliances and also examines the efforts and methods used to overcome these challenges.

  • PDF

Three-dimensional finite element analysis of initial tooth displacement according to force application point during maxillary six anterior teeth retraction using skeletal anchorage (골격성 고정원을 이용한 상악 6전치 후방 견인시 힘의 적용점 변화에 따른 치아 이동 양상에 관한 유한 요소법적 분석)

  • Kim, Chan-Nyeon;Sung, Jae-Hyun;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.33 no.5 s.100
    • /
    • pp.339-350
    • /
    • 2003
  • The purpose of this study was to investigate the micro-implant height and anterior hook height to prevent maxillary six anterior teeth from lingual tipping and extruding during space closure. We manufactured maxillary dental arch form, bracket and wire, using the computer aided three-dimensional finite element method. Bracket was $.022'{\times}.028'$ slot size and attached to tooth surface. Wire was $.019'{\times}.025'$ stainless steel and $.032'{\times}.032'$ stainless steel hook was attached to wire between lateral incisor and canine. Length of hook was 8mm and force application points were marked at intervals of In. Four micro-implants were implanted on alveolar bone between second premolar and first molar. The heights of them were 4, 6, 8, 10mm starting from wire. We analyzed initial displacement of teeth by various force application point applying force of 150gm to each micro-implant and anterior hook. The conclusions of 4his study are as the following : 1. When the micro-implant height was 4m and the anterior hook height was 5mm and below, anterior teeth were tipped lingually. When the anterior hook height was 6mm and above, anterior teeth were tipped labially. 2. When the micro-implant height was 6mm and the anterior hook height was 6mm and below, the anterior teeth were tipped lingually. When the anterior hook height was 6m and above, the anterior teeth were tipped labially. But lingual tipping of anterior teeth decreased and labial tipping Increased when the micro-implant height was 6mm, compared with 4mm micro-implant height. 3. When the micro-implant height was 8mm and the anterior hook height was 2mm, the anterior teeth were tipped lingually. When the anterior hook height was 3mm and above, labial tipping movement of the anterior teeth increased proportionally. 4. When the micro-implant height was 10mm and the anterior hook height was 2mm and above, labial tipping of the anterior teeth increased proportionally. 5. As the anterior hook height increased, aterior teeth were tipped more labially. But extrusion occurred on canine and premolar area because of the increase of wire distortion. 6. Movement of the posterior teeth was tipped distally during maxillary six anterior teeth retraction using micro-im plant because of the friction between bracket and were Based on the results of this study, we could predict the pattern of the tooth movement according to position of micro-implant and height of anterior hook. It seems that we can find the force application point for proper tooth movement in consideration of inclination of anterior anterior teeth, periodontal condition, overjet and overbite

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE PHENOMENON PRODUCED DURING RETRACTION OF FOUR MAXILLARY INCISORS (상악 4절치의 후방견인시 나타나는 현상에 관한 유한요소법적 분석)

  • Cheon, Ok-Jin;Kim, Tae-Woo;Suhr, Cheong-Hoon
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.525-541
    • /
    • 1995
  • This study was designed to investigate force systems and tooth movements produced by retraction archwire during retraction of four maxillary incisors after the maxillary canine retraction into the maxillary first premolar extraction space using the computer-aided three-dimensional finite element method. A three-dimensional finite element model, consisting of 2248 elements and 3194 nodes, was constructed. The model consisted of maxillary teeth and surrounding periodontal membranes, .022'$\times$.028'-slot brackets, and 5 types of retraction archwires(.019'$\times$.025' stainless steel archwire) modeled using the beam elements. The contact between the wire and the bracket slot was modeled using the gap elements because of the non-linear elastic behaviors of the contact between them. The forces and moments, End displacements produced by retraction archwire were measured at various conditions to investigate the difference according to types of loops, magnitudes of activation force, gable angle, and anterior lingual root torque. The results were expressed quantitative and visual ways in the three-dimensional method. The following conclusions can be drawn from this study.1. When the tear-drop loop archwire was activated, the mesio-distal and lingual translational movements of the teeth helped to close the extraction space, but unwanted movements of the teeth including intrusions and extrusions, and rotational movements in each direction occurred. 2. Activation of T-loop archwire compared with those of other types of retraction archwires produced the least translational movements of the teeth helped to space closure and also the least unwanted movements of the teeth. 3. Increasing amount of activation in the tear-drop archwire led not only to increase of translational movements of the teeth helped to space closure, but also to increase of unwanted movements of the teeth. 4. Addition of gable bend in the tear-drop archwire helped anterior teeth to translational movements in the mesio-distal direction, but increased unwanted movements of the teeth 5. Addition of anterior lingual root torque in the tear-drop archwire helped central and lateral incisor to improve their facio-lingual inclination, but increased unwanted movements of the teeth.

  • PDF

Arch Forms & Dimensions after Orthodontic Treatment by Premolar Extraction (소구치 발치에 의한 교정치료후의 치열궁 형태 및 크기에 관한 연구)

  • Lee, Seung-Mi;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.717-729
    • /
    • 1998
  • This study was done to estimate arch forms and dimensions at the bracket level where archwire was placed in Angle's Class I first premolars extraction cases. 60 post-treatment dental casts which had attained good orthodontic treatment results were used in this study Many landmarks and linear measurement items to describe arch forms and dimensions were determined and measured. With a computer system and digitizer, arch forms were described and linear measurement items were statistically analysed. The following results were obtained. 1. The average labial and lingual arch forms at the bracket level were obtained. 2. Arch forms were expressed by parabolic equations and coefficients of determination. 3. Arch widths were larger in male than in female. 4. There were statistical significances in upper intercanine width, upper interfirst molar width, upper intersecond molar height, lower intercanine width and lower interfirst molar width between both sexes (p<0.05, p<0.01). 5. Interfirst molar width differences between maxilla and mandible were 6.43mm in male and 6.05mm in female.

  • PDF

An Analytical Study on Strain Distribution Using Strain Gauge Attached On Root Surface (치근 부착 스트레인 게이지를 이용한 응력 분포 분석)

  • Kim, Sang-Cheol;Park, Kyu-Chan
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.325-333
    • /
    • 2001
  • Optimal orthodontic treatment could be possible when a orthodontist can predict and control tooth movement by applying a planned force system to the dentition. The moment to force(M/F) ratio at the bracket, has been shown to be a primary determinate of the pattern of tooth movement. As various n/F ratios are applied to the bracket on the tooth crown, strain distribution in periodontium can be changed, and the center of rotation in tooth movement can be determined. It is, therefore, so important in clinicalorthodontics to know the strain distribution in a force system of a M/F ratio. The purpose of this study was to analyze the strain distribution in orthodontic force system by strain gauge attached to tooth root, and to evaluate the usage of the method. For this study, an experimental upper anterior arch model was constructed, where upper central incisors, on the root surface of which, 8 strain gauges were attached, were implanted In the photoelastic resin, as in the case of 4mm midline diastema. Three types of closing of upper midline diastema closure were compared : 1. with elastomeric chain(100g force) in no arch wire, 2. elastomeric chain in .016“ round steel wire, 3. elastomeric chain in .016”x.022“ rectangular steel wire. The results were as follows. 1. Strain distributions on labial, lingual, mesial and distal root surface of tooth were able to be evaluated with the strain gauge method, and the patterns of tooth rotation were understood by presuming the location of moment arm. 2. Extrusion and tipping movement of tooth was seen in closing in no arch wire, and intrusion and bodily movement was seen with steel arch wire inserted.

  • PDF