• 제목/요약/키워드: Linearization Calibration

검색결과 16건 처리시간 0.037초

A New Calibration Method Based on the Recursive Linear Regression with Variables Selection

  • Park, Kwang-Su;Jun, Chi-Hyuck
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1241-1241
    • /
    • 2001
  • We propose a new calibration method, which uses the linearization method for spectral responses and the repetitive adoptions of the linearization weight matrices to construct a frature. Weight matrices are estimated through multiple linear regression (or principal component regression or partial least squares) with forward variable selection. The proposed method is applied to three data sets. The first is FTIR spectral data set for FeO content from sinter process and the second is NIR spectra from trans-alkylation process having two constituent variables. The third is NIR spectra of crude oil with three physical property variables. To see the calibration performance, we compare the new method with the PLS. It is found that the new method gives a little better performance than the PLS and the calibration result is stable in spite of the collinearity among each selected spectral responses. Furthermore, doing the repetitive adoptions of linearization matrices in the proposed methods, uninformative variables are disregarded. That is, the new methods include the effect of variables subset selection, simultaneously.

  • PDF

THE VARIANCE ESTIMATORS FOR CALIBRATION ESTIMATOR IN UNIT NONRESPONSE

  • Son, Chang-Kyoon;Jung, Hun-Jo
    • Journal of applied mathematics & informatics
    • /
    • 제9권2호
    • /
    • pp.869-877
    • /
    • 2002
  • In the presence of unit nonresponse we perform the calibration estimation procedure for the population total corresponding to the levels of auxiliary information and derive the Taylor and the Jackknife variance estimators of it. We study the nonresponse bias reduction and the variance stabilization, and then show the efficiency of the Taylor and the Jackknife variance estimators by simulation study.

Simple Spectral Calibration Method and Its Application Using an Index Array for Swept Source Optical Coherence Tomography

  • Jung, Un-Sang;Cho, Nam-Hyun;Kim, Su-Hwan;Jeong, Hyo-Sang;Kim, Jee-Hyun;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • 제15권4호
    • /
    • pp.386-393
    • /
    • 2011
  • In this study, we report an effective k-domain linearization method with a pre-calibrated indexed look-up table. The method minimizes k-domain nonlinear characteristics of a swept source optical coherence tomography (SS-OCT) system by using two arrays, a sample position shift index and an intensity compensation array. Two arrays are generated from an interference pattern acquired by connecting a Fabry-Perot interferometer (FPI) and an optical spectrum analyzer (OSA) to the system. At real time imaging, the sample position is modified by location movement and intensity compensation with two arrays for linearity of wavenumber. As a result of evaluating point spread functions (PSFs), the signal to noise ratio (SNR) is increased by 9.7 dB. When applied to infrared (IR) sensing card imaging, the SNR is increased by 1.29 dB and the contrast noise ratio (CNR) value is increased by 1.44. The time required for the linearization and intensity compensation is 30 ms for a multi thread method using a central processing unit (CPU) compared to 0.8 ms for compute unified device architecture (CUDA) processing using a graphics processing unit (GPU). We verified that our linearization method is appropriate for applying real time imaging of SS-OCT.

GC에서 검출한계 결정을 위한 새로운 접근 방법에 대한 연구 (Study on the new approaching method to determine limit of detection by gas chromatography)

  • 오도석;신경애;이지아;임종호;신미선
    • 한국산업보건학회지
    • /
    • 제20권4호
    • /
    • pp.217-224
    • /
    • 2010
  • The purity methods to determine LOD/LOQ using standard deviation of the residual, intercept and blank by IUPAC and ACS describe many of the pitfalls and pose significant challenges to analytical chemists. Therefore, the aim of this study is the development of the simple, easy, convenient and statistically significant method to determine LOD in quantitative analysis of organic solvents by GC. The new approaching method by linearization in the given concentration range used coefficient of variation ; ${\sigma}_{n-1}$/S(standard deviation, ${\sigma}_{n-1}$ and average, S) of sensitivity(Response/concentration). The comparison of results among the purity methods(IUPAC and ACS) and the linearization have been fulfilled the F-test for standard deviations and t-test for LOD range values. The results of F-test and t-test are satisfied within 95 % confidence level, respectably. The LOD values determined by the new procedure are n-Hexane 0.0116 mg/$m^3$, Toluene 0.0807 mg/$m^3$, and o-Xylene 0.0494 mg/$m^3$. Because the standard deviation of the residual, intercept and blank and the slope of calibration curve are not calculated and the new approaching method use the coefficient of variation of sensitivity by linearization, this new method is simple, easy, convenient and statistically significant. In future, many chemical analysts will expect to applicate and routinely use this method in the all quantitative analysis.

