• 제목/요약/키워드: Linearity assessment

검색결과 78건 처리시간 0.018초

강사장교의 초기형상과 비선형성을 고려한 확률론적 구조안전성 평가 (Probabilistic Structural Safety Assessment Considering the Initial Shape and Non-linearity of Steel Cable-Stayed Bridges)

  • 방명석;한성호;이우상;이진옥
    • 한국안전학회지
    • /
    • 제25권3호
    • /
    • pp.91-99
    • /
    • 2010
  • In this study, the advanced numerical algorithm is developed which can performed the static and dynamic stochastic finite element analysis by considering the effect of uncertainties included in the member stiffness of steel cable-stayed bridges and seismic load. After conducting the linear and nonlinear initial shape analysis, the advanced numerical algorithm is the assessment tool which can performed structural the response analysis considering the static linearity and non-linearity of before or after induced intial tensile force, and examined the reliability assessment more efficiently. The verification of the developed numerical algorithm is evaluated by analyzing the regression analysis and coefficient of correlation using the direct monte carlo simulation. Also, the dynamic response characteristic and coefficient of variation of the steel cable-stayed bridge is calculated by considering the uncertainty of random variables using the developed numerical algorithm. In addition, the quantitative structural safety of the steel cable-stayed bridges is evaluated by conducting the reliability assessment based upon the dynamic stochastic finite element analysis result.

전동식 파워 스티어링을 위한 데이터 기반 결함 및 선형성 평가 모니터링 시스템의 설계 구현 (Design and Implementation of a Data-Driven Defect and Linearity Assessment Monitoring System for Electric Power Steering)

  • 왈레 알라비 라왈;키에 킴렁;한영선;김태경
    • 사물인터넷융복합논문지
    • /
    • 제9권2호
    • /
    • pp.61-69
    • /
    • 2023
  • 최근에는 환경에 대한 인식이 높아지면서 제조 차량에서 전자식 파워 스티어링(EPS)이 조향장치로 채택되는 사례가 증가하고 있다. EPS는 스티어링 파워 향상, 유압 호스 누출 제거 및 연료 소비 감소와 같은 수많은 이점을 제공하지만, 시스템이 움직임에 반응하게 만드는 센서를 요구한다. 이는, 센서의 선형 변동성을 유지하는 것이 스티어링 반응의 안정성에 필수적임을 의미한다. 따라서 EPS의 제어 품질을 보장하기 위해 내부 설계 특성의 변화에 대한 센서의 민감도, 결함 및 선형성을 평가하기 위한 신뢰성 있는 방법이 필요하다. 본 논문은 차량속도 구간 분할을 기반으로 EPS 구성요소 결함과 선형성을 분석하는 데이터 중심 결함 및 선형성 평가 모니터링 시스템을 제안한다. EPS 테스트 지그에서 수집된 데이터를 사용하여 모니터링 시스템의 성능을 검증하였으며, 그래픽 사용자 인터페이스(GUI)를 적용하여 시스템을 개선하였다. 개발된 시스템은 설계를 기반으로 0.99% 정확도의 결함 감지 및 가변적인 차량속도에서 선형성 평가를 효과적으로 수행하였다.

Establishment of analytical methods for allergenic compounds in mouthwashes and sanitary napkins by ultra-high-performance liquid chromatography with tandem mass spectrometry

  • Hee-Jung Sim;Hee-Jin Jeong;Yeong-In Lee;Yu-Jin Cho;Seung-Hoon Baek;Jong-Hwan Kim
    • 분석과학
    • /
    • 제36권2호
    • /
    • pp.89-98
    • /
    • 2023
  • Analytical methods for detecting atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes were developed using ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). UHPLC-MS/MS conditions were optimized for rapid, sensitive, and simultaneous analysis of the five allergenic compounds. The methods were validated by assessing their specificity, matrix effects, limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and precision. Good linearity was achieved with a determination coefficient of ≥0.99. The LOD and LOQ were 2.1-9.8 and 6.4-29.6 ng/g for sanitary napkins and 0.29-0.48 and 0.87-1.45 ng/mL for mouthwashes, respectively. The accuracy and precision were within an acceptable range according to the criteria reported in the European SANTE/11813/2017 guidelines (70-120 % recovery, <20 % relative standard deviation). Therefore, these methods can be used to analyze atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes.

측정시스템 평가에 관한 연구 (A Study for the Measurement System Assessment)

  • 백재욱
    • 품질경영학회지
    • /
    • 제26권4호
    • /
    • pp.124-142
    • /
    • 1998
  • It is essential to have a correct measurement system assessment to help improve process or quality. In this paper, we emphasize that a confidence interval a, pp.oach for the parameters of measurement error study and GR&R is crucial and a simple a, pp.oach for constructing them is presented. We also discuss on the issue of linearity of the gauge. Next, we try to reveal the relationship between measurement error and the process capability index. Finally some aspects of conducting the measuring experiment concerning the number of parts, number of measurements per part, and recommendations on how the experiment is to be performed will be considered.