개구관에서의 정체압을 이용한 차동 압력 방식의 휴대형 호흡측정 시스템 개발 (A Development Of The Portable Spirometry System Of Pressure Method Using Static Pressure In Pitot Tube)

  • 이종수;신창민;김영길
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권6호
    • /
    • pp.479-486
    • /
    • 2001
  • 호흡 측정기는 기도를 통해 환자의 폐에 드나드는 기체의 양을 측정하여 호흡에 관련된 기능을 판단하는 의료기기이다. 수술실에서 전신 마취시 사용하는 마취기용 인공호흡기는 미미한 양의 마취제 과용으로도 환자의 생명을 앗아갈 수 있으므로 정확한 호흡량 측정이 특히 중요하다. 본 연구에서는 호흡량 측정에 영향을 주는 요인들로부터 정확한 유량을 산출해내는 방법에 대해 고찰하고. 마취용 인공호흡기에 적용하여 수술환자의 호흡특성을 알아내는 호홉측정기를 구현하였다. 인공호흡기에 많이 사용되고 있는 차동압력형 유량센서를 이용하여 압력, 온도, 가스구성의 상관관계에 따라 유랑을 계측하였으며 유량-타동압력의 비선형적 관계를 선형화하였다. 또한, 휴대형 기기에 적합하도록 전력 효율을 최대화 할 수 있게 시스템을 설계하였다

  • PDF

초정밀 직선 이송계용 능동 자기예압 공기베어링에 관한 연구 (Study on the Air Bearings with Actively Controllable Magnetic Preloads for an Ultra-precision Linear Stage)

  • 노승국;김수현;곽윤근;박천홍
    • 한국정밀공학회지
    • /
    • 제25권6호
    • /
    • pp.134-142
    • /
    • 2008
  • In this paper, we propose a precise linear motion stage supported by magnetically preloaded air bearings. The eight aerostatic bearings with rectangular carbon porous pads were located only one side of vertical direction under the platen where four bearings are in both sides of horizontal direction as wrap-around-design, and this gives simpler configuration than which constrained by air bearings for all direction. Each of the magnetic actuators has a permanent magnet generating static magnetic flux far required preload and a coil to perturb the magnetic farce resulting adjustment of air- bearing clearance. The characteristics of porous aerostatic bearing are analyzed by numerical analysis, and analytic magnetic circuit model is driven for magnetic actuator to calculate preload and variation of force due to current. A 1-axis linear stage motorized with a coreless linear motor and a linear encoder was designed and built to verify this design concept. The load capacity, stiffness and preload force were examined and compared with analysis. With the active magnetic preloading actuators controlled with DSP board and PWM power amplifiers, the active on-line adjusting tests about the vertical, pitching and rolling motion were performed. It was shown that motion control far three DOF motions were linear and independent after calibration of the control gains.

옥내외 광고용 디지털 인쇄의 색 관리 방안에 관한 연구 (A Study on the Color Management Plan of Digital Printing for Indoor and Outdoor Advertisement)