  • PDF

CTOD 측정용 δ5 Clip Gage 설계 (Design of δ5 Clip Gage for CTOD Measurement)

  • 박태현;남승훈;김엄기
    • 대한기계학회논문집A
    • /
    • 제28권4호
    • /
    • pp.343-351
    • /
    • 2004
  • The flaw assessment method based on ${delta}_5$ parameter was recently proposed and put to the practical use. However: since it is almost impossible to measure the ${delta}_5$ by the existing commercial clip gager, we need to develope the specially designed gages which are suitable for that purpose. In this research, a double cantilever type ${delta}_5$ clip gage with the traveling distance of 4mm was developed by the finite element analysis and the construction of Wheatstone bridge circuit including strain gages. The linearity of developed ${delta}_5$ clip gage was evaluated by the MTS extensometer calibrator with the proper adapters which allow the 6s clip gage to sit on the calibrator. Consequently, the 6s clip gage revealed the good linearity between the output voltage and the traveling distance of gage.

임상보고 가능범위의 실증적 연구 (An Empirical Study of the Clinically Reportable Range in Clinical Chemistry)

  • 장상우;이상곤;최호성;송은영;박용원;이인애
    • 대한임상검사과학회지
    • /
    • 제39권1호
    • /
    • pp.31-36
    • /
    • 2007
  • The purpose of the clinically reportable range (CRR) in clinical chemistry is to estimate linearity in working range. The reportable range includes all results that may be reliably reported, and embraces two types of ranges: the analytical measurement range (AMR) is the range of analyte values that a method can directly measure on the specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. CAP and JCAHO require linearity on analyzers every six months. The clinically reportable range is the range of analyte values that a method can measure, allowing for specimen dilution, concentration, or other pretreatment used to extend the direct analytical measurement range. The AMR cannot exceed the manufacturer's limits. Establishing AMR is easily accomplished with Calibration Verification Assessment and experimental Linearity. For example: The manufacturer states that the limits of the AST on their instrument are 0-1100. The lowest level that could be verified is 2. The upper level is 1241. The verified AMR of the instrument is 2-1241. The lower limit of the range is 2, because that is the lowest level that could be verified by the laboratory. The laboratory could not use the manufacturer's lower limit of 2 because they have not proven that the instrument values below 2 are valid. The upper limit of the range is 1241, because although the lab has shown that the instrument is linear to 1241, the manufacturer does not make that claim. The laboratory needs to demonstrate the accuracy and precision of the analyzer, as well the validation of the patient AMR. Linearity requirements have been eliminated from the CLIA regulations and from the CAP inspection criteria, however, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. If a lab chooses to continue linearity studies, these studies must fully comply with the calibration/calibration verification requirements of CLIA and/or CAP. The results of lower limit and upper limit of clinically reportable range were total protein (2.1 - 79.9), albumin (1.3 - 39), total bilirubin (0.2 - 106.2), alkaline phosphatase (13 - 6928.2), aspartate aminotransferase (24 - 7446), alanine aminotransferase (13 - 6724.2), gamma glutamyl transpeptidase (16.64 - 9904.2), creatine kinase (15.26 - 4723.8), lactate dehydrogenase (127.66 - 13231.8), creatinine (0.4 - 129.6), blood urea nitrogen (8.67 - 925.8), uric acid (1.6 - 151.2), total cholesterol (48.52 - 3162), triglycerides (36.91 - 3367.8), glucose (31 - 4218), amylase (21 - 6694.2), calcium (3.1 - 118.2), inorganic phosphorus (1.11 - 108), HDL (11.74 - 666), NA (58.3 - 1800), K (1.0 - 69.6), CL (38 - 1230).

  • PDF

고속액체크로마토그래피를 이용한 항원충제 분석법 개발: 톨트라주릴 및 디클라주릴 (Development of high-performance liquid chromatography methods for the anticoccidials: toltrazuril and diclazuril)

  • 정경훈;정미영;박해철;아킬후세인;김대균;이광직;강정우
    • 대한수의학회지
    • /
    • 제57권4호
    • /
    • pp.223-226
    • /
    • 2017
  • This study was undertaken to develop new analytical methods for assessment of anticoccidials. High-performance liquid chromatography (HPLC) was found to be a fast, reliable, and practical method. The anticoccidials used in this experiment were toltrazuril and diclazuril, and the analysis factors were specificity, linearity, accuracy, repeatability, and intermediate precision. The linearity of each anticoccidial was better than 0.99, and the accuracies were 99.5% and 99.1% with relative SD of 0.5 and 0.4, respectively. To assess whether the developed HPLC method could be effectively applied, toltrazuril and diclazuril post-market veterinary products (five products) that are currently sold were tested. The results revealed no non-compliant items and the method was applied successfully. Therefore, the newly developed HPLC method for anticoccidial assessment described in this study may be useful as a reference method in the Korean Standards of Veterinary Pharmaceuticals for the analysis of toltrazuril and diclazuril.