  • 김주정;오성상;조가람;이재수
    • 한국인쇄학회지
    • /
    • 제31권1호
    • /
    • pp.15-37
    • /
    • 2013
  • Split digital printing into interior and outdoors on present advertisement. When is printing machine for interior mainly, use ink of water-based type. Equipment of this type embodies high resolution, but ink special quality light stability is weak. Also, when is printing machine for outdoors, printing machines of solvent or UV type are used because of water resistance and light stability. This printing machines hard to embody ink special quality high resolution mainly. And because outside is far visibility range, is uncommon in case high resolution requires embodiment. Therefore, high resolution of inside is water-based type considering this item and outside printing machine of low resolution solvent type mainly announce. Also, divide into eco-friendly latex ink type that is announced to water-based, solvent, UV according to ink type and the latest market using in occasion of digital printing machine used as advertisement industry. Color management that is been consistent of original image has a lot of difficulties by using substrate that is also various to digital printing machine for such various advertisement. But, consumers is rising realization about color or desire about quality improvement of color gradually in interior outside advertisement market. So, require solution method. Therefore, in this paper, eco-friendly ink use applied device calibration through linearization in done latex digital printing machine to basis. And studied right color management plan of digital printing for interior outside advertisement through three steps such as G7 calibration application and ICC profile application.

Network-RTK측량에서 심플렉스해법을 이용한 최적표고 결정 (Determination of the Optimal Height using the Simplex Algorithm in Network-RTK Surveying)

  • 이석배;어수창
    • 대한공간정보학회지
    • /
    • 제24권1호
    • /
    • pp.35-41
    • /
    • 2016
  • GNSS/Geoid 측위 기술은 GNSS측량으로 결정한 타원체고와 지오이드모델에서 계산된 지오이드고를 이용하여 측정위치의 정표고 결정을 가능하게 한다. 본 연구에서는 Network-RTK 방식에 의한 표고결정 적용성을 분석하기 위하여 연구대상지역의 수준점에 대한 Network-RTK 측량을 실시하였다. 그리고 우리나라의 KNGeoid13 지오이드모델을 적용하여 Network-RTK에 의한 표고를 산출하고 현장최적화를 적용한 계산결과와 적용하지 않은 계산결과를 비교하였다. 현장최적화 여부에 상관없이 모든 관측결과를 가지고 심플렉스법을 이용하여 최적표고값을 결정하였으며 이 결과를 국토지리정보원의 수준점 성과와 비교하였다. 연구결과 현장최적화를 적용하지 않은 Network-RTK 관측의 표고 정확도의 평가결과 평균오차값은 0.060m, 표준편차는 0.072m 이었으며, 현장최적화를 적용한 Network-RTK 관측 표고정확도의 평균오차값은 0.040m, 표준편차는 0.047m 이었다. 모든 관측값을 선형화에 사용하여 최적표고를 구한 경우 Network-RTK 측량은 0.033m의 정확도로 표고산출이 가능하다는 것을 알 수 있었다.

2-D 슬리트광 비젼 센서를 이용한 물체의 자세측정 (The Position Estimation of a Body Using 2-D Slit Light Vision Sensors)

  • 김정관;한명철
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.133-142
    • /
    • 1999
  • We introduce the algorithms of 2-D and 3-D position estimation using 2-D vision sensors. The sensors used in this research issue red laser slit light to the body. So, it is very convenient to obtain the coordinates of corner point or edge in sensor coordinate. Since the measured points are normally not fixed in the body coordinate, the additional conditions, that corner lines or edges are straight and fixed in the body coordinate, are used to find out the position and orientation of the body. In the case of 2-D motional body, we can find the solution analytically. But in the case of 3-D motional body, linearization technique and least mean squares method are used because of hard nonlinearity.

  • PDF

Gravity Modeling and Validation for High Accuracy Navigation Computation

  • Cho, Yun-Cheol;Shin, Yong-Jin;Park, Jeong-Hwa;Kim, Cheon-Joong;Choi, Kyung-Ryong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.64.1-64
    • /
    • 2001
  • Errors in inertial navigation system(INS) can be divided into two major groups which are system related errors and modeling errors due to approximation and linearization. Measurement noise, calibration, and alignment errors make up the first group, whereas the uncertainties in the gravity vector fall in the second category and are important error source for high quality INS, especially during high altitude and and/or long time missions, when the gravity errors tent to build up. The quality of a medium to high accuracy INS depends on the knowledge of the local gravity field. In this paper, the feasibility of improving airborns INS by use of more accurate gravity model is studied. To make consistent comparisons, WGS-84 parameters are used and ...

  • PDF