대기 중 온실가스 농도 관측 장비 성능 비교 검증 (Assessment of Atmospheric Greenhouse Gas Concentration Equipment Performance)

  • 박채린;정수종;정승현;이정일;김인선;임철수
    • 대기
    • /
    • 제33권5호
    • /
    • pp.549-560
    • /
    • 2023
  • This study evaluates three distinct observation methods, CRDS, OA-ICOS, and OF-CEAS, in greenhouse gas monitoring equipment for atmospheric CO2 and CH4 concentrations. The assessment encompasses fundamental performance, high-concentration measurement accuracy, calibration methods, and the impact of atmospheric humidity on measurement accuracy. Results indicate that within a range of approximately 500 ppm, all three devices demonstrate high accuracy and linearity. However, beyond 1000 ppm, CO2 accuracy sharply declines (84%), emphasizing the need for caution when interpreting high-concentration CO2 data. An analysis of calibration methods reveals that both CO2 and CH4 measurements achieve high accuracy and linearity through 1-point calibration, suggesting that multi-point calibration is not imperative for precision. In dynamic atmospheric conditions with significant CO2 and CH4 concentration variations, a 1-point calibration suffices for reliable data (99% accuracy). The evaluation of humidity impact demonstrates that humidity removal devices significantly reduce air moisture levels, yet this has a negligible effect on dry CO2 concentrations (less than 0.5% relative error). All three observation method instruments, which have integrated humidity correction to calculate dry CO2 concentrations, exhibit minor sensitivity to humidity removal devices, implying that additional removal devices may not be essential. Consequently, this study offers valuable insights for comparing data from different measurement devices and provides crucial information to consider in the operation of monitoring sites.

풍력발전용 대형 복합재 회전날개의 구조시험 및 평가에 관한 연구 (Test and evaluation of a large scale composite rotor blade for wind turbine)

  • 정종철;장병섭;공창덕
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2001년도 제16회 학술발표회 논문초록집
    • /
    • pp.91-94
    • /
    • 2001
  • A structural test of the wind turbine rotor blade must be required to evaluate the uncertainty in design assessment due to use of material, design concepts, production processes and so on, and the possible impact on the structural integrity. In the full-scale static strength test, the measuring parameters are strain, displacements, loads, weight and the center of gravity. There are test equipments, measuring sensors, a test rig and fixtures to obtain measuring parameters. In order to simulate the aerodynamics load, the three-point loading method instead of the one-point loading method is applied. There is slightly some difference between the measured results and the predicted results with the reference fiber volume fraction of 60%. However, the agreement between the measured results and the predicted results with the actual fiber volume fraction of 52.5% is good. Even though a slightly non-linearity from 80% loading to 100% loading, a linear static solution is sufficient for the design purpose as the amount of the non-linearity is relatively small. Comparison between measured and predicted strain results at the maximum thickness positions of the blade profile for 0.236R(5.56m), 0.493R(11.59m) and 0.574R(13.43m), under 20%, 40%, 60%, 80% and 100% loadings for the upper part of the blade. The predicted values are in good agreement with the measured values.

  • PDF

물의 순환 학습 상황에서 초등학생의 시스템 사고의 특징 (Characteristics of Elementary Students' System Thinking in Learning of Water Cycle)

  • 김보민;맹승호
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제39권3호
    • /
    • pp.412-432
    • /
    • 2020
  • The purpose of this study is to explore the characteristics and the level of fourth grade elementary students' system thinking when they learn the unit of "Journey of Water" in terms of four key elements of system thinking such as understanding of the structure of a system, non-linearity and cyclic features, inter-relations and feedback between system properties, and temporal and invisible aspects of a system. Data included students' worksheets and their responses to a set of Likert-scaled and written assessment items on water cycle. The results showed that the level of students' system thinking did not have any hierarchy in relation to the key elements of water cycle system. In addition, the aspects of individual student's system thinking on its sub-elements were different from each other. Also, there were core ideas of system thinking which were intensively considered according to a given context to understand a complex systemic subject. When students learn water cycle, understanding of non-linearity and inter-relations were weaker compared with other key elements of system thinking. Therefore, if these two factors are taught in advance, it can promote understanding of whole system of water cycle.